Laserfiche WebLink
600 University Street,Suite 610 <br /> "'Iq Seattle,WA 98101 <br /> (206)622-0222 Fax(206)622-4764 <br /> m o f f o t t & n i c h o l WW W.moi-iattnichol cum <br /> SITE VISIT MEMO <br /> To: Erik Gerking(POE) <br /> From: Stuart Stringer, PE(M&N) <br /> Date: 21 April 2015 <br /> Subject: Port of Everett ESY Bulkhead Pile Cap Rebar Inspection <br /> M&N Job No.: 8057-03 <br /> Date of Visit: 21 April 2015 <br /> Location: Port of Everett Central Marina <br /> Purpose: Observe Progress of Construction & Check Pile Cap Rebar <br /> Time: 11:00am—12:00pm <br /> Weather: Cloudy <br /> Personnel in Attendance: <br /> Stuart Stringer (Moffatt& Nichol) <br /> Summary: <br /> Stuart Stringer from Moffatt & Nichol arrived onsite at approx. 11:00am to look at the pile cap rebar for <br /> the fifth and final pile cap concrete pour.This pour will consist of the Segment B curb between WP3 and <br /> WP4.The extent of the pour is shown in Figure 1. <br /> At the time of the site visit the Contractor was mostly complete with the rebar installation, and <br /> formwork setup. All of the rebar appeared to be placed in accordance with the contract documents. The <br /> only remaining items were for the Contractor to clean the rebar of concrete splatter(from the previous <br /> concrete pour) and remove debris from the formwork. Figures 2 through 4 show the progress of the pile <br /> cap construction. <br />