Laserfiche WebLink
I <br />FRANKLIN <br />ENGINEERING <br />MECHANICAL CONSULTING <br />March 27, 2006 <br />625 4th Avenue PH 425 827-3324 <br />5uitr.. 02 FAX 425 827-6252 <br />Kirklard. WA 98033 hvacOfrankbneng.corn <br />RE: Integrated Systems Group <br />526 Commerce Center, Ste D <br />Everett, WA <br />9660-5 - D $a <br />ENVELOPE `'UMMARY <br />Heated space applies to Office space. <br />Doors (Opaque): Word, U=0.5 default. <br />Other Roof Type 1: P.-30 batt insulation on vented T-bar ceiling. U = 0.037, calculated. <br />Other Roof Type 2 (Restrooms): R-30 batt insulation on GWB ceiling. U=0.076, <br />calculated. <br />Wall Type 1 (Opaque, Office/Warehouse): Metal studs, 6", 24" cc with R-21 batt <br />insulation, U = 0.085 default. <br />Wall Type 2 (Opaque, Demising): Metal studs, 6", 19" cc with R-21 batt insulation, <br />U = 0.097 default. <br />Slab on Grade: No Insulation, F=0.73, default. <br />Please note that these values are minimum insulation requirement, for code compliance. <br />Higher insulation values may be installed. <br />SHGC = Solar Heat Gain Coefficient <br />