Laserfiche WebLink
Three Nail Designs <br /> Rusi,lcmi.11 Draftino &- Dei-,n <br /> in li)(CVT <br /> August 29,2013 <br /> Re: Gillum,2105 Grand Ave. : BW 1307-003 <br /> Mr. Heilman, <br /> This is in response to your letter of 8/19. <br /> 1. A pony wall will be built on top of existing,rafter bearing,walls to support <br /> existing rafters. A detail has been added and referenced on page 9. <br /> 2. The headers at the front windows must be a minimum 2x6.The newporch <br /> beam muct be a 4x8. I have noted this on page 7,and have included the beam calcs. <br /> 3. Shearwall schedule is on the"S"pages following 10. <br /> 4. "S"pages have been included following page 10. <br /> 5. The basement was and will remain unfinished,this was an error due to a <br /> software upgrade referencing an option that we discarded.All work to be done has <br /> been clouded and noted as such. <br /> 6. Water proof deck detail has been added to page 8 and railing details on page <br /> 10 have been referenced on page 8. <br /> 7. All code references have been updated to 2012 IRC and WSEC. <br /> 8. Smoke alarms have been added to pages 6, 7,&8 and referenced to be <br /> installed per R314. <br /> 9. Carbon monoxide alarms have been added to pages 6,7,&8 and referenced <br /> to be installed per R315. <br /> 10. The post has been noted to make contact with solid concrete for proper <br /> installation of hold down. <br /> 11. Engineering calcs have been attached. <br /> 12. Wall legend has been added to page 8 and referenced on pages 6&7. <br /> 13. The basement was and is to remain unfinished as noted for#5 above. Since <br /> there was nothing being changed down there,I did not spend much time there,just <br /> enough to take a few measurements. Ray assured me that there exists a framed out <br /> wall at the interior basement foundation walls. <br /> Please let me know if there is anything else. <br /> Thanks. <br /> Jeff Harlan <br /> jeff@threenaildeisgns.com <br />