Laserfiche WebLink
The following table shows the total release rate at each elevation interval: <br />0.01, <br />0.003 c.f.s. <br />""** 0.003 c.f.s. <br />0.50' <br />0.019 c.fs <br />"**" <br />0.019 c.f.s. <br />1.00, <br />0.027 c.f.s. <br />*""* <br />0.027 c.f.s. <br />1.50' <br />0.033 c.f.s. <br />**"* <br />0.033 c.f.s. <br />2.00' <br />0.038 c.f.s. <br />*"*" <br />0.038 c.f.s. <br />2.50' <br />0.043 cTs. <br />"""* <br />0.043 c.f.s. <br />2.51' <br />0.043 C.I.S. <br />0.39 c.f.s. <br />0.433 cTs. <br />3.00' <br />0.047 cTs. <br />2.76 c.f.s. <br />2.807 c.f.s. <br />The following table shows volumes at the different elevation intervals: <br />0.01, <br />IM <br />22 cubic feet <br />0.50, <br />1,187 cubic feet <br />1.00, <br />2,522 cubic feet _ <br />i.50' <br />4,012 cubic feet <br />2 00' <br />5,665 cubic feet <br />2.50' <br />7,490 cubic feet <br />2.50' <br />71500 cubic feet <br />2.50' <br />9,635 cubic feet <br />By entering the storage volumes versus the release rates into the Hydra "RES" command the <br />detention system may be accurately modeled. The following table shows the allowable release rates <br />for the site versus the actual release rates as determined by the I lydra Analysis (link 11 pg.s 18, 20, <br />& 22). <br />2 year 0.04 O's. 0.04 c.fs. 6,484 cubic feet 1 9,272 cubic feet <br />10 year 0.28 c.f.s. 0.19 c.f.s. 7,487 cubic feet 10,706 cubic feet <br />100 year 0.63 c.f.s. 0.62 c.f.s. 7,606 cubic feet 10,876 cubic feet <br />Note: The totals in the "Actual Pond Storage" represent the actual storage available to allow for a <br />43% correction factor. <br />10 <br />