STRUCTURAL STEEL NOTES: WEATHERPROOFING NOTES: ELECTRICAL NOTES: <br /> 1. ALL STEELWORK SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE AISC MANUAL OF STEEL STANDARD CONSTRUCTION SPECIFICATIONS FOR WIRELESS SITES 1. ELECTRICAL CONTRACTOR SHALL SUPPLY AND INSTALL ANY/ALL ELECTRICAL WORK INDICATED.ANY/ALL CONSTRUCTION SHALL BE IN <br /> CONSTRUCTION.STEEL SECTIONS SHALL BE IN ACCORDANCE WITH ASTM AS INDICATED BELOW: ACCORDANCE W/DRAWINGS AND ANY/ALL APPLICABLE SPECIFICATONS.IF ANY PROBLEMS ARE ENCOUNTERED BY COMPLYING WITH THESE Sprint)� <br /> 3.6 WEATHERPROOFING CONNECTORS AND GROUND KITS: REQUIREMENTS,CONTRACTOR SHALL NOTIFY'CONSTRUCTION MANAGER'AS SOON AS POSSIBLE,AFTER THE DISCOVERY OF THE PROBLEMS, <br /> WSHAPES:ASTM A992.50 KSI A. ALL CONNECTORS AND GROUND KITS SHALL BE WEATHERPROOFED USING BUTYL RUBBER WEATHERPROOFING AND TAPE.THIS AND SHALL NOT PROCEED WITH THAT PORTION OF WORK,UNTIL THE'CONSTRUCTION MANAGER'HAS DIRECTED THE CORRECTIVE ACTIONS TO <br /> ANGLES,BARS CHANNELS:ASTM A36,36 KSI INSTALLATION MUST BE DONE IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATION OR AS SHOWN ON THE BE TAKEN. <br /> HSS SECTIONS:ASTM 500,46 KSI CONSTRUCTION DRAWINGS(WHICHEVER IS GREATER).IF NO DIRECTION IS PROVIDED,WEATHERPROOFING MUST BE DONE PER <br /> PIPE SECTIONS:ASTM A53-E,35 KSI THE FOLLOWING INSTRUCTIONS. 2. ELECTRICAL CONTRACTOR SHALL VISIT THE JOB SITE AND FAMILIARIZE HIMSELF WITH ANY/ALL CONDITIONS AFFECTING ELECTRICAL AND <br /> COMMUNICATION INSTALLATION AND MAKE PROVISIONS AS TO THE COST THEREOF.ALL EXISTING CONDITIONS OF ELECTRICAL EQUIP.,LIGHT PROJECT INFORMATION: <br /> 2. ALL EXTERIOR EXPOSED STEEL AND HARDWARE SHALL BE HOT DIPPED GALVANIZED. 1. THE COAXIAL CABLE CONNECTION OR GROUND KIT CAN BE ENCOMPASSED INTO COLD SHRINK AND COMPLETELY WRAPPED FIXTURES,ETC.,THAT ARE PART OF THE FINAL SYSTEM,SHALL BE VERIFIED BY THE CONTRACTOR,PRIOR TO THE SUBMITTAL OF HIS BID. <br /> WITH 2INCH WIDE ELECTRICAL TAPE OVERLAPPING EACH ROW BY APPROXIMATELY WAND EXTENDING PAST THE CONNECTION FAILURE TO COMPLY WITH THIS PARAGRAPH WILL IN NO WAY RELIEVE CONTRACTOR OF PERFORMING ALL WORK NECESSARY FOR A <br /> 3. ALL WELDING SHALL BE PERFORMED USING E70XX WHERE FILLET WELD SIZES ARE NOT SHOWN,PROVIDE THE MINIMUM SIZE PER TABLE J2.4 IN THE AISODES AND WELDING SHALL CONFORM TO SC. BY TWO INCHES AS DISCUSSED BELOW;OR COMPLETE AND WORKING SYSTEM. BROADWAY <br /> "MANUAL OF STEEL CONSTRUCTION'.PAINTED SURFACES SHALL BE TOUCHED UP. 2.THE <br /> COAXIAL <br /> CABLE <br /> CONNETAPE C IOISC R GROUND <br /> BELKIT <br /> ORCAN <br /> BE WRAPPED WITH LAYERS OF ELECTRICAUBUTYL 3. LALL WORK SHALL BE OCAL OWER 8 TELEPHONE PERFORMED <br /> IN ACCORDANCE <br /> ES NG JUV61TH THE LATEST RIST CION AND EDITION <br /> SHALL NOOF THE <br /> EDNEC <br /> AND NOT ALL CODES BE LIMITED AND LOCAL ORDINANCES OF THE S E63XC209 <br /> RUBBER4. NONSTURCUTRAL CONNECTIONS FOR STEEL GRATING MAY USE 5B"0 ASTM A 307 BOLTS UNLESS NOTED <br /> OTHERWISE.. 3.THE COAXIAL CABLE CONNECTION OR GROUND KIT CAN BE WRAPPED WITH TWO LAYERS OF 1.5 INCH WIDE A UL-UNDERWRITERS LABORATORIES <br /> SELF-AMALGAMATING TAPE COVERED WITH TWO LAYERS OF ELECTRICAL TAPE AS DISCUSSED BELOW. B.NEC-NATIONAL ELECTRICAL CODE 2517 HOWARD AVE <br /> 5. FIELD MODIFICATIONS ARE TO BE COATED WITH ZINC ENRICHED PAINT. C.NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOC, EVERETT,WA 98203 <br /> B. COLD SHRINK INSTALLATION PROCEDURE: D.OSHA-OCCUPATIONAL SAFETY AND HEALTH ACT <br /> E IBC-INTERNATIONAL BUILDING CODE <br /> 1. REQUIRED MATERIALCOLD SHRINK TUBE,SPACERS AS NEEDED,BLACK ELECTRICAL TAPE-2 INCHES WIDE. F.NFPA-NATIONAL FIRE CODES ISSUED FOR: <br /> STRUCTURAL CONCRETE NOTES: 4. DO NOT SCALE ELECTRICAL DRAWINGS,REFER TO SITE PLANS AND ELEVATIONS FOR EXACT LOCATIONS OF ALL EQUIPMENT,AND CONFIRM <br /> 1. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE ACI 301-05,ACI 318-05 AND THE SPECIFICATION 2.REQUIRED TOOLS:KNIFE AND TAPE MEASURE WITH'CONSTRUCTION MANAGEF ANY SIZES AND AND LOCATIONS WHEN NEEDED. BUILDING PERMIT <br /> FOR CAST-IN-PLACE CONCRETE. STEP 1:THOROUGHLY CLEAN AND DRY THE SURFACE OF COAXIAL CABLE AND CONNECTOR TO REMOVE ALL GREASE AND DIRT. 5. EXISTING SERVICES:CONTRACTOR SHALL NOT INTERRUPT EXISTING SERVICES WITHOUT WRITTEN PERMISSION OF THE OWNER. REVISION HISTORY: <br /> MARK THE MAIN FEED(LARGER DIAMETER)COAXIAL CABLE AT LEAST TWO INCHES ABOVE THE CONNECTION AS THE SPECIFIED <br /> 2. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH fe=3,000 PSI AT 28 DAYS UNLESS NOTED START DIMENSION FOR THE COLD SHRINK. 6. CONTRACTOR SHALL PAY FOR ANY/ALL PERMITS,FEES,INSPECTIONS AND TESTING.CONTRACTOR IS TO OBTAIN PERMITS AND APPROVED NO. DATE: DESCRIPTION: CHK. <br /> OTHERWISE. SUBMITTALS PRIOR TO THE WORK BEGINNING OR ORDERING EQUIPMENT. BY: <br /> STEP 2:SLIDE THE COLD SHRINK TUBE OVER THE PRE-CONNECTORIZED END OF THE LARGER DIAMETER COAXIAL CABLE PRIOR <br /> 3. REINFORCING STEEL SHALL CONFORM TO ASTM A 615,GRADE 60,DEFORMED UNLESS NOTED OTHERWISE. TO MATING CONNECTOR INTERFACES.MAKE THE CONNECTION. 7, THE TERM'PROVIDE"USED IN CONSTRUCTION DOCUMENTS AND SPECIFICATIONS,INDICATES THAT THE CONTRACTOR SHALL FURNISH AND <br /> WELDED WIRE FABRIC SHALL CONFORM TO ASTM A 185 WELDED STEEL WIRE FABRIC UNLESS NOTED STEP 3:REMOVE WAX PAPER FROM A SPACER HALF AND PRESS ONTO COAXIAL CABLE DIRECTLY BEHIND THE CONNECTOR. INSTALL <br /> OTHERWISE.SPUCES CLASS BAND ALL HOOKS SHALL BE STANDARD UNLESS NOTED OTHERWISE. REMOVE THE WAX PAPER FROM THE OTHER SPACER HALF AND ALIGN THE TWO SPACER HALVES WITH ADHESIVE PORTIONS <br /> FACING EACH OTHER.PRESS THE SPACER HALVES TOGETHER.THE SPACER WILL BE PLACED NEXT TO THE CONNECTOR ON 8. CONTRACTOR SHALL CONFIRM WITH LOCAL UTILITY COMPANY ANY/ALL REQUIREMENTS SUCH AS THE:LUG SIZE RESTRICTIONS,CONDUIT <br /> 4. THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR REINFORCING STEEL UNLESS SHOWN THE SMALLER DIAMETER COAXIAL CABLE SIDE. ENTRY,SIZE OF TRANSFORMERS,SCHEDULED DOWNTIME FOR THE OWNERS'CONFIRMATION,ETC.ANY/ALL CONFLICTS SHALL BE BROUGHT TO <br /> OTHERWISE ON DRAWINGS: THE ATTENTION OF THE CONSTRUCTION MANAGER,PRIOR TO BEGINNING ANY WORK <br /> STEP 4:SLIDE THE COLD SHRINK TUBE OVER THE CONNECTION TO THE SPECIFIED START DIMENSION MARK.HOLD THE COLD <br /> CONCRETE CAST AGAINST EARTH...............3 IN. SHRINK TUBE AND COAXIAL CABLE IN ONE HAND SO THAT THE EDGE OF COLD SHRINK TUBE IS IN LINE WITH THE MARK. 9. MINIMUM WIRE SIZE SHALL BE#12 AWG,NOT INCLUDING CONTROL WIRING,UNLESS NOTED OTHERWISE.ALL CONDUCTORS SHALL BE COPPER <br /> STEP 5:WITH YOUR FREE HAND,BEGIN REMOVING COLD SHRINK TUBE CORE.THE CORE WILL BE REMOVED BY UNWINDING IN A WITH THWN INSULATION. <br /> CONCRETE EXPOSED TO EARTH OR WEATHER: COUNTERCLOCKWISE DIRECTION WHILE LIGHTLY PULUNG THE ATTACHED CORD AWAY FROM THE TUBE. <br /> #6 AND LARGER..............21N. 10. OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS,CAST ALLOY WITH THREADED HUBS IN WET/DAMP LOCATIONS AND SPECIAL <br /> #5 AND SMALLER 8 WWF...............I 121N. STEP 6:USE BOTH HANDS TO CONTINUE THE UNWINDING PROCESS AS THE COLD SHRINK TUBE BEGINS TO COLLAPSE INTO ENCLOSURES FOR OTHER CLASSIFIED AREAS. <br /> POSITION.CONTINUE THE UNWINDING PROCESS UNTIL THE CORE IS COMPLETELY REMOVED AND THE COLD SHRINK TUBE IS <br /> CONCRETE NOT EXPOSED TO EARTH OR WEATHER OR NOT CAST AGAINST THE GROUND: INSTALLED. 11. IT IS NOT THE INTENT OF THESE PLANS TO SHOW EVERY MINOR DETAIL OF THE CONSTRUCTION.CONTRACTOR IS EXPECTED TO FURNISH AND <br /> SLAB AND WALL...............314 IN. INSTALL ALL ITEMS FOR A COMPLETE ELECTRICAL SYSTEM AND PROVIDE ALL REQUIREMENTS FOR THE EQUIPMENT TO BE PLACED IN PROPER <br /> BEAMS AND COLUMNS...............1 12STEP 7:EXCESS COLD SHRINK TUBE EXTENDING TWO INCHES BEYOND THE SPACER HALVES CAN BE REMOVED OR LEFT IN 1N. WORKING ORDER. Q <br /> PLACE.EXCESS COLD SHRINK TUBE CAN BE CAREFULLY CUT OFF WITH A KNIFE. 1272014 SHEET A�ADDED. B,fT <br /> 5. A 3/4"CHAMFER SHALL BE PROVIDED AT ALL EXPOSED EDGES OF CONCRETE U.N.O.IN ACCORDANCE WITH STEP 8:WRAP OVER THE COLD SHRINK TUBE WITH ONE LAYER OF BLACK ELECTRICAL TAPE 2INCH WIDTH OVERLAPPING EACH 12. ELECTRICAL SYSTEM SHALL BE AS COMPLETELY AND EFFECTIVELY GROUNDED,AS REQUIRED BY SPECIFICATION,SET FORTH BY SPRINT. 2 <br /> ACI 301 SECTION 42.4 ROW BY 12 INCH.THIS TOP LAYER MUST BE WRAPPED USING A SHINGLED EFFECT.THE LAYER SHALL BE WRAPPED SO THAT <br /> 6. HOLES TO RECEIVE EXPANSIONNVEDGE ANCHORS SHALL BE 1/8'LARGER IN DIAMETER THAN THE ANCHOR <br /> THE ENDS ARE IN THE UPWARD DIRECTION CREATING A SHINGLED EFFECT WITH THE TAPE SO WATER WILL BE REPELLED AND 13. ALL WORK SHALL BE PERFORMED BY LICENSED ELECTRICAL CONTRACTOR IN A FIRST CLASS,WORKMANLIKE MANNER.THE COMPLETED Q 1/132014 ISSUED DESIGN REVIEW BJT <br /> NOT ALLOWED TO COLLECT AND POOL THIS TOP LAYER OF ELECTRICAL TAPE MUST EXTEND TWO INCHES(THE TAPE WIDTH) SYSTEM SHALL BE FULL OPERATIVE AND SUBJECT TO REGULATORY INSPECTION AND APPROVAL BY CONSTRUCTION MANAGER. <br /> BOLT,DOWEL OR ROD AND SHALL CONFORM TO MANUFACTURER'S RECOMMENDATION FOR EMBEDMENT PAST THE COLD SHRINK TUBE ONTO THE UNDERLYING CABLE.TAPE SHALL BE WRAPPED SO THAT NO VOIDS OR AIR PACKETS <br /> DEPTH OR AS SHOWN ON THE DRAWINGS.LOCATE AND AVOID CUTTING EXISTING REBAR WHEN DRILLING ARE PRESENT.TAPE SHALL BE CUT WITH A SHARP KNIFE. 14. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION. PLANS PREPARED BY: <br /> HOLES IN ELEVATED CONCRETE SLABS. <br /> C. BUTYL RUBBER TAPE INSTALLATION PROCEDURE: 15. CONTRACTOR SHALL GUARANTEE ANY/ALL MATERIALS AND WORK FREE FROM DEFECTS OR A PERIOD OF NOT LESS THAN ONE YEAR FROM <br /> 7. USE AND INSTALLATION OF CONCRETE EXPANSION/WEDGE ANCHOR.SHALL BE PER ICBO&MANUFACTURER'S DATE OF ACCEPTANCE. B. J. THOMAS, P.E. <br /> WRITTEN RECOMMENDED PROCEDURES. 1. REQUIRED MATERIAL BLACK ELECTRICAL TAPE-2 INCH WIDE AND BUTYL RUBBER TAPE 2 TO 3 INCHES WIDE. <br /> 16. THE CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ANY ADDITIONAL CHARGE AND SHALL INCLUDE THE REPLACEMENT OF 7607 80TH AVE NE <br /> 2.REQUIRED TOOLS:KNIFE OR SCISSORS. THE REPAIR OF ANY OTHER PHASE OF THE INSTALLATION,WHICH MAY HAVE BEEN DAMAGED THEREIN. <br /> MARYSVILLE, WA 98270 <br /> STEP1:THOROUGHLY CLEAN AND DRY THE SURFACE OF COAXIAL CABLE AND CONNECTOR TO REMOVE ALL GREASE AND DIRT. 17. ADEQUATE AND REQUIRED LIABILITY INSURANCE SHALL BE PROVIDED FOR PROTECTION AGAINST PUBLIC LOSS AND ANY/ALL PROPERTY <br /> CONCRETE MASONRY NOTES: WRAP CONNECTOR/GROUND KIT WITH TWO LAYERS OF BLACK ELECTRICAL TAPE-2 INCH WIDTH OVERLAPPING EACH ROW BY DAMAGE FOR THE DURATION OF WORK. 206-851-1106 <br /> APPROXIMATELY 12 INCH.THESE LAYERS OF TAPE MUST BE WRAPPED TIGHT ENOUGH SO THAT NO VOIDS OR AIR PACKETS ARE 18. PROVIDE AND INSTALL CONDUIT,CONDUCTORS,PULL WIRES,BOXES,COVER PLATES AND DEVICES FOR ALL OUTLETS AS INDICATED, <br /> PRESENT AND MUST EXTEND ONE INCH PAST THE CONNECTORIGROUND KIT ON EACH SIDE.TWO ROWS SHALL BE APPLIED,ONE <br /> 1. CONCRETE MASONRY UNITS SHALL BE MEDIUM WEIGHT UNITS CONFORMING TO ASTM C90,GRADE N-1, IN EACH DIRECTION,WITH THE TOP ROW SHINGLED TO PROMOTE WATER RUNOFF. DRAWN BY: CHK.BY: <br /> (FM=1,500 PS).MEDIUM WEIGHT(115 PCF). 19. DITCHING AND BACK FILL:CONTRACTOR SHALL PROVIDE FOR ALL UNDERGROUND INSTALLED CONDUIT AND/OR CABLES INCLUDING <br /> STEP 2:WRAP CONNECTORIGROUND KIT WITH ONE LAYER OF BUTYL RUBBER TAPE(2 TO 3 INCHES WIDTH)OVER THE BLACK EXCAVATION AND BACKFILLING AND COMPACTION.REFER TO NOTES AND REQUIREMENTS,EXCAVATION,AND BACKFILLING. <br /> 2. MORTAR SHALL BE TYPE'S'(MINIMUM 1,800 PSI AT 28 DAYS). ELECTRICAL TAPE OVERLAPPING EACH ROW BY APPROXIMATELY 12 INCH.THE BUTYL RUBBER TAPE MUST EXTEND 2 TO 3 JL BJ <br /> INCHES(THE TAPE WIDTH)PAST THE ELECTRICAL TAPE AND COME IN GOOD CONTACT WITH THE UNDERLYING CABLE.ON 20. MATERIALS,PRODUCTS AND EQUIPMENT,INCLUDING ALL COMPONENTS THEREOF,SHALL BE NEW AND SHALL APPEAR ON THE LIST OF U.L <br /> 3. GROUT SHALL HAVE A MINIMUM COMPRESSIVE STRNGTH OF 3,000 PSI AT 28 DAYS. CONNECTORS,WHEN WEATHERPROOFING FROM THE MAIN LINE TO THE JUMPER,BUILD UP THIS AREA WITH EXTRA BUTYL APPROVED ITEMS AND SHALL MEET OR EXCEED THE REQUIREMENTS OF THE NEC,NEMA AND IEEE. <br /> RUBBER TAPE TO INSURE A SMOOTH TRANSITION FREE OF VOIDS AND AIR PACKETS DOWN TO THE SMALLER DIAMETER CABLE. <br /> 4. ALL CELLS CONTAINING REINFORCING STEEL OR EMBEDDED ITEMS AND ALL CELLS IN RETAINING WALLS STEP 3:WRAP CONNECTOR/GROUND KIT WITH TWO LAYERS OF BLACK ELECTRICAL TAPE 2 INCH WIDTH OVERLAPPING EACH 21. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS OR MANUFACTURES CATALOG INFORMATION OF ANY/ALL LIGHTING FIXTURES,SWITCHES AND LICENSURE: <br /> AND WALLS BELOW GRADE SHALL BE SOLID GROUTED. ROW BY i INCH.THESE LAST TWO LAYERS MUST BE WRAPPED USING A SHINGLED EFFECT.THE TOP LAYER SHALL BE WRAPPED ALL OTHER ELECTRICAL ITEMS FOR APPROVAL BY THE CONSTRUCTION MANAGER PRIOR TO INSTALLATION. <br /> 5. ALL HORIZONTAL REINFORCEMENT SHALL BE PLACED IN BOND BEAM OR LINTEL BEAM UNITS. SO THAT THE ENDS ARE IN THE UPWARD DIRECTION CREATING A SHINGLED EFFECT WITH THE TAPE SO WATER WILL BE 22, ANY CUTTING OR PATCHING DEEMED NECESSARY FOR ELECTRICAL WORK IS THE ELECTRICAL CONTRACTORS RESPONSIBILITY AND SHALL BE <br /> REPELLED AND NOT ALLOWED TO COLLECT AND POOL THESE TOP LAYERS OF ELECTRICAL TAPE MUST EXTEND TWO INCHES INCLUDED IN THE COST FOR WORK AND PERFORMED TO THE SATISFACTION OF THE'CONSTRUCTION MANAGER'UPON FINAL ACCEPTANCE. ).'{11OM <br /> 6. WHEN GROUTING IS STOPPED FOR ONE HOUR OR LONGER,HORIZONTAL CONSTRUCTION JOINTS SHALL BE (THE TAPE WIDTH)PAST THE BUTYL RUBBER TAPE ONTO THE UNDERLYING CABLE. Q,.OF wnsy 94, <br /> FORMED BY STOPPING THE GROUT POUR 1-12'BELOW TOP OF THE UPPERMOST UNIT. ALL LAYERS OF TAPE SHALL BE WRAPPED SO THAT NO VOIDS OR AIR PACKETS ARE PRESENT.THE LAST WRAP OF TAPE SHALL 23. THE ELECTRICAL CONTRACTOR SHALL LABEL ALL PANELS WITH ONLY TYPEWRITTEN DIRECTORIES.ALL ELECTRICAL WIRING SHALL BE THEA ' I <br /> NOT BE PULLED OR STRETCHED.ALL TAPE SHALL BE CUT WITH A SHARP KNIFE OR SCISSORS. RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. Tom/) ~c O <br /> 7. ALL BOND BEAM BLOCK SHALL BE*DEEPCUT'UNITS. - z <br /> D. SELF-AMALGAMATING TAPE INSTALLATION PROCEDURE: 24. DISCONNECT SWITCHES SHALL BE H.P.RATED HEAVY-DUTY,QUICK-MAKE AND QUICK-BREAK ENCLOSURES,AS REQUIRED BY EXPOSURE TYPE. <br /> 8. PROVIDE INSPECTION AND CLEAN-OUT HOLES AT BASE OF VERTICAL CELLS HAVING GROUT UFTS IN EXCESS A A 37041 <br /> OF 4'-0"OF HEIGHT. 1. REQUIRED MATERIAL:SELF-AMALGAMATING TAPE-1.5 INCHES WIDE AND BLACK ELECTRICAL TAPE-2INCHES WIDE. 25. ALL CONNECTIONS SHALL BE MADE WITH A PROTECTIVE COATING OF AN ANTI-OXIDE COMPOUND SUCH AS'NO-OXIDE A'BY DEARBORNE ,/#.7S'IYlI w <br /> CHEMICAL CO.COAT ALLWIRE SURFACES BEFORE CONNECTING.EXPOSED COPPER SURFACES,INCLUDING GROUND BARS,SHALL BE s5'pll,�tiTt-'� <br /> 9. ALL GROUT SHALL BE CONSOLIDATED WITH A MECHANICAL VIBRATOR. 2. REQUIRED TOOLS:KNIFE OR SCISSORS. TREATED-NO SUBSTITUTIONS. <br /> 10. CEMENT SHALL BE AS SPECIFIED FOR CONCRETE. STEP 1:THOROUGHLY CLEAN AND DRY THE SURFACE OF COAXIAL CABLE AND CONNECTOR TO REMOVE ALL GREASE AND 26. REACEWAYS:CONDUIT SHALL BE SCHEDULE 40 PVC MEETING OR EXCEEDING NEMA TC2-1990.CONTRACTOR SHALL PLUG AND CAP EACH END <br /> DIRTOF SPARE AND EMPTY CONDUITS AND PROVIDE TWO SEPARATE PULL STRINGS-200 LBS TEST POLYETHYLENE CORD.ALL CONDUIT BENDS EQUIPMENT: <br /> 11. REINFORCING BARS-SEE NOTES UNDER'STRUCTURAL CONCRETE NOTES"FOR REQUIREMENTS. . SHALL BE A MINIMUM OF 2 FT.RADIUS.RGS CONDUITS WHEN SPECIFIED,SHALL MEET UL-6 FOR GALVANIZED STEEL,ALL FITTINGS SHALL BE <br /> STEP 2:START WRAPPING SELF-AMALGAMATING TAPE ON THE CABLE AT LEAST 21NCHES FROM THE CONNECTOR/GROUND KIT. SUITABLE FOR USE WITH THREADED RIGID CONDUIT.COAT ALL THREADS WITH'BRITE ZINC OR'GOLT CALV. INSTALL(3)NEW ANTENNAS 8(3)NEW EQUIPMENT. <br /> 12. PROVIDE ONE BAR DIAMETER(A MINIMUM OF 12")GROUT BETWEEN MAIN REINFORCING AND MASONRY MAKE SURE TAPE IS STRETCHED TIGHT DURING THIS APPLICATION. <br /> UNITS. 27. SUPPORT OF ALL ELECTRICAL WORK SHALL BE AS REQUIRED BY NEC. <br /> STEP 3:WHILE STRETCHING TAPE,MAKE ONE WRAP OF THE TAPE AROUND THE CABLE,MAKING SURE THE TAPE IS WRAPPED <br /> 13. LOW UFT CONSTRUCTION,MAXIMUM GROUT POUR HEIGHT IS 4 FEET. ONTO ITSELF.THE TAPE WILL ONLY ADHERE TO ITSELF. 28. CONDUCTORS:CONTRACTOR SHALL USE 98%CONDUCTIVITY COPPER WITH TYPE THWN INSULATION,600 VOLT,COLOR CODED.USE SOLID <br /> 14. HIGH LIFT GROUTED CONSTRUCTION MAYBE USED IN CONFORMANCE WITH PROJECT SPECIFICATIONS AND STEP 4:CONTINUE WRAPPING THE CABLE AND CONNECTOR/GROUND KIT USING HALF OVERLAP(0.75 INCH WIDE)LAYERS. CONDUCTORS FOR WIRE UP TO AND INCLUDING NO.8 AWG.USE STRANDED CONDUCTORS FOR WIRE ABOVE NO.8 AWG. DRAWING INFORMATION: <br /> SECTION 2104.6.1 OF U.B.C. STEP 5:WRAP OVER AND PAST THE CONNECTOR/GROUND KIT AT LEAST 2 INCHES. 29, CONNECTORS FOR POWER CONDUCTORS:CONTRACTOR SHALL USE PRESSURE TYPE INSULATED TWIST-ON CONNECTORS FOR NO.10 AWG DO NOT SCALE DRAWINGS.CONTRACTOR MUST VERIFY <br /> STEP 6:TO TERMINATE THE SELF-AMALGAMATING TAPE,WRAP THE TAPE AT LEAST ONE FULL ROUND OVER THE CABLE AND SMALLER.USE SOLDERLESS MECHANICAL TERMINAL LUGS FOR NO.8 AWG AND LARGER. ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY <br /> 15. ALL CELLS IN CONCRETE BLOCKS SHALL BE FILLED SOLID WITH GROUT,EXCEPT AS NOTEED IN THE STRETCHING THE TAPE TIGHT.CUT THE TAPE USING KNIFE R SCISSORS AND APPLY THE LOOSE END TO THE UNDERLYING ERRORS AND OMISSIONS.ALL PREVIOUS ISSUES OF THIS <br /> DRAWINGS OR SPECIFICATIONS. SELF-AMALGAMATINGTRETCSTRETCHING <br /> THETA TAPE USING THUMB PRESSURE. 30, SERVICE:240/120V,SINGLE PHASE,3 WIRE CONNECTIONS AVAILABLE FROM UTILITY COMPANY.OWNER OR OWNERS AGENT WILL APPLY FOR DRAWING ARE SUPERSEDED BY THE LATEST REVISION. <br /> POWER. THE INFORMATION CONTAINED IN THIS SET OF <br /> 16. CELLS SHALL BE IN VERTICAL ALIGNMENT,DOWELS IN FOOTINGS SHALL BE SET TO ALIGN WITH CORES STEP 7:TWO ROWS OF SELF-AMALGAMATING TAPE SHALL BE APPLIED IN THIS MANNER,IN ALTERNATING DIRECTIONS.THE TOP DOCUMENTS IS PROPRIETARY BY NATURE.ANY USE OR <br /> CONTAINING REINFORCING STEEL. LAYER SHALL BE WRAPPED SO THAT THE ENDS ARE IN AN UPWARD DIRECTION CREATING A SHINGLED EFFECT WITH THE TAPE 31, TELEPHONE SERVICE:CONTRACTOR SHALL PROVIDE EMPTY CONDUITS WITH PULL STRINGS AS INDICATED ON DRAWINGS. DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED <br /> SO WATER WILL BE REPELLED. CLIENT IS STRICTLY PROHIBITED. <br /> 17. REFER TO ARCHITECTURAL DRAWINGS FOR SURFACE AND HEIGHT OF UNITS,LAYING PATTER AND JOINT 32. ELECTRICAL AND TELCO RACEWAYS TO BE BURIED A MINIMUM OF 2 DEPTH. <br /> TYPE STEP 8:WRAP OVER SELF-AMALGAMATING TAPE WITH TWO LAYERS OF BLACK ELECTRICAL TAPE-2INCH WIDTH OVERLAPPING DRAWING TITLE: <br /> EACH ROW BY 1 INCH.THESE TOP TWO LAYERS MUST ALSO BE WRAPPED USING A SHINGLED EFFECT.THE LAYERS SHALL BE 33. CONTRACTOR SHALL PLACE TWO LENGTHS OF WARNING TAPE AT A DEPTH OF 12"BELOW GROUND AND DIRECTLY ABOVE ELECTRICAL AND <br /> 18. SAND SHALL BE CLEAN,SHARP AND WELL GRADED,FREE FROM INJURIOUS AMOUNTS OF DUST,LUMPS, WRAPPED SO THAT THE ENDS ARE IN THE UPWARD DIRECTON CREATING A SHINGLED EFFECT WITH THE TAPE SO WATER WILL TELCO SERVICE CONDUITS.CAUTIONS TAPE TO READ"CAUTION BURIED ELECTRIC'OR BURIED TELECOM". <br /> SHALE,ALKAU OR ORGANIC MATERIAL. BE REPELLED AND NOT ALLOWED TO COLLECT AND POOL.THESE TOP LAYERS OF ELECTRICAL TAPE MUST EXTEND TWO <br /> INCHES(THE TAPE WIDTH)PAST THE SELF-AMALGAMATING TAPE ONTO THE UNDERLYING CABLE.ALL LAYERS OF TAPE SHALL 34. ALL BOLTS SHALL BE STAINLESS STEEL. <br /> 19. BRICK SHALL CONFORM TO ASTM C-62 AND SHALL BE GRADE MW OR BETTER. BE WRAPPED SO THAT NO VOIDS OR AIR PACKETS ARE PRESENT.THE LAST WRAP OF TAPE SHALL NOT BE PULLED OR GENERAL NOTES <br /> STRETCHED.ALL TAPE SHALL BE CUT WITH A SHARP KNIFE OR SCISSORS. <br /> DRAWING NUMBER: <br /> G - 1 <br />