Laserfiche WebLink
VC- 21 / / Replace or repair, ca, and paint windows and doors a. .aceseary. In rooms with <br /> openable windows at least one must be operative. <br /> VC- 22 !f7 Install a 3E4=non.�djuatahjo tecopocaLuee�nd pressure-re}se£�ralve on hot water• sank. <br /> �7(T aad.,D 3/4" discharge line to putside or to an interior drain. Rating of valve shall <br /> not be greater than working pressure rating of water tank. <br /> VC-23 /Y/ / / (a) Replace all deteriorated rotted or damaged wood foundation and framing members, <br /> 7' including poets, plates, beams and joists in underfloor area, with sound material . <br /> N wood to remain within 6" of ground. <br /> (b) Replace all skirting and other wood in contact with the ground with material <br /> resistant to rot and infestation. Finish all exposed now or repaired work to match <br /> exterior. No wood to remain within 6" of ground. <br /> VC-24 / / /—/ (a) Install new gutters, elbows and downspouts on main building. Apply primer and <br /> Two coats of exterior paint to match existing finish. <br /> / / (b) Instal. elbows for downspouts and splash blocks to carry roof water at least <br /> three feet away from foundation. <br /> VC-25 i-1 Install plastic laminate or equal to kitchen counter top and back splash after first <br /> replacing any damaged or rotted underlay. <br /> VC- 26 / / Install at least four 8"xl4" galvanized hardware -loth screened crawl space area vents <br /> of V mesh (one near each corner) to adequately vent crawl space area. <br /> Note: Metal louvered nail on vents are not acceptable. <br /> VC- 27 /-/ Install an acceptable vapor barrier ground cover over entire crawl apace area. <br /> VC- 28 / / Crawl apace shall be graded and sloped to prevent ponding of seepage water. Install <br /> drain the in gravel bed connected to suitable outfall to provide positive drainage <br /> away from dwelling. Cover entire crawl space with acceptable vapor barrier. <br /> VC-29 i-1 Install 1/8" screened hooded roof or 1/8" screened louvereaable vents to provide <br /> positive cross ventilation of attic space. <br /> VC- 30 / / Submit evidence that the leased / / gas furnace burner /—/ hat water tank has been <br /> purchased from the utility company or has boon replaced with new equipment and to now <br /> part of the realty. (Leased equipment not acceptable). <br /> VC- 31 / / Install new gas or electric gallon water heater with 3/4" non-adjustable tempera- <br /> ture and pressure relief valve with discharge line to outside or interior drain. <br /> Leased equipment not acceptable. <br /> VC- 32 Install a new forced a1r, wall, baseboard or other heating system adequate to heat all <br /> �i finished rooms to 70 Fahrenheit. Submit heat loss cal.culationa and Installation plan <br /> for approval prior to it rtallation. Space or room heaters are not acceptable in <br /> dwellings of this type. If electric heat is installed, adequate insulation and wiring <br /> and service panel are required to meet minimum housing standards of authority having <br /> jurisdiction. <br /> VC-33 i-1 Sand and refinish hardwood floors in the following rooms: <br /> Painted fir floors may be repainted. NOTE: The Installation of carpeting and cushion' <br /> meeting UM-44b standards in these areas is an acceptable alternate method of satisfying <br /> this condition. <br /> VC 34 /% /% Replace / / Repair garage door to function properly. <br /> VC- 35 / / /_/ (a) The FNA value is based on a lot size of <br /> (b) Submit copy of correct legal description including lot dimensions. <br /> VC-36 /% /% (a) Since a portion of the land offered as security in deemed to be ineligible <br /> excess land, the Deed of Trust or Mortgage shall cover only the following <br /> _ parcel which is eligible: <br /> (b) Tho portion of land to be deleted consists of: <br /> IC- 37 /% Submit evidence from the local authority having jurisdiction that the subject property <br /> has been connected to the %/ public sa7n�itary newer system, /_/ public water system. <br />