GENERAL NOTES: STEEL INSPECTION <br /> 1. CONTRACTOR SHALL COORDINATE WITH PORT STAFF AND PORT 1. STEEL SHAPES SHALL CONFORM TO ASTM A992, UNLESS NOTED OTHERWISE. 1. THE FOLLOWING ITEMS SHALL BE CONTINUOUSLY INSPECTED BY AN <br /> TENANT TO MINIMIZE DISRUPTION OF TENANT OPERATIONS DURING INDEPENDENT TESTING AGENT HIRED BY THE CONTRACTOR WHO IS <br /> CONSTRUCTION. 2. CHANNELS, ANGLES AND MISCELLANEOUS PLATES SHALL CONFORM CERTIFIED TO PERFORM THE FOLLOWING INSPECTIONS: <br /> TO ASTM A36 UNLESS NOTED OTHERWISE ON THE DRAWINGS. CCADHESIVE ANCHOR PLACEMENT <br /> 2, THESE NOTES CONTAIN GENERAL INFORMATION AND ARE TO BE 3. STEEL PLATE NOTED AS GRADE 50 SHALL CONFORM TO ASTM A572, GRADE 50. <br /> USED IN COMBINATION WITH SPECIFICATIONS AND OTHER - EXPANSION ANCHOR PLACEMENT <br /> DOCUMENTS. ALL CONFLICTS SHALL BE BROUGHT TO THE 4. ALL BOLTS AND NUTS SHALL CONFORM TO ASTM A307, UNLESS - FIELD PERFORMED FILLET WELDS > 5/16" <br /> ATTENTION OF THE ENGINEER BEFORE BEGINNING AFFECTED WORK. SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS. - FIELD PERFORMED PARTIAL OR COMPLETE PENETRATION WELDS <br /> - SHOP PERFORMED WELDS FOR WORK BY A FABRICATOR WHO IS <br /> 3. ALL DIMENSIONS AND DETAILS SHALL BE VERIFIED BY THE 5. ALL THREADED ANCHOR RODS AND NUTS SHALL CONFORM TO ASTM F1554, NOT AN IBC APPROVED FABRICATOR, UNLESS NOTED OTHERWISE IN <br /> CONTRACTOR PRIOR TO FABRICATION AND CONSTRUCTION. GRADE 105, UNO. THE SPECIFICATIONS. <br /> 4. ALL SHOP DRAWINGS FOR PILING, AND MISCELLANEOUS STEEL, 6. HEADED ANCHOR STUDS SHALL CONFORM TO ASTM A108 GRADES C1010 <br /> SHALL BE SUBMITTED TO AND REVIEWED BY THE ENGINEER PRIOR THROUGH C1020. 2. THE FOLLOWING ITEMS SHALL BE PERIODICALLY INSPECTED BY AN <br /> TO FABRICATION. 7. ALL MISCELLANEOUS STEEL, EXCEPT AS NOTED IN THE SPECIFICATION INDEPENDENT TESTING AGENT HIRED BY THE CONTRACTOR WHO IS <br /> CERTIFIED TO PERFORM THE FOLLOWING INSPECTIONS: <br /> 5. EXISTING CONDITIONS SHALL BE INSPECTED BY CONTRACTOR PRIOR AND/OR DRAWINGS, SHALL BE HOT DIPPED GALVANIZED. ALL OTHER - FIELD PERFORMED FILLET WELDS < 5/16" <br /> TO START OF WORK. THE ENGINEER SHALL BE NOTIFIED OF ANY EXPOSED METAL SHALL BE PAINTED. GALVANIZE ITEMS AFTER FABRICATION - REINFORCING STEEL PLACEMENT <br /> DISCREPANCIES BETWEEN THE PLANS AND THE ACTUAL CONDITIONS. AS FAR AS PRACTICAL. GALVANIZING DAMAGED ACCIDENTALLY OR DUE TO - CONCRETE TESTING <br /> 6. ALL EXISTING STRUCTURE AND UTILITIES OUTSIDE OF THE LIMITS FIELD WELDING SHALL BE RESTORED WITH FIELD-APPLIED GALVANIZING <br /> SHOWN ON SHEET SHALL REMAIN AS-IS. COMPOUND (SEE SPECIFICATIONS). 3. CONTINUOUS INSPECTION MEANS THAT THE INSPECTOR IS ON THE <br /> SITE AT ALL TIMES OBSERVING THE WORK REQUIRING INSPECTION. <br /> FENDER PILING NOTE FOR ADHESIVE ANCHOR PLACEMENT, THE INSPECTOR IS NOT <br /> EXCAVATION, SHORING AND DEWATERING REQUIRED TO BE ON SITE DURING DRILLING OPERATIONS, BUT IS <br /> 1. CONTRACTOR IS RESPONSIBLE FOR CONSTRUCTION LOADS BY 1. EXISTING CONDITIONS: CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AND REQUIRED TO BE ON SITE PRIOR TO EPDXY AND BOLT INSTALLATION <br /> PROVIDING ADEQUATE SHORING, BRACING, AND GUYING S ALL CONFORM, TO THEIR SATISFACTION, THE STABILITY OF THE EXISTING FENDER TO VERIFY BOLT HOLE DEPTH AND PREPARATION. <br /> COMPONENTS AS REQUIRED FOR SAFETY AND STRUCTURAL SYSTEMS PRIOR TO REMOVING AND REPLACING EXISTING FENDER PILES. <br /> INTEGRITY THROUGHOUT CONSTRUCTION IN ACCORDANCE WITH 4. PERIODIC INSPECTION MEANS THAT THE INSPECTOR IS ON SITE AT <br /> 2. PILES: FENDER PILES SHALL BE STEEL PIPE PILES CONFORMING TO ASTM TIME INTERVALS NECESSARY TO CONFIRM THAT ALL WORK REQUIRED <br /> SOUND PRACTICE AND ALL FEDERAL, STATE, AND LOCAL <br /> REQUIREMENTS. A252-98 GRADE 2, UNCOATED. INSPECTION IS IN COMPLIANCE. <br /> 3. PILE DIMENSIONS: 12i"e O.D. x i" WALL THICKNESS, LENGTH AS REQUIRED. 5. SEE SPECIFICATIONS FOR ADDITIONAL INSPECTION REQUIREMENTS. <br /> REFERENCED DOCUMENTS <br /> 4. INSTALLATION: PILES SHALL BE VIBRATORY DRIVEN TO 10'-0" MINIMUM <br /> 1. 2012 IBC, INTERNATIONAL BUILDING CODE (IBC) PENETRATION. CUT-OFF NEW FENDER PILES AT ELEVATION TO MATCH ABBREVIATIONS <br /> 2. ANSI/ASCE 7 "MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES" EXISTING ADJACENT PILES. FIELD WELD STEEL PLATE TO SEAL TOP OF PILE. <br /> AMERICAN SOCIETY OF CIVIL ENGINEERS. GRIND WELD SMOOTH. BTWN BETWEEN <br /> 3. BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE ACI 318-11 AMERICAN 5. HARDWARE: REUSE EXISTING HARDWARE IN GOOD CONDITION. PROVIDE NEW CL CENTERLINE <br /> CONCRETE INSTITUTE. HARDWARE WHERE SHOWN ON THE DRAWINGS. ALL NEW HARDWARE HOT-DIP CONIC CONCRETE <br /> GALVANIZED A36 STEEL (UNO). TOUCH-UP DAMAGED GALVANIZING WITH DET. DETAIL <br /> 4. AISC MANUAL OF STEEL CONSTRUCTION, 14TH EDITION, 2010 FIELD APPLIED COLD GALVANIZING COMPOUND. ° DIAMETER <br /> EL., ELEV ELEVATION <br /> EX, EXST EXISTING <br /> GALV GALVANIZED <br /> DESIGN LOADS EPDXY ANCHORS HDG HOT-DIP GALVANIZED <br /> 1. ANCHORS SHALL BE ATTACHED TO CONCRETE USING HILTI HIT-HY 200-A LG LONG <br /> 1. DESIGN OF WALER AND CONNECTION BASED ON EARTH PRESSURE ADHESIVE ANCHOR SYSTEM, W HILTI HIT-Z RODS OR APPROVED OC ON CENTER <br /> LOADS PROVIDED IN THE GEOTECHNICAL REPORT BY LANDAU & / PCF POUNDS PER CUBIC FOOT <br /> ASSOCIATES, DATED AUGUST 19TH, 2008. ALTERNATIVE. RE PLATE <br /> REF REFERENCE <br /> 2. EMBEDMENT LENGTHS AND BOLT SIZES AND TYPES SHALL BE AS SHOWN SECT. SECTION <br /> ON PLANS. TBD TO BE DETERMINED BY PORT <br /> TYP TYPICAL <br /> 3. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION. UNO UNLESS NOTED OTHERWISE <br /> WF WIDE FLANGE <br /> NONSHRINK GROUT <br /> 1. DAYTON-SUPERIOR "SURE GRIP" OR APPROVED EQUAL. LEGEND: <br /> WELDING DETAIL # <br /> 1. ALL WELDING SHALL BE PERFORMED BY WELDERS QUALIFIED FOR THE �/ <br /> WELDING AND POSITION SHOWN IN ACCORDANCE WITH AWS AND HAVING SHEET # <br /> CURRENT CERTIFICATION FROM WABO. WHERE DETAIL �Y Z <br /> 2. ALL WELDS SHALL BE PERFORMED WITH PROCEDURES PREQUALIFIED OR IS CALLED FROM SHEET # <br /> QUALIFIED IN ACCORDANCE WITH AWS D1.1 AND D1.4. <br /> WHERE DETAIL <br /> 3. THE WELDS SHOWN ARE FOR THE FINAL CONNECTIONS. FIELD WELD OCCURS <br /> SYMBOLS ARE SHOWN WHERE FIELD WELDS ARE REQUIRED BY THE <br /> STRUCTURAL DESIGN. <br /> 4. WELDING ELECTRODES SHALL BE 70 KSI STRENGTH AND SHALL BE <br /> "LOW-HYDORGEN" ELECTRODES. <br /> NOTE: FULL SIZE IS 22" x 34" <br /> PROJECT ENGINEER: SCALE: PORT OF EVERETT DWG. N0. <br /> R. RILEY AS SHOWN S1.0 <br /> DESIGNED BY: DATE: <br /> O ✓ F <br /> Port o J. HINGTGEN 7/27/2015 <br /> /27/2015 <br /> DUNLAP BULKHEAD QIP NO. <br /> a 1-0-015-01 W�/ <br /> �j��j 1Tff DRAWN BY: CHECKED BY: RENOVATION YI <br /> EVER 1 i w G. CAREY R. RILEY PROJECT <br /> 16015th Avenue,Suite 1300 <br /> > o w NO. MT-HT-2015-06 <br /> P.O. BOX 538 �DATEb <br /> ISSUED FOR BID. s� L� o� APPROVE STRUCTURAL NOTES T E SC <br /> EVERETT, WA 98205 Seattle,Washington 98101 ONAL k� <br /> (425) 259-3164 (206)382-0600 Fax(206)382-0500 SHEET N0. OF <br /> REVISION N0. DATE BY REVISION .w-^^a"4. _ 23 <br />
The URL can be used to link to this page
Your browser does not support the video tag.