GROUNDING KEYED NOTES <br /> OEXISTING GROUND BUSS BAR,TYP. ^^ Q� <br /> �/l�x.71 <br /> Your world. Delivered. <br /> PLANS PREPARED BY: <br /> EXISTING#t2 STRANDED GREEN INSULATED COPPER GROUND LEAD FROM <br /> $ NE <br /> GROUND BUSS BAR TIED INTO THE EXISTING GROUNDING SYSTEM. __� COrl7NE75TO <br /> O PROPOSED LUG GROUND CONNECTION TO EQUIPMENT.SEE DETAIL 9/E-1.1 16928 WOODINVILLE-REDMOND RD NE.SUITE 210 <br /> WOODINVILLE,WA 98072 <br /> PHONE:425.487.1732 <br /> WNW.CORNERSTONE{NGRCOM <br /> 1 9 PROJECT INFO: <br /> 5 6 OPROPOSED#2 STRANDED GREEN INSULATED COPPER GROUND LEAD FROM SN05 <br /> EQUIPMENT TO GROUND BUSS BAR. <br /> PAINE FIELD <br /> ' <br /> 1118 BOTH ST SW <br /> D O O <br /> O EVERETT,WA 98203 <br /> SNOHOMISH COUNTY <br /> o ISSUED FOR: <br /> ` O L CONSTRUCTION <br /> REV:DATE:=ISSUEDFOR: BY: <br /> GROUNDING NOTES <br /> 1. ALL DETAILS ARE SHOWN IN GENERAL TERMS.ACTUAL INSTALLATION AND OQ 10-27-16 FINAL DRA <br /> LATTICE <br /> .1 T 'HIGH CONSTRUCTION MAY VARY DUE TO SITE SPECIFIC CONDITIONS. <br /> 9 LATOWER Q 10-26-16 PRELIMINARY JRS <br /> o 2. GROUND ALL ANTENNA BASES,FRAMES,CABLE RUNS,AND OTHER METALLIC <br /> o COMPONENTS USING GROUND WIRES AND CONNECT TO SURFACE MOUNTED <br /> D BUS BARS.FOLLOW ANTENNA AND BTS MANUFACTURER'S PRACTICES FOR A 09-26-16 PRELIMINARY JRS <br /> 6 GROUNDING REQUIREMENTS.GROUND COAX SHIELD AT BOTH ENDS AND EXIT <br /> FROM TOWER OR POLE USING MFR'S PRACTICES- DRAWN BY: CHK: APV.: <br /> L JRS MWO MWO <br /> 3. ALL GROUND CONNECTIONS SHALL BE CADWELD.ALL WIRES SHALL BE CURRENT ISSUE DATE: <br /> COPPER THHN/THWN.ALL GROUND WIRE SHALL BE GREEN INSULATED WIRE r <br /> 5 ABOVE GROUND. L 10_27_16 <br /> 4. CONTRACTOR TO VERIFY AND TEST GROUND TO SOURCE.GROUNDING AND LICENSURE: <br /> DD OTHER OPERATIONAL TESTING WILL BE WITNESSED BY AT&T WIRELESS,LLC. <br /> 1 O REPRESENTATIVE. <br /> o ISLE <br /> 5. REFER TO DIVISION 16 GENERAL ELECTRIC;GENERAL ELECTRICAL PROVISION kyc O� <br /> AND COMPLY WITH ALL REQUIREMENTS OF GROUNDING STANDARDS. Q Q� <br /> 1 6. ELECTRICAL CONTRACTOR TO PROVIDE DETAILED DESIGN OF GROUNDING <br /> SYSTEM,AND RECEIVE APPROVAL OF DESIGN BY AUTHORIZED AT&T <br /> WIRELESS,LLC.REPRESENTATIVE,PRIOR TO INSTALLATION OF GROUNDING 3 <br /> SYSTEM. PHOTO DOCUMENT ALL CADWELDS AND GROUND RING � L <br /> o D 6 7. NOTIFY CONSTRUCTION MANAGER IF THERE ARE ANY DIFFICULTIES JURISDICTIONAL APPROVAL: <br /> D INSTALLING GROUNDING SYSTEM DUE TO SITE SOIL CONDITIONS. <br /> O <br /> 9 <br /> PROPRIETARY INFORMATION: <br /> DO NOT SCALE DRAWINGS.CONTRACTOR MUST VERIFY <br /> ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY <br /> ERRORSANDOMISSIONS ALL PREVIOUS ISSUES OF THIS <br /> DRAWING ARE SUPERSEDED BY THE LATEST REVISION. <br /> THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS <br /> LEGEND IS PROPRIETARY BY NATURE.ANY USE OR DISCLOSURE <br /> OTHER THAN WHICH IS RELATED TO NAMED CUENT IS <br /> STRICTLY PROHIBITED. <br /> SYMBOL DESCRIPTION DRAWING TITLE: <br /> NOTE: (a GROUND INSPECTION WELL SCHEMATIC GROUNDING PLAN <br /> ALL GROUNDING WIRE RUNS AND � � ® COPPER GROUND ROD <br /> DRAWING NUMBER: <br /> CONNECTIONS,BOTH ABOVE AND U ® COMPRESSION LUG <br /> BELOW GRADE,SHALL BE LOCATED u <br /> INSIDE OF THE LEASE AREA LINE. E-1 PLAN NORTH ® CADWELD CONNECTION -� '�—® ® O <br /> 1 <br /> SCHEMATIC GROUNDING PLAN SIDE SPLICE CADWELD <br /> 22x34 SCALE:3/4"=V-0" 111x17 SCALE:3/8"=V-0" \1�° FIELD VERIFY&TIE INTO EXISTING GROUNDING SYSTEM CEI JOB NUMBER: BWE 16-09089 <br />