My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5405 BROADWAY 2025-11-24
>
Address Records
>
BROADWAY
>
5405
>
5405 BROADWAY 2025-11-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/24/2025 10:39:14 AM
Creation date
6/9/2017 1:52:10 PM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
5405
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
67
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Sound Structural Solutions, Inc Title 8' C(35 2000 50)(S C=8) Page: <br /> f www.ssseng•.com Job# Dsgnr: Date: FEB 12,2009 <br /> Description.... <br /> This Wall in File: S:\Templates\Retaining Walls\081028 fwc <br /> Retain Pro 2007,24-Jul-2008,(c)1989-2008 <br /> www.retainpro.com/support for latest release Cantilevered Retaining Wall Design Code: IBC 2006 <br /> Registration#:RP-1177245 RP2007-N <br /> Criteria Soil Data Footing Dimensions &Strengths <br /> Retained Height = 8.00 ft Allow Soil Bearing = 2,000.0 psf Toe Width 3.00 ft <br /> Wall height above soil = 0.00 ft Equivalent Fluid Pressure Method Heel Width _ 1.33 <br /> Heel Active Pressure 35.0 psf/ft Total Footing Width 4.33 <br /> Slope Behind Wall = 0.00: 1 Toe Active Pressure = 0.0 psf/ft Footing Thickness = 10.00 in <br /> Height of Soil over Toe = 4.00 in Passive Pressure = 350.0 psf/ft - <br /> Key Width 0.00 in <br /> Water height over heel = 0.0 ft Soil Density,Heel = 110.00 pcf Key Depth = 0.00 in <br /> Soil Density,Toe 110.00 pcf Key Distance from Toe = 0.00 ft <br /> Wind on Stem = 0.0 psf FootingllSoil Friction = 0.300 fc = 2,500 psi Fy = 60,000 psi <br /> Vertical component of active Soil height to ignore Footing Concrete Density = 150.00 pcf <br /> lateral soil pressure options: for passive pressure = 0.00 in Min.As% = 0.0014 <br /> NOT USED for Soil Pressure. Cover @ Top = 3.00 in @ Btm.= 3.00 in <br /> NOT USED for Sliding Resistance. <br /> USED for Overturning Resistance. <br /> Surcharge Loads Lateral Load Applied to Stem rAdjacent Footing Load <br /> Surcharge Over Heel = 50.0 psf Lateral Load = 0.0#/ft Adjacent Footing Load = 0.0 lbs <br /> Used To Resist Sliding&Overturning ...Height to Top = 0.00 ft Footing Width 0.00 ft <br /> Surcharge Over Toe = 0.0 psf ...Height to Bottom = 0.00 ft Eccentricity - 0.00 in <br /> NOT Used for Sliding&Overtuming Wall to Ftg CL Dist = 0.00 ft <br /> Axial Load Applied to Stem Footing Type Line Load <br /> Base Above/Below Soil = 0.0 ft <br /> Axial Dead Load = 0.0 lbs at Back of Wall <br /> Axial Live Load = 0.0 lbs Poisson's Ratio = 0.300 <br /> Axial Load Eccentricity = 0.0 in <br /> Design Summary Stem Construction Top Stem 2nd <br /> Stem OK Stem OK <br /> Wall Stability Ratios Design Height Above Ftc ft= 2.00 0.00 <br /> Overturning = 1.75 OK Wall Material Above"Ht" = Concrete Concrete <br /> Slab Resists All Sliding! Thickness = 8.00 8.00 <br /> Rebar Size = # 5 # 5 <br /> Total Bearina Load = 2,071 lbs Rebar Spacing = 16.00 8.00 <br /> ...resultant ecc. = 15.32 in Rebar Placed at = Edge Edge <br /> Design Data <br /> Soil Pressure @ Toe = 1,552 psf OK fb/FB+fa/Fa = 0.437 0.520 <br /> Soil Pressure @ Heel = 0 psf OK Total Force @ Section lbs= 1,160.7 1,995.6 <br /> Allowable = 2,000 psf Moment....Actual ft-#= 2,474.2 5,593.2 <br /> Soil Pressure Less Than Allowable <br /> ACI Factored @Toe = 1,863 psf Moment.....Allowable ft-#= 5,663.0 10,751.9 <br /> ACI Factored @Heel = 0 psf Shear.....Actual psi= 17.0 29.2 <br /> = 25.1 psi OK Shear.....Allowable psi= 75.0 75.0 <br /> Footing Shear @Toe <br /> Wall Weight psf= 100.0 100.0 <br /> Footing Shear @ Heel = 18.8 psi OK <br /> = 75.0 psi Rebar Depth 'd' in= 5.69 5.69 <br /> AllowableLAP SPLICE IF ABOVE in= 23.40 23.40 <br /> Sliding CaIcs Slab Resists All Sliding! <br /> Lateral Sliding Force 1,506.0 lbs LAP SPLICE BELOW in= 23.40 <br /> HOOK EMBED <br /> INTO FTG in= 6.00 <br /> Masonry Data <br /> fm psi= <br /> Fs psi= <br /> Solid Grouting = <br /> Use Full Stresses <br /> Load Factors = <br /> Modular Ration' <br /> Building Code IBC 2006 <br /> Short Term Factor <br /> Dead Load 1.200 - <br /> Dead <br /> 1.600 Equiv.Solid Thick.Live _ <br /> Earth,H 1.600 Masonry Block Type = Medium Weight <br /> Masonry Design Method = ASD <br /> Wind,W 1.600 <br /> Seismic,E 1.000 Concrete Data <br /> fc psi= 2,500.0 2,500.0 <br /> Fy psi= 60,000.0 60,000.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.