Laserfiche WebLink
2006 Wt.,nmoton State Nonresidential Enerov Code <br />Protect Address 7YM valvaa <br />Date 7/28/2007 <br />Space I[eat Type <br />10 El( otic resistance Qa All otter <br />For Building Department Use <br />Glazi ng Area as% gross exterior wall area <br />20.4%Prop. <br />1 45. 0% Max.Target <br />Concrete/Masonry Option <br />O Yes I) No <br />Notes: If glazing area exceeds maximum allowed In Table, then calculate adjusted areas on back (over). <br />Building Component <br />Proposed UA <br />Target UA <br />List components by assembly ID 8 page 8 <br />U-factor x Area A • UA U x A <br />U-factor x Area A • UA W x A <br />Ua0.550 Plan to Dbl ft. Lon -a <br />0.550 364.5 200.5 <br />0.510 364.5 200.5 <br />Glazing % Electric Reslsl. Other Heating <br />U. Plan to: <br />U. Plan to <br />0.30% 0.40 0.55 <br />U. Plan 10 <br />-30.45% see note above 0.45 <br />> <br />U. Plan ID: <br />U. Plan ID. <br />U. Plan ID: <br />U. Plan10: <br />1' ion <br />U. Plan ID: <br />Glazing % Llec•rit Resist. Other Hearing <br />U. Plan ID. <br />0.30% 0.6 0.7 <br />U. Plan ID: <br />>30.45% see note above 0.6 <br />45 <br />U. Plan to. <br />U. Plan ID. <br />U. Plan ID. <br />0.700 <br />U. Plan ID: <br />C <br />Ua0.500 Plan ID Mood <br />0.300 42.0 21.0 <br />0.600 42.0 25.2 <br />Electric Resist. Other Hearing <br />R <br />U• Plan ID: <br />3 <br />U. Plan to: <br />0.60 0.60 <br />R• Plan to: <br />0.036 <br />Electric Resist Other Heating <br />Q <br />R• Plan ID. <br />6 <br />c e <br />R• Plan ID: <br />0,031 0.036 <br />Ra 36.0 Plan 10 Batts an T-bar <br />0.029 2018.0 56.5 <br />0.046 2210.0 101.1 <br />8 <br />Ra 30.0 Plan ID Batts on axis <br />0.076 192.0 14.6 <br />Electric Resist. Omer Heating <br />Ra Plan to <br />0.034 0,046 <br />Ra15.0 Plan ID Nrred cane <br />0.101 562.0 56.6 <br />0.109 1316.5 150.3 <br />R• 21. 0 Plan ID Mtl, 24m <br />0.090 916.5 13.5 <br />• • <br />ffi <br />Ra Plan ID: <br />'• <br />3 <br />R= Plan ID: <br />Electric Resirt. Omer Heating <br />v <br />R= Plan ID: <br />Frame-Wd 0.062 0.062 <br />$ <br />R= Plan to: <br />Frame-MII 0.062 0.109 <br />0 <br />R= Plan ID: <br />Mass Wall' 0.15 0.15 <br />"Note aunt of Target Areas here should equal <br />Target 0 a u 'Nall Area (see back) <br />•+ see mass wait Criteria <br />Ra Plan ID. <br />Electric Resist. Other Healing <br />s S <br />R• Plan ID. <br />1 <br />R• Plan ID <br />Int Ins 0.062 0.062 <br />Note'. If insulated to levels required for o aque walls, list above wart opaque walls <br />Ext Ins 0.07 0.07 <br />Ra Plan 10: <br />0.056 <br />Electric Resist. Other Healing <br />Ra Plan ID. <br />_ <br />Ra Plan ID. <br />0.029 0.056 <br />R• Plan ID <br />Ra Plan ID Unansulated <br />0.130 210.0 153.3 <br />0.540 210.0 113.4 <br />L <br />R• Plan ID: <br />Electric Resist. Other Heating <br />It <br />R• Plan ID: <br />F•0.54 Fa0.54 <br />Ra Plan ID: <br />(see Table 13-1 for radiant floor values) <br />'For CMU walls. indicate care insulation material. Totals <br />4205.0 <br />578.1 <br />Totals <br />4205.0 <br />591.0 <br />To comply: 1) Proposed Total UA shall not oxcedd Target Total UA. <br />2) Proposod Total Area shall equal Target Total Aroa. <br />