Laserfiche WebLink
SECTION III —SYSTEM COMPONENTS <br /> UL EX. 3470 ULC CEx747 Page 3-7 <br /> 10-1-02 REV.4 <br /> DETECTORS CLIP-ON STYLE-PART NO.56837 AND 56838 <br /> The detector consists of three basic components:the bracket, link- <br /> age, and fusible link. (Fusible links are not included and must be <br /> ordered separately.)The bracket holds the entire assembly to the LINKAGE FUSIBLE <br /> FUSI <br /> BLE <br /> mounting surface.The linkage is used to support the fusible link. LINK <br /> BRACKET <br /> The fusible link is designed to separate at a specific temperature <br /> and release the wire rope,thereby actuating the regulated release <br /> mechanism. 000,5, <br /> There are three styles of detectors available:the clip-on style,the HINGED STYLE-PART NO 15373 AND 15375 <br /> hinged style, and the scissor style. <br /> The clip-on style allows the wire rope to be strung completely O <br /> through the detection system conduit and brackets first and the / <br /> detector linkage assemblies are then clipped on later. LINKAGE FUSIBLE <br /> The hinged style detector requires the wire rope to be strung to the LINK <br /> detector bracket, and then"threaded"through the linkage assem- <br /> bly before continuing to the next detector bracket. <br /> The scissor style allows the wire rope to be strung completely 000158 <br /> through the detection system conduit and brackets first and the <br /> detector linkage assemblies are then clipped on later. sclssoR STYLE-PART No a173sa AND a173ss <br /> BRACKET <br /> Each style of detector consists of two types of assemblies: / <br /> The Terminal Detector (Part No. 56838, 15375, or 417368) LINKAGE <br /> includes a test link and is placed last in a series of detectors.This <br /> detector is sometimes referred to as the end-of-line detector and l <br /> is thus named because it is at the point at which the wire rope"ter- FUSIBLE <br /> minates,"or is anchored at the detector bracket.Only one terminal LINK <br /> detector is required per detection system. <br /> The Series Detector(Part No. 56837, 15373, or 417369) is any 000159 <br /> detector located in-line between the regulated release assembly FIGURE 21 <br /> and the terminal detector. PULLEY ELBOWS <br /> When using Part No. 56837 and 56838 style detectors, a total of There are two types of pulley elbows used to change the direction <br /> 12 detectors can be in one detection system: 11 series detectors, of the wire rope by 90°.Ansul recommends for temperatures not in <br /> Part No.56837 and 1 terminal detector, Part No.56838. excess of 700°F(371 °C).Part No.415670 has socket ends with <br /> When using Part No. 15373 and 15375 style detectors, a total of 5 set screws for 1/2 in.conduit, and Part No.423250 has compres- <br /> detectors can be in one detection system:4 series detectors, Part sion ring ends also for 1/2 in. conduit. Pulley elbows must be <br /> No. 15373 and 1 terminal detector, Part No. 15375. ordered in quantities of 50 as Shipping Assembly Part No.415671 <br /> When using Part No.417368 and 417369 style detectors, a total (socket end type)and Part No.423251 (compression end type). <br /> of 15 detectors can be in one detection system: 14 series detec- PART NO.415670 PART NO.423250 <br /> tors, Part No.417369 and 1 terminal detector, Part No.417368. 771 <br /> O <br /> 000,60 <br /> FIGURE 22 <br /> __1// ,*- <br />