My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2702 FEDERAL AVE 2017-05-23
>
Address Records
>
FEDERAL AVE
>
2702
>
2702 FEDERAL AVE 2017-05-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/23/2017 2:23:25 PM
Creation date
5/23/2017 2:23:18 PM
Metadata
Fields
Template:
Address Document
Street Name
FEDERAL AVE
Street Number
2702
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CONDUIT AND RACEWAY POWER DRAWING CONVENTIONS SHEET INDEX <br /> HEAVY SOLID LINES AND JUNCTION BOX A TITLE DETAIL/SECTION <br /> ETION TITLE E1.0 ELECTRICAL ABBREVIATIONS, SYMBOLS AND NOTES <br /> DARK TEXT INDICATE NEWE1.1 NOT USED <br /> CONDUIT, MATERIAL AND PANEL Et SCALE:1/4'=I'-O' E1 E SHEET WHERE E1.2 ELECTRICAL PLAN <br /> EQUIPMENT THAT IS REFERENCED <br /> EXPOSED. Q HANDHOLE AS NOTED a a A = DETAIL/SECTION <br /> E2 E2 NUMBER <br /> LIGHT SOLID LINES AND E2 = SHEET WHERE SHOWN <br /> LIGHT TEXT INDICATE <br /> EXISTING CONDUIT, GENERAL NOTES <br /> MATERIAL AND EQUIPMENT <br /> THAT IS EXPOSED 1. MEET ALL REQUIREMENTS OF THE NEC AND AHJ <br /> FOR INSTALLATION AND CONSTRUCTION. <br /> HEAVY DASHED LINES O3 NOTE 2. ALL EXTERIOR EQUIPMENT SHALL BE <br /> AND DARK TEXT INDICATE <br /> WEATHERPROOF. <br /> ——————— NEW CONDUIT, MATERIAL <br /> AND EQUIPMENT HIDDEN Qj REVISION REFERENCE <br /> FROM VIEW. 3. THE EXISTING ELECTRICAL SERVICES TO THE <br /> BULKHEAD RECEPTACLES SHALL REMAIN IN SERVICE <br /> N AT ALL TIMES UNLESS AN ELECTRICAL OUTAGE IS <br /> LIGHT DASHED LINES AND SCHEDULED PER SPECIFICATION 16010 GENERAL <br /> LIGHT TEXT INDICATE ELECTRICAL PROVISIONS, PARAGRAPH 1.06E. <br /> EXISTING CONDUIT, <br /> MATERIAL AND EQUIPMENT <br /> HIDDEN FROM VIEW. <br /> ,r CONTINUOUS HATCHING NORTH ARROW <br /> INDICATES ITEMS TO BE <br /> REMOVED <br /> —� CONDUIT DOWN <br /> CONDUIT UP <br /> CONDUIT STUBBED AND <br /> CAPPED AS SHOWN <br /> CONDUIT CONTINUED <br /> CONDUIT CAPPED <br /> ABBREVIATIONS <br /> A AMMETER, AMPERE ELEV ELEVATION, ELEVATOR PH PHASE <br /> AFG ABOVE FINISHED GRADE EMT ELECTRICAL METALLIC TUBING PNL PANEL <br /> AHJ AUTHORITY HAVING EXIST EXISTING <br /> JURISDICTION RM ROOM <br /> G,GND GROUND <br /> BLDG BUILDING GALV GALVANIZED SCHED SCHEDULE <br /> GRC,GRS GALVANIZED RIGID STEEL SHT SHEET <br /> C CONDUIT SNO SNOHOMISH COUNTY <br /> CB CIRCUIT BREAKER HH HANDHOLE SYM SYMMETRICAL <br /> CKT CIRCUIT <br /> CLR CLEAR JB,J—BOX JUNCTION BOX TYP TYPICAL <br /> C.O. CONDUIT ONLY <br /> CONC CONCRETE MH MANHOLE UG UNDERGROUND <br /> CONT CONTINUED MIN MINIMUM LINO UNLESS NOTED OTHERWISE <br /> MTG MOUNTING <br /> L) DEMO DEMOLITION V VOLTMETER, VOLT <br /> DISC DISCONNECT N NEUTRAL, NEW <br /> E DN DOWN NEUT NEUTRAL W/ WITH <br /> a DWG DRAWING NIC NOT IN CONTRACT W/O WITHOUT <br /> � E EMPTY, EXISTING 0 PHASE, DIAMETER WP WEATHERPROOF <br /> ELEC ELECTRICAL P PANEL, POLE <br /> N NOTE: FULL SIZE IS 22" x 34" <br /> r <br /> 0 PROJECT ENGINEER: SCALE: DWG, NO. <br /> w H. SMYTH AS SHOWN PORT OF EVERETT E1.0 <br /> rn �yN A.Sofa. DESIGNED BY: DATE: <br /> port o ELC N H. SMYTH DAM'7/27/2015 D U N LA P BULKHEAD C,P No. F <br /> 51, ASSOCIATES,INC. LL <br /> o DRAWN BY: CHECKED BY: RENOVATION 1-0-015-01 <br /> "2 ENGINEERS-CONSULTANTS - PROJECT <br /> (206)24&a22 wwwelcoRcom � 32 a y J. TAYLOR S. BARTKOSKE No. MT—HT-2015-06 <br /> I P.O. BOX 538 TS,700CNRISTENSENROAD,5TE330 QO 7/27/15 HAS ISSUED FOR BID. ,ONA> �Gti "PPR ELECTRICAL ABBREVIATIONS C <br /> EVERETT, WA 98206 SEATTLE WA9Bi8B - 2Ak <br /> (425) 259-3164 NO. DnTE BY RENSION NO. DATE BY REVISION T/2�J/IS SYMBOLS AND NOTES SHEET NO. 21 OF 23 i <br />
The URL can be used to link to this page
Your browser does not support the video tag.