My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1111 80TH ST SW NATURAL FACTORS 2016-01-01 MF Import
>
Address Records
>
80TH ST SW
>
1111
>
NATURAL FACTORS
>
1111 80TH ST SW NATURAL FACTORS 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/18/2017 7:43:48 PM
Creation date
4/18/2017 7:43:17 PM
Metadata
Fields
Template:
Address Document
Street Name
80TH ST SW
Street Number
1111
Tenant Name
NATURAL FACTORS
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
238
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1897 EDITION <br /> TABLE 10-6C <br /> TRANSMISSION COEFFICIENTS'(U)'FORWOOD AND STEEL DOORS <br /> .Btu/h•ft <br /> .. , a•..p. . <br /> ... ,, ._.., ...... . i <br /> Nominal „ No Wood Matal <br /> Door Description Storm Storm Storm <br /> Thickness. _._-.._. . . ._.- Door. .. Doorc Doord <br /> Inches <br /> Wood Doors' _ <br /> 1.3/8 Panel door with 7/16 inch pansle - 0.57 0.33 0.37 <br /> 1-3/8 Hollow core Flush door 0.47 . 0.30 0.32 . i <br /> ... <br /> 1-3/8 Solid core flush door � "-•- - ......_ 0.39 0.26 0.28 <br /> 1-3/4 Panel door with 7/16 inch panele - 0.57 0.33 0.36 <br /> 1.3/4 Hollow core flush door - 0.46 0.29 0.32 <br /> 1-3/4 Panel door with 3/4 inch panels. 0.40 0.27 0.29 <br /> 1-3/4 . Panel door with 1-1/8 inch els' - " 0.39 0.26 0.28 <br /> 1-3/4 Solid core flush door - " 0.33 0.28 0.25 <br /> 2.1/4 Solid core flush door 0.27 0.20 0.21 <br /> Steel Doors' <br /> 1-3/4 Fiberglass or mineral wool core with steel stiffeners, 0.60 - - <br /> uo thermal breakf <br /> 1-3/4 Pacer honevcomb core without thermal break' 0.56 <br /> 1-?14 Solid urethane foam core without thermal break' 0.40 - - <br /> I-3/4 Solid fire rated mineral fiberboard core 0.38 --- <br /> without thermal break' <br /> 1-3/4 Polystyrene core without thermal break 0.35 <br /> (18 gage commercial steel)' <br /> 1-3/4 Polyurethane core without thermal break 0.29 --- <br /> (18 gage commercial steel)' <br /> 1-3/4 Polyurethane core without thermal break 0.29 --- - <br /> (24 gage commercial steel)' <br /> 1-3/4 Polyurethane core with thermal break&wood perimeter 0.20 - <br /> 24 gage commercial steep' <br /> 1-3/4 1 Solid urethane foam core with thermal break 0.19 0.16 0.17 <br /> NOTE: All U-factors for exterior doors in this table are for doors with no glazing, except for the storm doors which are in <br /> addition to the main exterior door. Any glazing area in exterior doors should be included with the appropriate glass type and <br /> analyzed. Interpolation and moderate extrapolation are permitted for door thicknesses other than those specified. <br /> a. Values are based on a nominal 32 by 80 in. door size with no glazing. <br /> b. Outside air conditions: 15 mph wihd speed, OOF air temperature; inside air conditions: natural convection, 70OF air <br /> temperature. <br /> c. Values for wood storm door are for approximately 50% glass area. <br /> d. Values for metal storm door are for any percent glass area. <br /> e. 55 Fo panel area. <br /> f. ASTM C 236 hotbox data on a nominal 3 by 7 ft door size with no glazing. <br /> The U-factors in Table 6C are for exterior wood and steel doors. The values given for wood doors were calculated, and those for <br /> steel doors were taken from hotbox tests(Sabine et al. 1975: Yellot 1965) or from manufacturer's test reports. An outdoor <br /> surface conductance of 6.0 Btu/h,ft -OF was used, and the indoor surface conductance was taken as 1.4 Bru/h•fr•'F for vertica <br /> surfaces with horizontal beat flow. All values given are for exterior doors without glazing. If an exterior door contains giving, <br />' refer to Table 10-6D. <br /> Effective 7/01198 61 <br />
The URL can be used to link to this page
Your browser does not support the video tag.