2003 Washington State Nonresidantial Energy Code Compliance Form
<br /> • •
<br /> 2007 wpm.Mon aced lmvauaenMl Eh*VY Code Cmnpunce Fema Ransea.MY 2opM
<br /> Prescriptive Spaces Occupancy: OWarehouses.storage areas oraucraft storage hangers *)Other
<br /> Qualification Checklist Lighting Fixtures: ❑ Check hem it at least 95%or fixtures in the space meet all four criteria:
<br /> Nola If occupancy type b-Other and biter,
<br /> anawar is checked.the number of fli In 1.Fixtures aro fluorescent,non-lensed,with only one or two lamps,and
<br /> I"space is not Imiaed by Code Clearly
<br /> Indicate Inose spaces on plans If Trot 2.Lamps am T-1,T-2,T-4,T-5,T-6,T-0 3.Lamps are 5-50 Watts,and
<br /> qualrFed,do LPA Calculations 4.Ballasts em electronic ballasts 5.Exit"a<5 wattsmxture
<br /> 6.Screw-In compact fluorescent fub• at do not quality
<br /> TABLE 15-1 Unit Lighting Power Allowance LPA
<br /> Use LPA Use LPA
<br /> /s /s
<br /> Painting,welding,carpenFry,machine shops 2.3 Police and fire stations 1.5
<br /> Barber shops,beauty shops 2.0 Atria atriums) 1.0
<br /> Hotel baniquellconferencelexhiblUcin hall 2.0 Assembly spaces'.auditoriums.gymnasia',heatere 1.0
<br /> Laboratories 2 0 Group R-1 common areas 1.0
<br /> Aimrefl MPai hangars 1.5 Process Plants 1.0
<br /> Cafeterias fast food establishments' 1.5 Ressurantaftiamb 1.0
<br /> Factories workshops,handling areas 1.5 Locker and/or shower facilities 0.8
<br /> Gas stations auto repair sho s 1.5 Warehouses",storage areas 0.5
<br /> Institutions 1.5 Aircraft storage hen ars 0.4
<br /> Libraries 1.5 Retail�- mtsn banking 1.5
<br /> Nursing homes and holegmotel guest morns 1.5 Parking garages See Section
<br /> 1532
<br /> Who[ Ad stores(pallet rack shelving) 1.5
<br /> Mall conceuries 1.4 Plans Submitted for Common Areas Only'
<br /> Schools buildings(Group E occupancy only), 1.35 Mein floor building lobbies (except mall 1.2
<br /> school classrooms day caro centers concourses
<br /> Laundries 1.3 Common areas,comdom,toilet facilities and 0.8
<br /> washrooms elevator lobbies_
<br /> Office buildings,,orficeladministretrm areas In 1.2
<br /> facilities of other use types(Including but not limited
<br /> to schools i hospitals,institutions,museums,banks,
<br /> cl niches) __
<br /> Footnotes for Table 15.1
<br /> 1) In cases in which a general use and a specific use arc listed,the specific me shall apply.In cases In which a use is not
<br /> mentioned specifically,the Unit Power Allowance shall be determined by the building official This determination shall be based
<br /> upon the most comparable use specified In the taNe See Section 1512 for exempt areas.
<br /> 2) The watts per square fool may be increased.by two percent per foot of calling height above twenty feet,unless specifically
<br /> directed otherwise by subsequent footnotes.
<br /> 3) Watts per square fool of room may be increased by two percent per fool of ceiling height above twelve(eel,
<br /> 4) For all other spaces.such es seating and common areas,use the Unit Light Power Allowance for n1sa,ibly.
<br /> 5) Watts per square foot of room may be Increased by Iwu percent per foot of ceiling height above nine feet
<br /> 6) Includes pump area under canopy.
<br /> 7) In cases in which a lighting plan Is submitted for only a portion of a floor,a Unit Lighting Power Allowance of 1.35 may be used
<br /> for usable office floor area and 0.80 watts per square foot shall be used for the common areas,which may Include elevator
<br /> space,lobby area and rest rooms.Common areas,as herein defined do not include mall concourses.
<br /> 8) For the fire engine roan,the Unit Lighting Power Allowance is 1.0 watts per square foot.
<br /> 9) For Indoor sport tournament courts with adjacent spectator seating,the Unit Lighting Power Allowance for the court area is 2.6
<br /> watts per square foot.
<br /> 10) Display window illumination installed within 2 feel of the window,lighting for free-standing display where the lighting moves with
<br /> the display,and building showcase illumination where the lighting Is enclosed within the showcase are exempt.
<br /> An additional 1.5 wlfl'of merchandise display luminaires are exempt provided that they comply with all three of the following.
<br /> a) Ionated on ceiling-mounted track or directly on or recessed Into the ceiling Itself(not on the wall).
<br /> b) adjustable In bath the horizontal and vertical axes(vertical axis only is acceptable for fluorescent and other fixtures with
<br /> two points of track attachment.
<br /> c) fitted with tungsten halogen,fluorescent,or high Intensity discharge lamps.
<br /> This additional lighting power is allowed only it the lighting is actually installed
<br /> 1 t) Provided that a floor plan,indicating nick location and height,is submitted,the square twinge for a warehouse may be
<br /> defined,for computing the interior Unh Lighting Power Allowance,as the floor area not covered by racks plus the vertical face
<br /> area(access side only)of the racks.The height allowance defined in footnote 2 applies only to the floor area not covered by
<br /> racks.
<br />
|