My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1118 80TH ST SW BASE FILE 2018-01-02 MF Import
>
Address Records
>
80TH ST SW
>
1118
>
BASE FILE
>
1118 80TH ST SW BASE FILE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/11/2019 3:00:16 PM
Creation date
4/18/2017 8:39:16 PM
Metadata
Fields
Template:
Address Document
Street Name
80TH ST SW
Street Number
1118
Tenant Name
BASE FILE
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
387
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
" I <br /> April 27, 1971 <br /> CITY OF <br /> Pepsi Cola Bottling Co. everett <br /> 3231 Broadway _.+. -.L{ . xf. ..., <br /> Everett, Washington 98201 L.L.L•*. ..-,\=TOY <br /> v.xe <br /> Re: New Building, 1118 80th Place, Everett, Washington <br /> Gentlemen: <br /> The following requirements of the Uniform Building Code must be met <br /> before a building permit is to be issued for the balance of the <br /> construction. <br /> 1. Justify the total cost of the building. <br /> 2. Provide solid core door with self closer to workshop area. <br /> o'ection 503 and Table 5 B. <br /> 3. Change s•ring of door to liquid and sugar concentrate area to t: <br /> swing in line of egress, or change to double acting doors <br /> with 200 square inches of view panel in each door. Sec. 3303 (b). <br /> 4. Protect columns in area separation wall with 2-hour protection. <br /> 505 (c) . Three layers of 5/8" X rated gypsut3 required. (Table <br /> 43 A, item 25) <br /> 5. Area separation wall shall be two-hours (two layers of 5/8" X <br /> rated gypsum board each side) with 111 hour openings. Sec. 505 (c) <br /> 6. Door openings require B-label doors, frames and hardware, self- <br /> closing with fusible links. Sec. 4306 (b) and (e) (100 Sq. In. <br /> of wire glass each door) Windows not allowed in 2-hour wall. <br /> 7. Toilet rooms shall have hard, smooth, non-absorbent floors and <br /> 4'0" high wainscot. Sec. 1711 (a) <br /> 8. Submit Technical information regarding plastics, and conform to <br /> Chapter 52. <br /> 9. Provide exhaust system for garage area. Sec. 1105 <br /> 10. Provide wet stand pipes. Section 3804 <br /> 11. Provide fire curtains in space between floor and suspended <br /> ceilQings 1000 sq. feet maximum. Sec. 2517 (e) <br /> 12. Change detail of second floor framing into 2-hour wall for 2-hour <br /> protection. <br /> 13. Provide 2-hout wall to roof at wall between vending service and <br /> bottling area. <br /> 14. Storage room live loads shall comply with Table 23 A. <br /> 15. Drawings do not agree with specifications regarding Sec. 2314. <br /> 16. Provide lateral support for masonry walls in accord with 2419 (b) 2, <br /> 2417 (c) and Table 24 I. <br />
The URL can be used to link to this page
Your browser does not support the video tag.