Kr— f �l�N F/PdE <br /> WATTSUN 5 . 6 1997 WA STATE ENERGY CODE COMPLIANCE REPORT <br /> T <br /> FILE: C:\\WATTSUN5\\1226NORC.WS HOUSE ID: 1226 SPLIT <br /> Site: Analyst: Ron Renard <br /> Jurisdiction: City of Everett <br /> ( ) - Utility: Gas �i <br /> Homeowner: NOR ;C House Type: Singl 25�'6 M <br /> a U D <br /> Floor Area: 166VIII <br /> VW <br /> Builder: Norco Weather Data: Seattle, WAJAN O ? -TT U <br /> ( 360) 629t9291E NW Climate Zone: 1 Cjpe(OS SCrvRp% <br /> The PROPOSED design *COMPLIES* with 1997 WA State Energy Code. <br /> REFERENCE PROPOSED <br /> COMPONENT PERFORMANCE 421 416 Btu/hr-F <br /> ENERGY BUDGET *** *** kWh/ft2-yr. <br /> REFERENCE DESIGN <br /> Reference <br /> Component Value X Area = UA <br /> On Grade Slab F-0 .540 92ft 49. 7 <br /> Floor U-0.041 714 29. 3 <br /> Glazing @158 U-0 .650 250.4 162. 7 <br /> Doors U-0 . 390 38.0 14. 8 <br /> AG Wall U-0 .062 1925 119.4 <br /> Ceiling, Attic U-0 . 036 1240 44.6 <br /> Infiltration ACH-0. 350 13560ft3( 6.9) <br /> Reference UA 420.5 <br /> PROPOSED DESIGN COMPONENTS <br /> Component Description Value X Area = UA <br /> On Grade Slab RIO 2 ' horizontal w/TB F-0 .540 92ft 49.7 <br /> Floor R19 euvented Joist 16oc U-0 .040 714 28.6 <br /> Glazing @148 **MILGARD VIN. XO STYLELINE U-0 .500 54 .0 27.0 <br /> **MILGARD VIN. FIXED STYLELINE U-0 .500 37 .5 18.8 <br /> **MILGARD VIN. S/H STYLELINE U-0. 500 61. 0 30.5 <br /> Items in parentheses not included in COMPONENT PERFORMANCE totals. <br /> ** Denotes non-standard values - check calculation of thermal value. <br /> -- Page 1 <br />