My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6101 ASSOCIATED BLVD BASE FILE 2017-06-05
>
Address Records
>
ASSOCIATED BLVD
>
6101
>
BASE FILE
>
6101 ASSOCIATED BLVD BASE FILE 2017-06-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2017 1:50:29 PM
Creation date
5/15/2017 10:33:04 AM
Metadata
Fields
Template:
Address Document
Street Name
ASSOCIATED BLVD
Street Number
6101
Tenant Name
BASE FILE
Notes
GEOTECHNICAL REPORT INCLUDED
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
308
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r <br /> Interior • • Space-By-Space LTG-INT-SPACE <br /> 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised Jan 2014 <br /> Project Address Underwood Gartland-Building A Date 5/18/2015 <br /> Lighting Alterations, Renovations & Building Additions For Building Department Use <br /> O Less than 60% O 60%or more O Stand alone O Addition <br /> Notes: <br /> a.Lighting fixtures in a building addition may comply as a stand alone project,or they may be <br /> combined with the overall existing bldg lighting to demonstrate compliance. Refer to C101.4.3. <br /> b. For retrofits and building additions,provide Space Types and gross interior areas in the <br /> Maximum Allowed Lighting table.If a builidng addition will comply as combined with the overall <br /> existing builidng,include all applicable existing Space Types and gross interior areas. <br /> c.Document new fixtures and all existing to remain fixtures in the Proposed Lighting table. <br /> d. If less than 60%of existing fixtures will be replaced,provide total existing lighting wattage <br /> (prior to retrofit)in the space provided in the Maximum Allowed Lighting table. <br /> Maximum Allowed Lighting Wattage <br /> Location(plan#, Allowed Uross interior Wafts Allowed <br /> room#) Space Type' Watts per ft2 Area in ft2 (watts/ft2 x area) <br /> Warehouse Warehouse:Medium/bulky material 0.58 180051 104430 <br /> Speculative Office-Open plan 0.98 20000 19600 <br /> Electrical/mechanical 0.95 563 535 <br /> Atrium** Enter Height: <br /> Existing Lighting Enter Exist.Watts: <br /> Retail Display Allowance from LTG-INT-DISPLAY <br /> ` Select Table C405.5.2(2)category from drop down menu. Area Allowed Watts <br /> " For atriums,indicate height.Allowed wattage for first 40 feet is 0.03 W/ft.ht., Total 200614 124564 <br /> above 40 feet is 0.02 W/ft.ht. <br /> Proposed Lighting Wattage <br /> Location(plan It, Number of Watts/ Watts <br /> room#) Fixture Description— Fixtures Fixture Proposed <br /> Warehouse Hibay 2'x4'4-lamp T5 Fluorescent 241 <br /> Warehouse Hibay2'x4'6-IampT5Fluorescent 160 362 57920 <br /> Speculative 2x4 Fluorescent(speculative only) 200 104 20800 <br /> Elec&Riser Rm 4 104 416 <br /> Retail Display Lighting from LTG-INT-DISPLAY <br /> Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watt 79136 <br /> Include existing to remain lighting fixtures and exempt lighting equipment per notes below. <br /> Notes: <br /> 1.Include ALL proposed lighting fixtures. <br /> 2.For proposed Fixture Description,indicate fixture type,lamp type(e.g. T-8),number of lamps in the fixture,and ballast type(if included).For <br /> track lighting,list the length of the track(in feet)in addition to the fixture,lamp,and ballast information. <br /> 3.For proposed Watts/Fixture,use manufacturer's listed maximum input wattage of the fixture(not simply the lamp wattage)and other criteria <br /> as specified in Section C405.5.1.For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, <br /> or as applicable,the wattage of current limiting devices of the transformer. For low voltage track lighting list the transformer rated wattage. <br /> 4. For lighting equipment eligible for exemption per C405.5.1,note exception number and leave Watts/Fixture blank. <br /> 5.Document existing to remain fixtures in Proposed Lighting table in the same manner as new fixtures.Identify as existing in fixture description. <br /> 6. If#NA appears in Retail Display cells,information on LTG-INT-DISPLAY is incomplete. <br /> Interior Lighting Power Allowance COMPLIES <br />
The URL can be used to link to this page
Your browser does not support the video tag.