r <br /> Interior • • Space-By-Space LTG-INT-SPACE <br /> 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised Jan 2014 <br /> Project Address Underwood Gartland-Building A Date 5/18/2015 <br /> Lighting Alterations, Renovations & Building Additions For Building Department Use <br /> O Less than 60% O 60%or more O Stand alone O Addition <br /> Notes: <br /> a.Lighting fixtures in a building addition may comply as a stand alone project,or they may be <br /> combined with the overall existing bldg lighting to demonstrate compliance. Refer to C101.4.3. <br /> b. For retrofits and building additions,provide Space Types and gross interior areas in the <br /> Maximum Allowed Lighting table.If a builidng addition will comply as combined with the overall <br /> existing builidng,include all applicable existing Space Types and gross interior areas. <br /> c.Document new fixtures and all existing to remain fixtures in the Proposed Lighting table. <br /> d. If less than 60%of existing fixtures will be replaced,provide total existing lighting wattage <br /> (prior to retrofit)in the space provided in the Maximum Allowed Lighting table. <br /> Maximum Allowed Lighting Wattage <br /> Location(plan#, Allowed Uross interior Wafts Allowed <br /> room#) Space Type' Watts per ft2 Area in ft2 (watts/ft2 x area) <br /> Warehouse Warehouse:Medium/bulky material 0.58 180051 104430 <br /> Speculative Office-Open plan 0.98 20000 19600 <br /> Electrical/mechanical 0.95 563 535 <br /> Atrium** Enter Height: <br /> Existing Lighting Enter Exist.Watts: <br /> Retail Display Allowance from LTG-INT-DISPLAY <br /> ` Select Table C405.5.2(2)category from drop down menu. Area Allowed Watts <br /> " For atriums,indicate height.Allowed wattage for first 40 feet is 0.03 W/ft.ht., Total 200614 124564 <br /> above 40 feet is 0.02 W/ft.ht. <br /> Proposed Lighting Wattage <br /> Location(plan It, Number of Watts/ Watts <br /> room#) Fixture Description— Fixtures Fixture Proposed <br /> Warehouse Hibay 2'x4'4-lamp T5 Fluorescent 241 <br /> Warehouse Hibay2'x4'6-IampT5Fluorescent 160 362 57920 <br /> Speculative 2x4 Fluorescent(speculative only) 200 104 20800 <br /> Elec&Riser Rm 4 104 416 <br /> Retail Display Lighting from LTG-INT-DISPLAY <br /> Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watt 79136 <br /> Include existing to remain lighting fixtures and exempt lighting equipment per notes below. <br /> Notes: <br /> 1.Include ALL proposed lighting fixtures. <br /> 2.For proposed Fixture Description,indicate fixture type,lamp type(e.g. T-8),number of lamps in the fixture,and ballast type(if included).For <br /> track lighting,list the length of the track(in feet)in addition to the fixture,lamp,and ballast information. <br /> 3.For proposed Watts/Fixture,use manufacturer's listed maximum input wattage of the fixture(not simply the lamp wattage)and other criteria <br /> as specified in Section C405.5.1.For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, <br /> or as applicable,the wattage of current limiting devices of the transformer. For low voltage track lighting list the transformer rated wattage. <br /> 4. For lighting equipment eligible for exemption per C405.5.1,note exception number and leave Watts/Fixture blank. <br /> 5.Document existing to remain fixtures in Proposed Lighting table in the same manner as new fixtures.Identify as existing in fixture description. <br /> 6. If#NA appears in Retail Display cells,information on LTG-INT-DISPLAY is incomplete. <br /> Interior Lighting Power Allowance COMPLIES <br />