o r- <br /> M <br /> o <br /> N <br /> CODES <br /> GENERAL NOTES <br /> U) <br /> PROJECT SHALLCONFORM TO 2012 EDITION I.B.C.AND CODES OF ALL AUTHORITIES HAVING JURISDICTION. 6.EACH ROOM SHALL BE PROVIDED WITH FRESH AIR INLET DUCTS WITH A MINIMUM OF 4 SQ.IN. <br /> VERIFICATION 7.PROVIDE A CIRCULATION AIR SUPPLY OPENING OR DUCT OF 2 SQUARE INCHES PER 1000 BTU FOR FORCED <br /> AIR FURNACE. O <br /> CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO COMMENCEMENT OF WORK. <br /> IMMEDIATELY NOTIFY DESIGNER OF ANY DISCREPANCIES,OMISSIONS OR IRREGULARITIES. 8.OUTDOOR AIR INLETS SHALL NOT BE PLACED IN THE FOLLOWING LOCATIONS: Z <br /> DESIGN CRITERIA (A) CLOSER THAN 10 FEET FROM AN APPLIANCE VENT,UNLESS SUCH VENT OUTLET IS 3 FEET ABOVE INLET. J <br /> UNLESS NOTED OTHERWISEROOF 40 PSF(15 DL+25 LL) (8)WHERE IT WILL PICK UP OBJECTIONABLE ORDERS,FUMES OR FLAMMABLE VAPORS. <br /> FLOOR 50 PSF(10 DL+40 LL) (C)A HAZARDOUS OR UNSANITARY LOCATION. <br /> ING APPLIANCES. Q� <br /> FOUNDATION EXT.DECKS 65 PSF(5 DL+60 LL) OR SPACE IL1NG JEDUCPN <br /> 9.EXHAUST DUCTSHALL BE L81 LISTED <br /> TERMIN TE A MIN.OF 36"AWAY FROM ALL OPENINGS W <br /> 1.ALL FOOTINGS SHALL BEAR ON UNDISTURBED SOIL WITH BEARING CAPACITY OF 2000 PSF MIN. HAVE R-4 INSULATION VALUE IN UNCONDITIONED SPACES z <br /> 2.EXTERIOR FOOTINGS SHALL BEAR ON NON ORGANIC UNDISTURBED SOIL,A MINIMUM OF V-6"BELOW GRADE. SAFETY GLAZING W <br /> 3.CONCRETE SHALL BE Ft=2500psi WITH A MINIMUM 5\SACKS PER CUBIC YARD MIX. PROVIDE PERMANENTLY MARKED SAFETY GLAZING AT THE FOLLOWING LOCATIONS PER 2012 IBR.C. �T�► <br /> 4.REINFORCING STEEL SHALL BE ASTM A-615,GRADE 40-#4,GRADE 60-#5 OR LARGER. 1.IN ANY OPERABLE DOOR,SWINGING OR SLIDING. 0 <br /> S.COVER REINFORCING STEEL WITH 1\"OF CONCRETE. 3"WHEN POURED IN DIRECT CONTACT WITH EARTH. 2.SHOWER AND BATHTUB ENCLOSURES/HOT TUB/SAUNA w/BOTTOM EDGE LESS THAN 60"ABOVE FLOOR DRAIN. <br /> 6.VERIFY THAT FOUNDATION VENTS DO NOT INTERFERE WITH STRUCTURAL HARDWARE OR SYSTEMS. 3.WINDOWS LOCATED WITHIN A 24"ARC OF EITHER VERTICAL EDGE OF A CLOSED DOOR,WHEN THE <br /> FRAMING BOTTOM EDGE OF THE WINDOW IS WITHIN 60"ABOVE THE FLOOR. <br /> DEFERRED SUBMITTAL FOR TRUSSES SHALL BE SUBMITTED TO THE BUILDING DEPARTMENT 4.GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL,OTHER THAN THOSE LOCATIONS <br /> FOR REVIEW AND APPROVAL. DESCRIBED IN ITEMS 5 AND 6,THAT MEETS ALL OF THE FOLLOWING CONDITIONS: <br /> ALL SCALED TRUSS DRAWINGS SHALL BE REVIEWED BY THE ARCHITECT/ENGINEER OF RECORD 4.1 EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQUARE FEET. <br /> PRIOR TO SUBMITTAL TO THE JURISDICTION FOR THEIR REVIEW AND APPROVAL. 4.2 EXPOSED BOTTOM EDGE LESS THAN 18 INCHES ABOVE THE FLOOR. <br /> 1.ALL LUMBER SHALL BE PER WWPA STANDARDS: 4.3 EXPOSED TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR. Lij <br /> JOISTS&RAFTERS HF#2 OR BETTER 4.4 ONE OR MORE WALKING SURFACES WITHIN 36 INCHES HORIZONTALLY OF THEM <br /> SAWN BEAMS DF#2 OR BETTER PLANE OF THE GLAZING. U > o <br /> GLULAM BEAMS 24f-V4 S.GLAZING IN GUARDRAILS. <br /> MICROLAMS 1.9E 6.GLAZING IN STAIR WELLS WINDOWS REQUIRED AT LOWER LANDINGS BUT NOT AT UPPER 0 m 00 <br /> PARALLAMS 2.0E LANDINGS PER 2012 I.B.C.SECTION R308.4 C') <br /> COLUMNS DF#1 OR BETTER MISCELLANEOUS (10U <br /> 2.TRUSSES SHALL BE DESIGNED BY A LICENSED WASHINGTON STATE ENGINEER. 1.110 VOLT SMOKE DETECTORS w/BATTERY BACKUP&INTERCONNECTED AT THE FOLLOWING LOCATIONS PER 2012 (� <br /> 3.WOOD IN DIRECT CONTACT WITH EARTH OR MASONRY SHALL BE PRESSURE TREATED. <br /> 4.EXTERIOR DECKS SHALL BE CONSTRUCTED OF PRESSURE TREATED OR DECAY RESISTANT WOOD. I.B.C. ONE PER SLEEPING ROOM,OUTSIDE EACH SLEEPING AREA IN THE IMMEDIATE VICINITY OFTHE BEDROOMS, elf <br /> AND ONE EACH ADDITIONAL TORY OF DWELLING,INCLUDING BASEMENT. <br /> 5.PROVIDE SOLID FIRE BLOCKING AT STUDS OVER 10',ROOF/WALL INTERSECTIONS. W m <br /> 6.ALL NAILING TO BE PER ENGINEER'S NOTES OR PER CHAPTER 6-1 I.R.C. <br /> 2.WATER HEATERS SHALL BE SECURED TO FRAMING WITH(2)GALVANIZED SEISMIC STRAPS. <br /> J <br /> 7.ALL STRUCTURAL PANEL COMPONENTS,WITHIN THE CONDITIONED SPACE,SUCH AS PLYWOOD,PARTICLE 3.WATER HEATER PRESSURE RELIEF VALVES SHALL BE PLUMBED TO EXTERIOR. w o <br /> BOARD,WAFER BOARD AND O.S.B.SHALL BE IDENTIFIED AS"EXPOSURE I"OR"EXTERIOR". 4.ALL GAS BURNING APPLIANCES SHALL HAVE PILOT LIGHTS AND BURNERS MORE THAN 18"ABOVE FLOOR. N <br /> INSULATION 5.EGRESS WINDOWS SHALL HAVE A SILL HEIGHT NO MORE THAN 44"ABOVE FLOOR. 3: N j <br /> 6.AN ESCAPE WINDOW IS REQUIRED FROM ALL BASEMENTS WITH HABITABLE SPACE. co of <br /> 1.HEATED BUILDING ENVELOPES SHALL CONFORM TO 2012 7.GARAGES SHALL BE SEPARATED FROM RESIDENCE AS FOLLOWS:PER 2012 I.B.C.RESIDENCE AND ITS ATTIC w/ W <br /> TABLE 6-1(PRESCRIPTIVE METHOD)OR AN ENERGYY ANALYSIS. NOT LESS THAN 1/2"'TYPE'X'G.W.B.APPLIED ON GARAGE SIDE.HABITABLE ROOMS ABOVE w/5/8"TYPE'X'G.W.B. <br /> 3.PROVIDE 4 mil INTERIOR VAPORR RETARDER OR APPROVED PVA PAINT. � <br /> 2.FACED BATT.INSULATION TO STAPLED AT FFACE. ANY SUPPORTING STRUCTURE OF FLOOR/CEILING ASSEMBLY w/1/2"TYPE'X'G.W.B.4.PROVIDE EXTERIOR MOISTURE BARRIER MEMBRANE(TYVEK OMAINN MAINTAIN MINIMUM 1"CLEAR AIR SPACE. 8.PROVIDE 1/2"TYPE'X'GWB AT ALL ACCESSIBLE SPACES BENEATH STAIRS. <br /> S.EXTEND WIND BAFFLE 12"ABOVE ATTIC INSULATION TO MEQ)OVER EXTERIOR SHEETING. 9,HANDRAILS TO BE 1-1/2"m TO 2" PLACED 34"-38"ABOVE TREAD NOSING.RETURN ENDS TO WALL. <br /> 6.INSULATION SHALL NOT BE COMPRESSED. 10.GUARDRAILS SHALL BE 36"ABOVE FLOOR IN ALL RESIDENTIAL OCCUPANCIES. <br /> 7.WRAP WATER HEATERS WITH POLY FACED R-16 BATT. WATER HEATERS SHALL MEET THE REQUIREMENTS 11.GUARDRAILS SHALL BE CONSTRUCTED SO THAT A 4"m SPHERE CANNOT PASS THROUGH INTERMEDIATE MEMBER. <br /> AND SHALL BE SO LABELED. 12.ELECTRICAL OUTLETS IN ALL BATHROOMS,GARAGES,KITCHENS,AND OTHER APPLICABLE LOCATION PER 2012 ^ <br /> 8.PROVIDE R-10 RIGID INSULATION AT BASE OF WATER HEATERS IN UNHEATED SPACES. I.B.C.SHALL HAVE GFI PROTECTION. U <br /> 9.IN UNHEATED SPACES WRAP CONDITIONING SUPPLY DUCTS WITH R-8 INSULATION,WATER PIPES WITH R-3. 13.SHOWERS TO BE LIMITED TO A 2.5 GPM FLOW. TOILETS TO BE LIMITED TO 1.6 GAL PER FLUSH. LAV FAUCETS N �O �- <br /> 10.INSULATE EXHAUST DUCTS IN UNCONDITIONED SPACES TO R-4. TO BE LIMITED TO 2.5GPM. CD <br /> 11.WEATHER-STRIP AND INSULATE ATTIC ACCESS(MIN.22"x 30")MINIMUM 30"HEADROOM. 14.PROVIDE WALL COVERINGS THAT SHALL BE CEMENT PLATER,TILE OR APPROVED EQUAL TO 70 INCHES ABOVEQ U N <br /> 12.NON-RECIRCULATION HOT AND COLD WATER PIPES LOCATED IN UNCONDITIONED SPACE SHALL BE DRAIN AT SHOWER OR TUBS WITH SHOWERS. WALL COVERINGS SPECIFIED AT SHOWERS. C= ] Co <br /> INSULATED TO R-3 MINIMUM. 15.WOOD STOVES/FIREPLACES SHALL HAVE TIGHT FITTING DOORS AND FLUE DAMPERS,OUTSIDE COMBUSTION <br /> VENTILATION AIR(6")PREFABRICATED FIREPLACE TO BEAR THE STAMP OF AN APPROVED TESTING LAB AND SHALL BE .- <br /> 1.SOURCE SPECIFIC FANS WHICH VENT TO BUILDING EXTERIOR ARE REQUIRED AS FOLLOWS: INSTALLED IN ACCORDANCE WITH THE TERMS OF THEIR LISTING AND THE MANUFACTURES INSTRUCTIONS. (D <br /> BATH,LAUNDRY&POWDER ROOMS 50 CFM 16.ALL PENETRATIONS THROUGH FLOORS OR CEILING SHALL BE CAULKED AND SEALED. 0 <br /> KITCHEN RANGE 100 CFM 17.EXTERIOR OPENINGS EXPOSED TO THE WEATHER SHALL BE FLASHED IN SUCH A MANNER AS TO MAKE THEM <br /> 2.WHOLE HOUSE FANS MUST PROVIDE A MINIMUM OF.35 AIR CHANGES PER HOUR(MAXIMUM OF.5 ACH)AND MUST WATERPROOF. Lu <br /> PROVIDE A MIN.OF 15CFM FOR EACH BEDROOM AND AN ADDITIONAL 15CFM FOR OTHER AREAS COMBINED. 18.OPENINGS FROM A PRIVATE GARAGE AND RESIDENCE SHALL BE 13/8"MINIMUM THICKNESS,SOLID-CORE OR 3.WHOLE HOUSE'AN MUST BE CONTROLLED BOTH BY AN AUTOMATIC TIMER AND A MANUAL SWITCH. HONEYCOMB STEEL DOOR,OR 20 MINUTE LABELED PER 2012 I.B.C. <br /> 4.WHOLE HOUSE FANS LOCATED WITHIN 4'OF THE CEILING MUST HAVE A SONE RATING OF 1.5 OR LESS. 19.ROOF/VALLEY&ROOF/VERTICAL SURFACES SHALL BE FLASHED/COUNTER FLASHED WITH MIN.26 GA. N N W <br /> S.ALL EXHAUST FANS SHALL HAVE A TIGHT FITTING BACK DRAFT DAMPER. GALVANIZED. CV <br /> U <br /> i <br /> Q <br />