Laserfiche WebLink
44 MODULE PV ARRAY— 13.2kW STC SYSTEMCOMPLIES WITH NOTES: <br /> (2 Strings of 17, 1 string of 10 modules) 1. ALL SERIES CONNECTED PV MODULES SHALL BE INTERCONNECTED WITH MANUFACTURER <br /> Series String characteristics RAPID SHUTDOWN AND SUPPLIED MC-4 GENERATION 2, LOCKING CONNECTORS. <br /> *Voc:500,Vmpp=350v, Impp=15aDC Imax=15.5aDC REQUIRED LABELING. 2. PV SOURCE CIRCUIT JUNCTION BOX SHALL BE LOCATED ON THE ROOF AND NEMA 3R RATED. <br /> r — — — _ _ __' —_—' RAPID SHUTDOWN IS 3. ALL WIRES FROM ROOF JUNCTION BOX TO INVERTER SHALL BE 10AWG.THHN-2 AND IN CONDUIT TO <br /> INITIATED BY LOSS OF MEET NEC CODE AND LIMIT VOLTAGE DROP TO LESS THAN 2%. <br /> II I 1 I UTILITY POWER. 4. WIRING IN DC CIRCUITS TO BE RATED 600V-90C, EXPOSED CABLES SUNLIGHT RESISTANT, <br /> PV Module 1 PV Module 1 PV Module 1 I 5. PV SYSTEM Voc SHALL NEVER EXCEED 600 VDC (using historic lowest temperature for safety factor). <br /> + + 6. INVERTERS INTEGRAL, LOCKABLE DC DISCONNECT SHALL BE USED AS THE PV SYSTEM DC <br /> + DISCONNECT. <br /> ( � I MARKING/LABELING 7. INVERTER SHALL BE LOCATED NEAR THE BILLING METER, WITH THE PV SYSTEM COMPONENTS <br /> PER NEC 690 CLEARLY LABELED. <br /> I 8. PRODUCTION METER SHALL BE LOCATED NEAR THE BILLING METER. <br /> 9.WIRING FROM INVERTER TO SOLAR METER AND PANEL SHALL BE THWN IN CONDUIT. / <br /> eC M M I 10. PV MODULE CONTINUOUS GROUNDING CONDUCTOR SHALL BE UNIRAC UUETL LISTED Rl// <br /> a a i a ITEK 300SE-B/W MOUNT GROUNDING TO RACKING SYSTEM. A,j <br /> I I PV Modules 11. PV RACKING GROUNDING ELECTRODE CONDUCTOR SHALL BE#6 CONTINUOUS COPP ,y <br /> 300W/32.9V/9A 2 .> <br /> I I / <br /> j Voc=39.8v, Isc=9.7A Y OF <br /> SOLAR kWh METER P' rJnit Se � E <br /> I I I 8 /c <br /> is <br /> 5 320 AMP SERVICE <br /> I <br /> L1 L2 Meter#: 1000508343 <br /> Zigbee wireless to n 120/240 VAC 1:0' <br /> I � • reciever near router '19 <br /> Meter <br /> j N #6AWG CU OR _ <br /> Ll <br /> M� <br /> —c <br /> a' - Red- <br /> GREATER - L2j <br /> to PV Wire I N <br /> I I <br /> UngroundedSolarEdge SE11400 6oA <br /> DC conductors GFDI ' PV Service <br /> PROTECTION INVERTER Disconnect 00 <br /> I ( I 2 + D <br /> / <br /> /� _ — : — AC OUTPUT p anel <br /> _ _ _ . _ O — — _ ___ 60 amp utility <br /> ------ <br /> _._.._INE 2 _.. <br /> E - - - - - - AC disconnect <br /> • o o • o _ _ _ AC (locking, visible O <br /> PV Module 1 a V Module 17 a V Module 10 a _ _ _ LINE break) <br /> + + + • - - <br /> - N' <br /> F-1 ❑ ❑ <br /> Neutral O G <br /> DC 240 VAC 10 I <br /> 6 DISCONNECT 60HZ, <br /> - Black- ------------------SWJTCN------------- 47.5AAC max ------------------------- f <br /> - PV Wire j 1140OWmp GND ROD <br /> CONFIDENTIAL,PROPERTY OF <br /> Utility: PSE SUNERGY SYSTEMS Sunergy Systems <br /> Customer: 4546 Leary Way NW <br /> AHJ: L&I Pierre Seattle,WA 98107 <br /> - t ------------------------------ Rid 2/21/17 <br /> -T------------------ se <br /> ev <br /> - I � , . Project: <br /> i Jon Lan e, NABCEP <br /> 10 b Drawn By: 13.2 kW Itek/SolarEdge Photovoltaic system <br /> Jon Lange, NABCEP Address: Title/Part/Descrition: <br /> MODULE EQUIPMENT CONTINUOUS Grounding Electrical Engineer Approval: 8016 Beverly Blvd., PV ELECTRICAL <br /> GROUND—UL listed/NEC Electrode Conductor— Howard Lamb, MSEE Everett,WA 98203 <br /> compliant, Unirac Ground 11 #6 awg, bare Copper Zigbee card plugs into Date: 02/21/17 CONFIGURATION DRAWING <br /> system inverter and antenna En ineer: <br />