Laserfiche WebLink
Code Compliance Form <br />2" w1.f•y I Sta. Nar.e.mei.sl Lre, CON. Camy.n:.. Form. <br />Project Address clra, 7u.te o <br />Date 4/7/2008 <br />Space Heat Type <br />O Electric resistance Oa All other <br />For Building Department Use <br />G1 azi ng Area as% gross exterior wall area <br />Prop. <br />45.0% Max.Targel <br />Concrete/Masonry Option <br />Oves CO No <br />Notes'. If glazing area exceeds maximum allowed in Table, then calculate adjusted areas on back (over). <br />Building Component <br />Proposed UA <br />Target UA <br />List components by assembly ID R page is <br />U-fader x Area A • UA U x A <br />U-factor x Area A • UA U x A <br />U= 'Ian ID <br />0.550 <br />U. Plan ID. <br />Glazing % Electric Resist. Other Heating <br />3 <br />U• Plan I0. <br />0-30% 0.40 0.55 <br />y <br />U. Plan ID: <br />>3045% see note above 0A5 <br />> (7 <br />U= Plan ID <br />U= Plan ID. <br />U= Plan ID. <br />D <br />U= Plan ID <br />0.100 <br />U- Plan ID. <br />Glazing % Electric Resist. Other Heating <br />U. Plan ID: <br />0-30% 0.6 0.7 <br />O <br />U= Plan ID <br />>30-45% see note above 0.6 <br />RY <br />ya <br />U. Plan ID. <br />t <br />g <br />U. PIan ID. <br />c_ <br />U. Plan 10. <br />O <br />U= Plai ID. <br />0.700 <br />C <br />U=0.500 Plan ID wood <br />0.500 84.0 42.0 <br />0.600 84.0 50.4 <br />n $ <br />U= Plan ID <br />Electric Resist. Other Heating <br />O <br />U= Plan ID. <br />0.30 0.60 <br />• t <br />R= Plan ID'. <br />0.036 <br />Electric Resist. Other Heating <br />R• Plan ID. <br />c <br />R= Plan ID. <br />0.031 0.036 <br />y <br />R. 30.0 Plan ID 9.tt. on r-ear <br />0.031 1210.0 44.8 <br />0.046 1306.0 60.1 <br />Electric Resist. Other Heating <br />R= 30.0 Plan ID Ova <br />0.076 96.0 7.3 <br />R= Plan ID <br />0.034 0.046 <br />R. 19.0 PIan ID `rtl, 16oc 0.109 459.0 50.0 <br />0.109 906.0 90.0 <br />R-21.0 PIan IDFrtl, 24. tat 0.090 447.0 40.2 <br />•• <br />'m <br />R- Plan ID. <br />•• <br />3 <br />R= Plan ID <br />Electric Resist. Olhei Healing <br />6 <br />R- Plan ID. <br />Frame-Wd 0.062 0.062 <br />$ <br />R- Plan ID <br />Frame-MII 0.062 0.109 <br />O <br />R= Plan ID <br />Mass Wall" 0.15 0.15 <br />"Note sum of Target Areas here should equal Target Opaque Wall Area (see back) <br />++ see mass wall Criteria <br />R= Plan ID <br />c = <br />R- Plan ID <br />Electric Resist. Other Heating <br />R= Plan ID <br />Int Ins 0.062 0.062 <br />Note if insulated to levels required for opaque walls. list above with opaque walls <br />Ext Ins 0.07 0.07 <br />R= Plan ID <br />0.056 <br />Electric Resist. Other Heating <br />So c <br />R= Plan ID <br />R= Plan ID <br />0.029 0.056 <br />R= Plan ID <br />i y T <br />R= Plan ID Unrn.uLtw <br />0.730 110.c 80.3 <br />0.540 110.0 59.4 <br />a <br />R= Plan ID. <br />Electric Resist. Other Heating <br />9 <br />7 0 <br />IR= <br />R= Plan ID <br />F-0.541 F•0.56 <br />Plan ID <br />(see Table 13-1 for radiant floor values) <br />'For CMU walls, indicate core insulation material. Totals <br />2406.0 <br />264.6 <br />Totals <br />2606.0 <br />268.6 <br />To comply: 1) Proposed Total UA shall not exceed Target Total UA. <br />2) Proposed Total Area shall equal Target Total Area. <br />