F R A N K L I N <br />ENGINEERING <br />.June 5, 2007 <br />RE: Diebold, Inc. <br />80"' Street Venture <br />830 801' St SW, Ste 100 <br />Everett. WA <br />625 4th Avtnuc <br />5wtc 202 <br />Korkland, WA 98033 <br />Heated space applies to Office space. <br />PH 42: <br />FAX 42r. <br />hvac0fr,z- <br />RG706e - c77 <br />ENVELOPE SUMMARY <br />CITY OF EVERETT <br />REVIEWED FOR PERMIT <br />Vertical Glazing: Double pane, 1 /2" space Air, low-e10'0', fixed. Or certified tested <br />assembly per NFRC. U=0.55, default. SHGC=0.45. <br />Doors (Opaque): Insulated metal, U-0.60, default. <br />Other Roof Type 1: R-30 bait insulation on T-bar ceiling. U = 0.037, calculated. <br />Other Roof Type 2 (Restrooms): R-30 batt insulation on GWB ceiling. U=0.076, <br />calculated. <br />Wall Type 1 (Opaque, Exterior, Floor to 8'-6" AFF): Concrete, min. 6" thick, furred with <br />metal studs, 3-1/2", 24" oc with R-15 bast insulation, U=0.10, calculated. <br />Wall Type 2 (Opaque, Exterior, 8'-6" AFF to structure above): Concrete, min. 6" thick, <br />with R-21 batt insulation stickpinned to concrete, U=0.049 calculated. <br />Wall Type 3 (Opaque, Spandrel glass): Glass as described above furred with metal studs, <br />min. 3-1/2", 24" oc with R-15 bait insulation, U=0.09 calculated. <br />Wall Type 4 (Opaque, Office/Warehouse): Metal studs, min. 5-1/2", 16" oc with R-21 <br />batt insulation, U=0.097 default. <br />