Laserfiche WebLink
VC-21 / ./'Replace or /repair, caulk and paint winiows and doors as necessary. In ronm5 with <br /> openable windows at least one must be operative. <br /> VC- 22 1-7. Install a 3/4" non-adjustable temperature and pressure relief valve on hot water tnnk <br /> and a 3/4" discharge line to outside or to an interior drain. Rating of valve shall <br /> not be grenter than working pressure ratin, of water tank. <br /> VC-23 / / / (a) Replace all deteriorated rotted or damaged wood foundation and framing members, <br /> Including posts, plates, beams and joists in underfloor area, with sound material. <br /> No wood to remain within 6" of ground. <br /> %/ (b) Replace all skirting and other wood in contact with the ground with material <br /> resistant to rot and infestation. Finish all exposed new or repaired work to match <br /> - exterior. No wood to remain within 6" of ground. <br /> VC- [4 / / / / (a) Install new gutters, elbows and downspouts on main building. Apply primer and <br /> two coats of exterior paint to match existing finish. <br /> (b) Install elbows for downspouts and splash blocks to carry roof water at least <br /> three feet away from foundation. <br /> VC-25 / / Install plastic laminate or equal to kitchen counter top and back splash after first <br /> replacing any damaged or rotted underlay. <br /> VC-26 / / Install at least four 811x14" galvanized hardware cloth screened crawl space area vents <br /> of V mesh (one near each corner) to adequately vent crawl space area. <br /> Note: Metal louvered nail on vents are not acceptable. <br /> VC- 27 / / Install an acceptable vapor barrier gr and cover over entire ceawl space area. <br /> VC- 28 j_/ Crawl space shall be graded and sloped to prevent ponding of seepage water. Insta'.1 <br /> drain tile in gavel bed connected to suitable outfall to provide positive drainage <br /> away from dwelling. Cover entire crawl space with acceptable vapor barrier. <br /> VC- 29 /% Install 1/8" screened hooded roof or 1/8" screened lauveredable vents to provide <br /> positive cross ventilation of attic space. <br /> vC- 30 / / Submit evidence that the leaned / gas furnace burner / / hot water tank has been <br /> purchased from the utility company or has been replaced with new equipment and to now <br /> part of the realty. (Leased equipment not acceptable). <br /> VC-31 / / Install new gas or electric gallon water heater with 3/4" non-adjustable tempeta- <br /> ture and pressure relief valve with discharge line to outside or interior drain. <br /> Leased equipment not acceptable. <br /> VC- 32 / / Install a new forced air, wall, baseboard or other heating system adequate to heat all <br /> finished rooms- to 70o Fahrenheit. Submit heat loan calculations and installation pian <br /> for approval prior to installation. Space or room heaters are not acceptable in <br /> dwellings of this type. If electric heat is installed, adequate insulation and wiring <br /> and service panel are required to meet minimum housing standards of authority having <br /> jurisdiction. <br /> VC-33 / / Sand and refinish hardwood floors in the following rooms: <br /> Painted fir floors may be repainted. NOTE: The installation of carpeting and cushion' <br /> meeting UM-44b standards in these areas is an acceptable alternate method of satisfying <br /> this couditton. <br /> VC 34 /% / / Replace / / Repair garage door to function properly. <br /> VC-35 / / / / (a) The FNA value is based on a lot size of <br /> (b) Submit copy of correct legal description including let dimensions. <br /> VC.- 30 / / / / (a) Since a portion of the land offered as security is deemed to be ineligible <br /> excess land, the Deed of Trust or Mortgage shall cover only the following <br /> parcel which is eligible: <br /> (b) The portion of land to be deleted consiota of: <br /> VC-37 / / Submit evidence from the local authority having jurisdiction that the subject property <br /> has been connected to the %/ public sanitary sewer system, %/ public voter system. <br /> ' - AC1'O 696.049 <br />