Laserfiche WebLink
Project Info <br />Project Address <br />Innovt•ch T.I. <br />Dale 4/6/2006 <br />832 Both at. Be (building C) <br />For Building Department Use <br />1 i0 <br />Everett. WA 98203 <br />Applicant Name: <br />Jesse Johnson for Innovtech <br />Applicant Address: <br />130 Lakudlis, Suite 250, Seattle MA 98322 <br />Applicant Phone: <br />206-325-2553 <br />Project Description <br />❑ New Building ❑ Addition ❑ Alteration ❑Plans Included <br />Refer to WSEC Section 1513 for controls and commissioning requirements. <br />Compliance Option <br />Prescriptive @) Lighting Power Allowance O Systums Analysis <br />(Sao Qualification Checklist (over). Indicate Prescriptive 6 LPA spaces clearly on plans.! <br />Alteration Exceptions I <br />I(check appropriate box - sec. 1132 3) 1 <br />❑ No changes are being made to the lighting <br />❑ Less than 60% of the fixtures new. Installed wattage not Increased, & space use not changed. <br />Maximum Allowed Lighting Wattage (Interior) <br />Location <br />(noor/room no.) <br />Occupancy Description <br />Allowed <br />Watts per N2 i• <br />Area In N2 <br />Allowed x Area <br />First oor <br />office - a <br />1.00 <br />3120.0 <br />3120.0 <br />con oor <br />Office - a <br />1.00 <br />2920.0 <br />2920.0 <br />From Table 15.1 (over) - document all exceptions on form LTG-LPA Total Allowed Watts 6040.0 <br />Notes: <br />1. Use manufacturer's listed maximum Input wattage. For hard -wired ballasts only, <br />the default table in the NREC Technical Reference Manual may also be used <br />2. Include exit lights unless less than 5 watts per fixture. <br />Proposed Lighting Wattage (Interior) 3. List all fixtures. For exempt lighting, not exception and leave WanslFixture blank. <br />Location <br />(floorlroom no.) <br />Fixture Description <br />Number of <br />Fixtures <br />Wafts/ <br />Fixture <br />Watts <br />Proposed <br />Office <br />2rx lay -in fluorescent fixture <br />60 <br />88.0 <br />5280.0' <br />Offices <br />11.4 lay -in fluorescent fixture <br />7 <br />67.0 <br />469.0 <br />Total Proposed Walls may not exceed Total Allowed Watts for Interior <br />Maximum Allowed Lighting Wattage Exterior <br />Total Proposed Watts 5749.01 <br />Location <br />Description <br />Allowed Watts <br />per N2 or per If <br />Area In N` <br />(or It for perimeter) <br />Allowed Wafts <br />x NI (or x Ip <br />Covered Parking <br />(standard paint) <br />0.2 W/N2 <br />Covered Parking <br />(reflective paint) <br />0.3 W/N2 <br />Open Parking <br />0.2 WIN' <br />Outdoor Areas <br />0 2 W/N2 <br />Bldg. (by facade)' <br />0.25 W/fII <br />Bldg. (by penm)' 1 <br />7.5 WAf <br />1. Choose either the facade area or the perimeter method, but not both) Total Allowed Wafts <br />Use, nu0r nsrw maxnhuni rnpui waiiai fur nxmras wnn hard -warm uauams uniy, <br />Proposed Lighting Wattage (Exterior) the defa-llt table In the NREC Technical Reference Manual may also be used. <br />Location <br />Fixture Description <br />Number of <br />Fixtures <br />I wattsF1 <br />Fixture <br />Walls <br />Proposed <br />Total Proposed Watts may not exceed Total Allowed Watts for Exterior <br />Total Proposed Wattsl l <br />&X� <br />