Laserfiche WebLink
.1991 • iCOMPLIANCF CHECKLIST <br /> ; COMPLIANCE <br /> rINSPEC <br /> TION IMPORTANT:Disregard topics that don't deserlbe your building or equipment.DO NO <br /> ED place checks In the two left columns. <br /> FINAL . , , r <br /> N/d p ®Airflow from habitable rooms to whole-house fan ensured by undercut doors or grills (VIAO,S.302.6.4) <br /> O O lar Loosefill Insulation OK H(S.502.1.4.5): <br /> ❑maximum telling slope_<_3 in 12 <br /> rg 30'of clear distance from top of bottom chord to underside of roof sheathing at the roof ridge. <br /> C:3 O @D6 trill black polyethylene ground cover, lapped 12' at Joints and to foundation wall <br /> 0 O Clearances shall meet listed minimums between Insulation and (8.502.1.4.3): <br /> ❑ chimney ❑ Non-10 rated recessed lights: 1/2"to combustables,3'to Insulation. <br /> O Ohatch shall be Insulated to required telling R-value and Is weatherstripped (S.502.1.4.4) <br /> C3 OgAtctlic access shall have wood dam or equivalent to retain loose fill insulation in attic (S.502.1.4.4) <br /> pII exterior doors (except 20 minute doors)shdll be weatherstripped (S.502.4.3). <br /> 0 � Service hot &cold water piping shall be Insulated to R-3(S. 503.11) <br /> p p S9rvlca recirculation hot water piping shall be Insulated to Table 5-12 levels. <br /> O hennostat provided for each HVAC system with range of 55-75' F.(heating) (S.503.8.1.1). <br /> C3 a Readily accessible,automatic er Manual means provided to restrict or shut-off Heating Input to each <br /> zone or floor during periods not requiring heat (S.503.8.3.1). <br /> O O r Controls for backup heat prohibit similtaneous operation of the primary system (S. 503.2.2(3)). <br /> p 2 Mechanical ventilation systems shall have proper timers, and/or switches (S.302.3). <br /> O Mechanical ventilation ducts shall have insulation i R-4 in unconditioned spaces(VIAO,S.302.5) <br /> p p Mechanical supply ducts in conditioned spaces shall have i R-4 insulation(VIAO,S.302.5) <br /> O O upply duds shall have volume dampers,or the equivalent,to balance system(S.503.6). <br /> Q p Supply and return air ducts shall have sealed dud Joints in unconditioned spaces (S. 503.10.2). <br /> p p HVAC plenums,supply,and return air duds shall have R-8 Insulation(fable 5-11,All options) <br /> oezdr p Electric water heater(s)shall have(S.504.2.1,504.3,504.4) : <br /> ❑separate power • • shut-off ❑ 1987 NAECA Lable on tank <br /> ❑ noncompressible R10 pad(unheated spaces only) ❑ Temperature setting s 120 F. <br /> O e Showers and lavatories shall limit flow toe. 3.0 gallons/minute (S. 504.8.1). <br /> p p Swimming pool(s) (S.504.5) shall have: <br /> ❑readily accessible ON/OFF switch(pump, heater) ❑ Pool cover ❑Piping Insulated to S.503.11 <br /> O O r Fireplace(s) (VIAO,S.402.3)shall have: <br /> ❑ 6 square Inch combustion air supplydud w/operable damper, directly connected to the fire box <br /> ❑Tight fitting glass or metal doors;or flue draft Induction fan. ❑ Tight fitting flue damper. <br /> O O 2 Solid fuel burning appliance(s) (VIAO, S.402.2) shall have: <br /> ❑ Tight fitting glass or metal doors <br /> ❑ Outside combustion alr source directly connected to the fire box <br /> ❑ Exception: Non-direct,4'diameter, dampered, combustion air source: allowed only for(1) new stove <br /> installations in existing homes where obstructions preclude direct combustion air,or(2) Central <br /> heating systems located in unheated spaces. <br /> C3 0 631 Three month,etched track,radon monhor, printed instructions, and an Information sheet shall be <br /> supplied by the builder to each single family dwelling and to each ground floor unit of muni-famlly dwellings <br /> (VIAO,S.502.2.1). <br /> WSEC Final phase requirements: <br /> Inspected by <br /> Date- <br /> Page 6 of 6 <br />