Laserfiche WebLink
FRANKLIN <br />ENGINEERING <br />MECHANICAL CONSULTING <br />April 4, 2006 <br />Er`Qe97 Conte - <br />RV & oy- d! / <br />625 4th Avenue PH 425 827-3324 <br />5uitc 202 FAX 425 827-6252 <br />Kirkland. WA 98033 hvacCMfrank hneng.com <br />ENVELOPE SUMMARY <br />RE: Innovatech <br />80" St Venture, Bldg C <br />Everett, WA <br />Heated space applies to Office space. <br />Vertical Glazing Type 1 (Exterior): U=0.55, SHGC=0.45. Unlabeled glazing - 1/2" <br />space Air, low-e 1 "' fixed, default. Or certified tested assembly per NFRC. <br />Vertical Glazing Type 2 (Relite to Warehouse): U=0.90, SHGC=exempt. Unlabeled <br />glazing - double pane, fixed, default. Or certified tested assembly per NFRC. <br />Doors (Opaque): Wood, U =0.50, default. <br />Other Roof Type 1: R-30 bait insulation on vented T-bar ceiling. U=0.037, calculated. <br />Other Roof Type 2 (Restrooms): R-30 bait insulation in metal framing on GWB ceiling. <br />U=0.076, calculated. <br />Wall Type 1 (Opaque, Exterior, Floor to 8'-6" AFF): Concrete, min. 6" thick, furred with <br />metal studs, 3-1i2% 24" oc with R-13 bait insulation, U=0.11, calculated. <br />Wall Type 2 (Opaque, Exterior, 8'-6" AFF to 12'-0" AFF): Concrete, min. 6" thick, with <br />R-13 bait insulation stickpinned to concrete, U=0.08 calculated. <br />Wall Type 3 (Opaque, Warehouse): Metal studs, min. 5-1/2", 16" oc with R-19 bait <br />insulation, U=0.10 default. <br />ba� <br />