My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1111 80TH ST SW NATURAL FACTORS 2016-01-01 MF Import
>
Address Records
>
80TH ST SW
>
1111
>
NATURAL FACTORS
>
1111 80TH ST SW NATURAL FACTORS 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/18/2017 7:43:48 PM
Creation date
4/18/2017 7:43:17 PM
Metadata
Fields
Template:
Address Document
Street Name
80TH ST SW
Street Number
1111
Tenant Name
NATURAL FACTORS
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
238
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1994 Washington Slate Nonresidential Energy Code Compliance Form <br /> BLdIding Permit Planr� 'Chlaicktist '4�'-,:__- ENV-CHK <br /> ilrve w..4+.pian Sui. Compurce form. /Prir r W. <br /> Prolepl Address Dale <br /> 1111 64reet 40 vve# WA oz/o9 /oo <br /> The following Information is necessary to check a building permit application for compliance with the building envelope requirements In the <br /> Washington State Nonresidential Energy Code. <br /> Arpbcabiaty Code Location Building Department <br /> (circle one) Secllon Com rent Information Required on Plans Notes <br /> GENERAL REQUIREMENTS Sections 1301-1314 <br /> 1301 1 Scope Unconditioned spaces identified on plans II allowed <br /> 1302 Space real type <br /> es no dL3: Electric resistance -- _ <br /> yW no n.a. Other Indicate on plans that electric resistance heat is not allowed -r- 1 <br /> es no AM 1310.2 Semi-healed spaces Semi-healed spaces Identified on plans if allowed <br /> 1711 Insulation <br /> jfp no n.a. 1311.1 Insul.Installation Indicate densities and clearances T-f <br /> yes--no n.a 1311.2 Roof/ceiling insul. Indicate R-value on roof sections for attics end other roofs; -r-•1 <br /> Indicate clearances for attic Insulation; <br /> Indicate baffles If eave vents Installed; <br /> Indicate lace stapling of faced baits <br /> rs' no n.a. 1771.3 Wall insulation Indicate R-value on vrall sections; <br /> Indicate face stapling of fazed bans; 7-- <br /> Indicate above grade enenor Insulation is protected; -T-r/ <br /> Indicate loose-fill core Insulation for masonry walls as recess; <br /> Indicate Lest capacity of masonry Walls <br /> if masonry option is used or it credit taken in ENVSTD; <br /> yes no aT 1311.4 Floor insulation Indicate R-value on floor sections; <br /> Indicate substantial contact woh surface; <br /> Indicate supports not more than 24-o.c.; <br /> Indicate that insulation does not block , <br /> airflow through foundation vents <br /> no n.a. 1311.5 Slab-on-grade noor Indicate R-value on wall section or foundation tlelad; <br /> Indicate slab Insulation extends down vertically 24-from top; T'f <br /> Indicate above grade edenor insulation is protected <br /> Yes no ifi.a. 1311.6 Radiant floor Indicate R-value on Wall section or foundation detail; <br /> Indicate slab insulation extends Gown vertically 36 from the lop; <br /> Indicate above grade exterior insulation is protected; <br /> Indicate insulation also under entire slab where r 'd.by Official <br /> YSs' no n.a. 1312 Glazing and doors Provide calculation of glazing area(including both vertical 7.1 <br /> vertical and overhead)as percent of gross wall area <br /> ff no n a 1712.1 1.1-factors Indicate glazing and door U-factors on glazing and door <br /> schedule(provide area-weighted calculations as necessary); "r Z <br /> Indicate If values are NFRC or default if values are default <br /> then specify frame type,glazing layers,gapwldth.Iovl-e <br /> coatings,gas fillings <br /> es no he 1312.2 SMGC&SC Indicate glazing solar heal gain coefficient or shading 7%1 <br /> coefficient on glazing schedule(provide area-weighted <br /> calculations as necessary) <br /> 1313 Moisture control <br /> 6e7j>no n.a. 1313.1 Vapor retarders Indicate var`or retarders on warm side <br /> yIW no n.a 1313.2 Rooffceil ng vap ret. Indicate vapor retarder on root section. <br /> Indicate vap retard with sealed seams for non-wood strut. T-/ <br /> is no n a 1313.3 Wall vapor retarder Indicate vapor retarder on wall section 7--y <br /> Yes no 4T.A. 13134 Floor vaDor retarder Indicate vapor retarder on floor section <br /> s no n a. 1313.5 CravAs ace vaD.rel. Indicate six mil black Dol lhvlene overlapped 12"on round <br /> 1314 Ae k. e <br /> !s`no n.a. 1314.1 Bldgenvel.seating 11ndicale sealing,caulking,gasketing,and weatherstripping <br /> 3 no n a 13142 Glazm /door sealingIndicale"atherstmo in T-f <br /> s no 4t-b- 13143 Assembas ducts Indicate sealing.Caulkino and gaskeling <br /> PRESCRIPTIVE/COMPONENT PERFORMANCE Sections 1320-23 or 1330-34 <br /> a no Envelope Sum. Form Completed and attayhed. <br /> Provide component performance worksheet if necessary <br /> Provide ENVSTD screen I output it necessary <br /> nciIs circled or any question, Provide exp avatlon' <br />