Laserfiche WebLink
P.kR:IPET -2 FOP OF EIISFINC A('S EXISTING OUTDOOR CONDENSING UNIT <br /> CI'-I CC-2 Cl.--4 U-J TOP OF NF.R'ci--3 <br /> r-- TAG MODEL# HP REFRIGERANT VOLTAGE WEIGHT <br /> I I r--� r--� r--� I I r - - � _ <br /> 3'6 <br /> ROOFLIN"E a to m <br /> Freezer LPLO150EPP 71h R-404A 208-230/1/60 320 V <br /> NEW OUTDOOR CONDENSING UNIT .c E N <br /> m� „s <br /> ('1"-3 G O m w i $ <br /> WEIGHT E o <br /> 11,01 <br /> 12'8.75" 16'2" TAG MODEL# HP REFRIGERANT VOLTAGE (lb) C e m x > �S <br /> C <br /> U cn WN a U a <br /> CU-3 208-230/1/60 <br /> Freezer <br /> MOH014L6 1% R404A MCA=15 170 <br /> PARAPET WALL HEIGHT=3'6" MOPD=20 ? m 0 <br /> EQUIPMENT NOTES: _ W <br /> EAST ELEVATION Nor'fo Scale 1. CU-3 to be mounted&secured per code on new 4x4 pressure treated wood sleepers. z pc 0 <br /> 2. Reconnect to existing refrigerant line set with new outdoor unit and new indoor unit. _= z a <br /> e= <br /> 3. Existing condensing unit's height is 26.69"tall(on 4x4 sleepers)&weighs 320 lb. W~ y <br /> New condensing unit's height is 20.75"tall(on 4x4 sleepers)&weighs 170 lb. <br /> Parapets wall height is 42"tall on roof. . a <br /> SCOPE OF WORK Ir Z 0~ " y <br /> O N Q J NX <br /> D <br /> CL CL(l l a <br /> • Remove and dispose of existing upright frozen food freezer with remote rooftop <br /> condensing unit(CU-3)&replace with new."Like-for-Like"Replacement. <br /> • Reconnect to refrigerant piping through existing roof penetration. <br /> CT Secure new rooftopremote condensing unit to roof per code(/See Detail <br /> E\IS ILNG ' g p l �• <br /> ' Equipment start-up&test. C <br /> RooF <br /> HATCH Parcel #: 28041200304700 d' Y <br /> Legal Description: Section 12 Township 28 Range 04 Quarter SW-CAAP 30FT N OF SE COR <br /> SW1/4 SD SEC 12 TH N89*17 35W ALG N BDY IN BEVERLY PK-MUK RD(CASINO RD)3351T TH CONT N89*3517W O O <br /> ON SD N BDY LN 162.90FT M/L TAP 165FT E OF W LN OF El/2 SEl/4 SWI/4 SD SEC 12TH NOO*55 58E PLT W LN <br /> SD SEI/4 SWI/4 DIST LOFT TO NEW NLY R/W MGN CASINO RD(BEVERLY PK-MUK RD)&TPB TH CONT N00*55 <br /> AC-2 58E 152.04FT TH S89*3517E 13.83FT TH SOO*55 58W 2OFT TH S89*3517E 127.77FT TO THE NEW WLY R/W bIGN I Q <br /> EXISTING �36�-8^+ HARDESON RD TH 502*46 02W ALG SD WLY R/W MGN 95.76FT TH S29*19 56W ALG SD WLY R/W MGN 11.18FT LJJ <br /> 0 00 <br /> TAP OF CRV TH ALG CRV TO R HAVG RAD OF 22.50FT C/A OF 87*38 41 CTR WH BEARS N87*13 38W ARC DIST Y <br /> 34.42FT TO NEW NLY R/W NIGN OF CASINO RD(BEVERLY PK-MUK RD)TH S63*50 49W ALG SD NLY R/W MGN Z <br /> 11.18FT TH N89*3517VV ALG SD NLY R/W MGN 100.98FT TO TPB(AKA PAR B COE SP REC LIND AFN 8212060203) J O 0 <br /> E\IST G EXC WLY&SLY R/W TO COE BY SWD REC UND AFN 830106020-4 � � Z_ � <br /> /a < Z <br /> CII-2 #�OX3� WOOD SCREWS �7 w N ¢ z <br /> EXISTING TYPICAL 41UNIT CU—3 �""� W U 2 <br /> REPLACEExISTING N Wcc <br /> N <br /> CLT-1 CODE\SING NIT (CU-3 METAL 4"x4" PRESSURETREATED L ` <br /> N <br /> u0.O- W S <br /> EXISTING "LIKE-FOR-LIKE" FLASHING ROOF SLEEPERS.BOLTED TO ROOF � Q <br /> W #10 x 3 1/4 WOOD SCREWS Z <br /> SECURE TO ROOF W O W <br /> AS PER CODE. > <br /> W WLU <br /> W a w <br /> CONDENSING UNIT ANCHORING DETAIL ROOF LINE a <br /> CI-3 LLJ <br /> AC-1 <br /> EVSTLNG <br /> 101-01, <br /> _ �;..�:� REVISIONS <br /> SATALITE �� a <br /> MAY 16 2017 <br /> o <br /> CITY OF EVERETT 1s-1°•� ;moi - <br /> DRAWN SAM ALMO <br /> Permit S2f4�e� I <br /> 5� <br /> DATE <br /> 5/15/2017 <br /> STOREFRONT CU_3 CONTENTS <br /> ____._ Joe# S29 <br /> ;1TY OF EVERETT N WSW <br /> E��IFD FOR PERMIT TVE <br /> s <br /> SHEET NUMBER <br /> ROOFTOP HVACPLAN 4 <br /> Scale: 1/8"= V-o" VICINITY MAP <br />