My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1420 80TH ST SW PPG IND 2018-01-02 MF Import
>
Address Records
>
80TH ST SW
>
1420
>
PPG IND
>
1420 80TH ST SW PPG IND 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2022 12:01:08 PM
Creation date
4/19/2017 12:15:23 AM
Metadata
Fields
Template:
Address Document
Street Name
80TH ST SW
Street Number
1420
Tenant Name
PPG IND
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
55
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NNE <br />.D�x <br />AH(n <br />y E m <br />KH0 <br />z <br />i0� <br />Hag <br />n• Go <br />yz y3 <br />g� <br />H <br />cl t7 En <br />00En <br />U) <br />June 4, 1992 <br />Mr. LynneMalik <br />P.P.G. Industries <br />555 Strander <br />Seattle, Washington 98188 <br />RE: Owner: P.P.G., Industries/P.M. Northwest <br />Job Address: 1420-80th Street S.W., Suite F <br />Plan Check No.: 92/36818 <br />Dear Mr. Malik: <br />In response to your application for a construction Permit, your plans have been examined and <br />you are advised that the issuance of a permit is being withheld for the reasons listed below. <br />These comments address building issues only, additional revisions or additions may be <br />required by other departments (such as Utilities, Planning or Fire). All references refer to the <br />1988 Uniform Building Code an Washington State Energy Code unless stated otherwise. <br />1. Please provide a complete racking plan indicating the following: <br />01�jA. Rack and aisle dimensions <br />l7' B. Rack Heights <br />C. Building access required by Section 8 1. 109 Uniform Fire Code (UFC) <br />D. Eight (8) foot minimum aisle width required by Table 81.105 UFC <br />E. Smoke and heat vents required by Table 81.105 UFC and described in Section <br />81.107 UFC <br />F. 1-1/2 inch small hose connections required by Table 81.105 UFC <br />G. Smoke detection system required by Table 81.105 UFC <br />In order for the processing of your application to continue, it will be necessary to provide the <br />�) Building Department with two complete new sets of drawings reflecting the corrections <br />requested. <br />Upon re -submittal of the drawings, your application will be given priority and plan review <br />recommence. <br />All required submittals shall be of sufficient detail and contain sufficient information to ensure <br />.. that the proposed structure will be constructed in compliance with all adopted codes. <br />�rz <br />Sin <br />Mfrineer/Building <br />tp tate E <br />1smxIlmak <br />CITY OF EVERETT• 3200 Cedar Street • Everett, WA 98201 • (206) 259 8800 • Fax (206) 259.8882 -*1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.