Laserfiche WebLink
Thompson Fire Damage Repair March 7, 2016 2 of 7 <br /> ELEVATIONS, BUILDING HEIGHT, FOOTPRINT, EXTENT OF IMPERVIOUS SURFACES,AND UTILITIES <br /> REMAIN UNCHANGED. <br /> PROJECT NOTES: <br /> GENERAL <br /> 1. THESE GENERAL NOTES APPLY, UNLESS SPECIFICALLY NOTED OTHERWISE. <br /> 2. ALL CONSTRUCTION,TESTING AND INSPECTING SHALL CONFORM TO THE BUILDING CODE REFERENCED BELOW. <br /> 3. STANDARDS REFERENCED IN THESE NOTES SHALL BE THE LATEST EDITION, UNLESS OTHERWISE NOTED. <br /> 4. THE NOTES AND D1-TAILS ON THE DRAWINGS SHALL TAKE PRECEDENCE OVER THE GENERAL NOTES AND TYPICAL <br /> DETAILS. <br /> 5. DETAILS SHALL BE APPLIED TO EVERY LIKE CONDITION WHETHER OR NOT THEY ARE REFERENCED IN EVERY <br /> INSTANCE. FOR CONDITIONS NOT SPECIFICALLY SHOWN, PROVIDE ENGINEER WITH WRITTEN REQUEST FOR <br /> CLARIFICATION.(RFI). <br /> 6. THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING FEATURES AND CONDITIONS(DIMENSIONS, ELEVATIONS, <br /> ETC.) UPON WHICH THESE DRAWINGS RELY. <br /> 7. OMISSIONS OR DISCREPANCIES BETWEEN THE VARIOUS ELEMENTS OF THE CONTRACT DOCUMENTS SHALL BE <br /> BROUGHT TO THE ATTENTION OF THE ENGINEER BEFORE PROCEEDING WITH THE WORK. <br /> 8. DO NOT SCALE DRAWINGS. <br /> 9. DURING THE CONSTRUCTION PERIOD,THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF PERSONNEL <br /> AND PROPERTY ON AND AROUND THE JOBSITE. THE CONTRACTOR SHALL PROVIDE ADEQUATE SHORING, <br /> BRACING,GUYS, E-C. IN ACCORDANCE WITH ALL NATIONAL,STATE,AND LOCAL SAFETY ORDINANCES. <br /> 10. THE DRAWINGS REPRESENTTHE FINISHED STRUCTURE. THE METHODS, PROCEDURES,AND SEQUENCE OF <br /> CONSTRUCTION ARE THE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR SHALL TAKE ALL NECESSARY <br /> PRECAUTIONS TO MAINTAIN AND ENSURE THE INTEGRITY OF THE STRUCTURE AT ALL STAGES OF CONSTRUCTION. <br /> 11. MAINTAIN CLEANLINESS DURING THE COURSE OF CONSTRUCTION IN ALL PARTS OF THE PREMISES, <br /> 12. THESE CONSTRUCTION DOCUMENTS ARE LIMITED TO THE AREAS OF WORK SHOWN. STRUCTURAL CHECKS FOR <br /> GRAVITY AND LATERAL LOADING HAVE NOT BEEN PERFORMED ON OTHER AREAS OF THE STRUCTURE. <br /> 13. CASE FORENSICS SCOPE OF SERVICES ARE LIMITED TO THE STRUCTURAL ASPECTS OF THE WORK SHOWN. <br /> ARCHITECTURAL BJILDING ENVELOPE, MECHANICAL, ELECTRICAL, ENERGY,VENTILATION, ETC. DETAILS ARE NOT <br /> INCLUDED IN THESE DOCUMENTS. <br /> 14. SMOKE REMEDIATION BY OTHERS. <br /> STRUCTURAL DESIGN CRITERIA <br /> 1. BUILDING CODE: 2012 INTERNATIONAL RESIDENTIAL CODE <br /> 2. DEAD LOADS: SELF WEIGHT OF STRUCTURE <br /> 3. LIVE LOADS: 25 PSF SNOW <br /> 40 PSF LIVE <br /> 4. WIND DESIGN DATA: RISK CATEGORY: II <br /> WIND EXPOSURE CATEGORY: C <br /> BASIC WIND SPEED:V=110 MPH,3 SECOND GUST. <br /> 5. SEISMIC DESIGN DATA: SOIL CLASS=D(ASSUMED) <br /> SDs=0.860,SDI=0.493 <br /> FRAMING LUMBER <br /> 1. FRAMING LUMBER GRADES:WWPA GRADING RULES-05. STRESS VALUES SHOWN ARE BASE MEMBER VALUES: <br /> A. ALL FRAMING MEMBERS TO BE HEM FIR No.2,S.DRY, Fb=850. <br /> B. ALL FASTENERS AT PRESSURE TREATED LUMBER SHALL BE HOT-DIPPED GALVANIZED. <br /> 2. STRUCTURAL SHEATHING: <br /> A. ALL PANES TO BE PLYWOOD OF MINIMUM 5 PLY CONSTRUCTION. EACH PANEL SHALL BEAR THE <br /> QUALITY--RADEMARK STAMP OF THE"AMERICAN PLYWOOD ASSOCIATION". <br /> B. THICKNESS TO MATCH EXISTING. %" MINIMUM AT WALLS AND%"MINIMUM AT ROOF. <br />