Laserfiche WebLink
4 cN^U^KAICU <br /> N Al TH DJUP ICT <br /> WWW.SNOHD.ORG Environmental Health Division <br /> September 25, 2015 <br /> Mike Clift <br /> RJC Construction Inc. <br /> 15415 SE Orient Dr <br /> Boring, OR 97009 <br /> Subject: Proposed Remodel Starbucks, Fred Meyer#458, 12906 Bothell-Evt Hwy, Everett <br /> Dear Mr. Clift: <br /> Your plans have been reviewed with the Rules and Regulations of the State Board of Health, and with <br /> the policies of the Snohomish Health District. With the addition of the following conditions, the plans <br /> are approved. <br /> 1. The conditional approval of the plans for Starbucks was based upon the plans submitted <br /> September 21, 2015, and the menu submitted August 21, 2015. Any changes to these items <br /> will void this approval. <br /> 2. Three-compartment sinks must be NSF or equivalent listed with rounded corners and integral <br /> drainboards at both ends. The basins of the three-compartment sink must be large enough to fit the <br /> largest item needing to be washed. <br /> 3. An indirect waste drain (an air gap) is required for the three-compartment sink, ice machine, running <br /> water dipper well, espresso machine, and any equipment in which food is placed. Please note that a <br /> direct drain to a grease trap is not considered an indirect drain even if the grease trap is indirectly <br /> drained. <br /> 4. A dipper well is indicated at the pitcher rinse sink. The pitcher rinse sink will be used for that <br /> purpose only. <br /> 5. A horizontal separation of at least 16 inches or a vertical partition 16 inches in height is required <br /> between the handwash sink and the three compartment sink. <br /> 6. When splashguards (partitions and/or walls) are provided on both sides of a handwash sink, the <br /> distance between the splashguards must be at least 18 inches apart (shoulder width) to allow <br /> proper access to the handwash sink. <br /> 7. Water heaters must be of sufficient size to provide hot water to dishwasher and/or scullery sinks <br /> and at the same time provide hot water to all handwash sinks. <br /> 8. Hot water must be available to all handwash sinks within 15 seconds. The hot water for the facility <br /> must not be used, at any plumbing fixture, for a minimum of 6 hours prior to the preoperational <br /> inspection. This is required so that proper testing of the 15-second time requirement for hot water <br /> availability can be completed. <br /> 9. All food service equipment, both new and used, must be listed by the National Sanitation <br /> Foundation (NSF) or equivalent for its intended use. Used and new refrigeration must be capable of <br /> holding food at temperature of 41 OF or below. <br /> 10. Used equipment is subject to onsite inspection to determine acceptability for use in the proposed <br /> food service establishment. Used equipment must be clean, in proper operating condition, and in <br /> good repair. Used refrigeration must be capable of holding at a temperature of 41 OF or below. <br /> 11. Extra wall protection is required on walls behind all sinks and food preparation counters and tables. <br /> A 16-inch high backsplash of plastic laminate, fiberglass-reinforced plastic or equal is acceptable. A <br /> backsplash higher than 16 inches is required on the wall behind counter top equipment taller than <br /> 16 inches. Wall protection behind mop sinks must cover the entire splash zone. Plastic coated <br /> hardboard is not acceptable. <br /> 3020 Rucker Avenue, Suite 104 0 Everett, WA 98201-3900 ■ tel: 425.339.5250 E fax: 425.339.5254 <br />