Laserfiche WebLink
PVB�sc 0V/ZK.s <br /> ADMINISTRATIVE ACTION <br /> DATE: June 16, 2003 <br /> LOCATION: Regional Special ]Events Center, 2000 Hewitt Avenue <br /> ACTION: Acceptance of brick veneer tie spacing along grid 5, K-L <br /> FINDINGS: <br /> • Ties in the affected area are supporting 33% more area of brick than the <br /> maximum area specified(2sq.ft./tie). <br /> • Additional ties were added above the non-complying location to compensate <br /> for the missing ties (if based on gross wall area). <br /> • The metal stud framing designer sites, no adverse affect on the stud design. <br /> • The screws that attach the ties to the studs in the non-complying location have a <br /> pullout factor of safety of approximately 3.3. <br /> • Specified spacing requirements are prescriptive. <br /> Tim Tyler <br /> Building Official <br /> DED=LER/AA REGIONAL SPECIAL EVENTS CENTER(2000 HEWITT AVE) <br /> CITY OF EVERETT• 3200 Cedar Street 9 Everett, WA 98201 • (425) 257-8800 • Fax (425) 257-8856 <br />