My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
510 HOME PL 2017-05-24
>
Address Records
>
HOME PL
>
510
>
510 HOME PL 2017-05-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/24/2017 3:37:34 PM
Creation date
5/24/2017 3:37:31 PM
Metadata
Fields
Template:
Address Document
Street Name
HOME PL
Street Number
510
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
11 V�" <br /> BEDROOM BEDROOM <br /> 2 PEC ROOMEllREC Poom 19 <br /> \ <br /> LINEN <br /> c;I -----------I a I <br /> ATHROOM ❑ <br /> CLOSET <br /> BATHROOM NOOK it <br /> 01— 0 a <br /> LAUNDRY ------- <br /> LAUNOPY 11 <br /> 1' LI 9 <br /> 6 1 <br /> - WET BAR u <br /> SHOP 13 T-J BONUS ROOM OFFICE - <br /> 14'-4"x 9'-5" 30 <br /> BUILT-IN SHELVES <br /> BASEMENT DEMOLITION PLAN BASEMENT CONSTRUCTION PLAN <br /> [fl CONSTRUCT WOOD FRAMED WALL PER SECTION 1/1 THIS PAGE (TYPICAL) <br /> RELOCATE TOILET CENTERED BETWEEN THE NEW PARTITION AND EXISTING WALL <br /> (1)REMOVE EXISTING WOOD FRAMED WALL. REPLACE EXISTING VANITY AND LAVATORY. <br /> Q REMOVE EXISTING CLOSET DOOR AND RETURNS INSTALL NEW 60" SHOWER STALL. VERIFY WIDTH WITH OWNER <br /> To BE FLUSH WITH EXISTING WALL <br /> Q REMOVE EXISTING SHOWER STALL. [51 INSTALL NEW LINEN CLOSET WITH 5 SHELVES EVENLY SPACED. <br /> REMOVE EXISTING 2668 DOOR AND WALLS ON EACH SIDE [61 INSTALL NEW 2'-4" POCKET DOOR. <br /> TO BE FLUSH WITH HALL. <br /> (3 REMOVE EXISTING BUILT-IN STORAGE SHELVES. [7] INSTALL NEW 5'-0" BI-FOLD DOORS. <br /> (3) REMOVE EXISTING BUILT-IN STORAGE SHELVES. INSTALL NEW SHELF AND POLE. VERIFY HEIGHT WITH OWNER. <br /> Q) REMOVE EXISTING 2468 DOOR. INSTALL UPPER AND LOWER CABINETS PER OWNERS SPECIFICATIONS. <br /> REMOVE EXISTING TOILET, VANITY CABINET AND SINK. 10 INSTALL UPPER AND LOWER CABINETS FOR WET RAP. WITH SINK,SIZE SPECIFIED BY OWNER. <br /> it INSTALL NEW UPPER AND LOWER CABINETS ON EAST AND WEST WALLS OF UTILITY ROOM. Lij <br /> 12 INSTALL NEW UTILITY SINK IN NEW CABINET USE EXISTING PLUMBING. <br /> r 7irl'6 2 rl 01-w bi:'l Al 161, O�C. z <br /> 13 PROVIDE SEISMIC STRAPS FOR EXISTING WATER HEATER AND PRV TO EXTERIOR. <br /> LL- <br /> D <br /> VERIFY CLEARANCES REQUIRED FOR NEW WALL ADJACENT TO THE EXISTING F/A FURNACE. <br /> -i <br /> Lu <br /> INSTALL NEW 5'-0" BI-FOLD DOORS WITH LOUVERS FOR COMBUSTION AIR FOR F/A FURNACE. pco <br /> flkEP-r,'<Nf,Ar 10' 01' 04, N ICA <br /> 2 <br /> INSTALL NEW 2 -B" ' <br /> X 6 -8" FOAM CORE DOOR. STYLE SPECIFIED BY OWNER.�4 P. 111U).� A- IE '%. . ' LLJ <br /> 0-15 r-� PICA" Iv5Un ^V 1 (.W' 0\4 <br /> 17 INSTALL NEW 2'-B" X 6'-8" FOAM CORE DOOR. STYLE SPECIFIED BY OWNER. <br /> A-A-[- IK[Nl*[ LAY LD <br /> LLJ <br /> IB FUR OUT EXISTING 2X4 WALL TO 5-1/2" FOR R-21 INSULATION. THIS WALL ONLY. C) <br /> d?, 511V5 Af b" O.C. <br /> Wl-I r-1CAI'INLtkl0N 19 INSTALL CONTINUOUS LAYER OF R-5 RIGID INSULATION DIRECTLY ON CONCRETE WALLS. FRAME 2X4 <br /> H.F. #2 STUDS AT 16" O.C. PER DETAIL 1,INSULATE FRAMED WALL WITH MINIMUM R-13 INSULATION. <br /> PROVIDE SMOKE ALARMS PER SECTION R314 IRC AND CARBON MONOXIDE ALARMS PER R315 IRC <br /> r VERIFY MINIMUM 50 CFM EXHAUST FAN VENTED TO THE EXTERIOR. <br /> TYPICAL BASEMENT SECTION <br />
The URL can be used to link to this page
Your browser does not support the video tag.