Laserfiche WebLink
WATTSUN 5 . 6 1997 WA STATE ENERGY CODE COMPLIANCE REPORT i • 14-o1 <br /> FILE: C:\\WATTSUN5\\1240NORC.WS HOUSE ID: 1240 SPLIT <br /> **MILGARD VIN. SLID/DOOR STYLELINE U-0.510 73 .0 37 .2 <br /> Doors Wood 1 3/811 , solid flush U-0. 390 18 .0 7 .0 <br /> **METAL 1-3/4" URETHANE PEASE U-0.200 20. 0 4 .0 <br /> AG Wall R13 STD T1-11 U-0.088 190 16 .7 <br /> R13 STD Lap Wood U-0.082 560 45 .9 <br /> R13 STD T1-11 U-0.088 1168 102 .8 <br /> Ceiling R30 Clown Attic STD baffled U-0.036 1240 44 .6 <br /> Infiltration standard Air Sealing ACH-0.350 135_60ft3 ( 86 .9) <br /> Proposed UA 412 .2 <br /> Struc Mass Light Frame, Sheetrock walls M- 3 . 000 1695 5085 <br /> HEATING/COOLING/VENTILATING SYSTEMS <br /> PROPOSED <br /> Heating System Type: Gas Furnace <br /> Make: BY BUILDER <br /> Model: BY BUILDER/ <br /> System Efficiency: 80 % <br /> Modified Efficiency: 0 % <br /> Design ACH: 0 . 60 <br /> Design Load(at 44F dt) * 25345 Btu/hr <br /> Duct Losses( % Dsn Load) : 0 Btu/hr( 0%) <br /> Total Load: 25345 Btu/hr <br /> System Size(Output) : 38000 Btu/hr ( 150%) <br /> Average Annual Heat: *** MBtu <br /> Annual Cost: $ *** <br /> Ventilation System: Integrated Spot <br /> & Whole House <br /> Cooling System: <br /> SEER: 0 .0 ( ) <br /> Cooling Load(at 4F dt) : Btu/hr <br /> System Size(%Over) : tons(@125%) <br /> Annual Cool Requirement: kWh/yr <br /> Solar Access : Partially Shaded <br /> PROPOSED DUCT SYSTEM <br /> Location Avg Rvalue Surface Area <br /> SUPPLY Vented crawlspace R- 8.0 339 .0 ft2 <br /> RETURN Attic or garage R- 8 .0 67.8 ft2 <br /> Page 2 <br />