Laserfiche WebLink
Title 7523 Broadway Page: <br /> P- STATE <br /> L Job# 0575 : Dsgnr: amg Date: 19 MAY 2016 <br /> Description.... <br /> ?zvn3ano z r t >ta+a: LOWER FLOOR RESISTED <br /> This Wall in File:C:\Users\Andy\Documents\UPST8 MAIN\2015(0471-0579)\0575 Adair Enterprises-Plan <br /> RetainPro(c)1987-2015, Build 11.15.11.3 <br /> License:Kw-06060767 . Restrained Retaining Wall Design Code: IBC 2012,AC1 318-11,AC1 530-11 <br /> License To: Upstate Engineering <br /> Criteria Soil Data a c - <br /> t. ...; <br /> Retained Height = 6.00 ft Allow Soil Bearing = 2,000.0 psf <br /> Wall height above soil = 0.50 ft Equivalent Fluid Pressure Method <br /> Total Wall Height = 6.50 ft At-rest Heel Pressure = 35.0 psf/ft <br /> Top Support Height = 3.00 ft Passive Pressure = 305.0 psf/ft <br /> Soil Density = 110.00 pcf s.�. <br /> Slope Behind Wal = 0.00 FootingIlSoil Frictior = 0.400 ,e :«e,,, <br /> Height of Soil over Toe = 0.00 in Soil height to ignore I° 'i" z <br /> for passive pressure = 12.00 in <br /> W roe 7' <br /> r <br /> r�HeB� • , <br /> Thumbnail <br /> Surcharge Loads Uniform Lateral Load Applied to Stem Adjacent Footing Load <br /> Surcharge Over Heel = 50.0 psf Lateral Load = 0.0#/ft Adjacent Footing Load = 0.0 lbs <br /> -Used To Resist Sliding&Overturning _..Height to Top = 0.00 ft Footing Width = 0.00 ft <br /> Surcharge Over Toe = 0.0 psf ...Height to Bottorr = 0.00 ft Eccentricity = 0.00 in <br /> Used for Sliding&Overturning The above lateral load Wall to Ftg CL Dist = 0.00 ft <br /> Axial Load Applied to Stem has been increased 1.00 Footing Type Line Load <br /> by a factor of Base Above/Below Soil <br /> Axial Dead Load = 225.0 lbs at Back of Wall = 0.0 ft <br /> Axial Live Load = 355.0 lbs Wind on Exposed Stem = 0.0 psf <br /> Axial Load Eccentricity = 0.0 in Poisson's Ratio = 0.300 <br /> Earth Pressure Seismic Load Kh Soil Density Multiplier = 0.200 g Added seismic per unit area = 0.0 psf <br /> Stem Weight Seismic Load Fp/W Weight Multiplier = 0.000 g Added seismic per unit area = 0.0 psf <br /> Design Summary Concrete Stem Construction <br /> Total Bearing Load = 1,713 lbs Thickness = 8.00 in Fy = 40,000 psi <br /> ...resultant ecc. = 0.68 in Wall Weight = 100.0 psf fc = 2,500 psi <br /> Soil Pressure @ Toe = 1,142 psf OK Stem is FREE to rotate at top of footing <br /> Soil Pressure @ Heel = 1,142 psf OK <br /> Allowable = 2,000 psf Mmax Between <br /> Soil Pressure Less Than Allowable @ Top Support Top&Base @ Base of Wall <br /> ACI Factored @ Toe = 1,796 psf Stem OK Stem OK Stem OK <br /> ACI Factored @ Heel = 1,135 psf Design Height Above Fto = 3.00 ft 1.02 ft 0.00 ft <br /> Footing Shear @ Toe = 0.2 psi OK Rebar Size = # 4 # 4 # 4 <br /> Footing Shear @ Heel = 0.9 psi OK Rebar Spacing = 10.00 in 10.00 in 10.00 in <br /> Allowable = 75.0 psi Rebar Placed at = Center Center Center <br /> Reaction at Top = 513.2 lbs Rebar Depth 'd' = 4.00 in 4.00 in 4.00 in <br /> Reaction at Bottom = 410.4 lbs Design Data <br /> Sliding Stability Ratio = 1.56 OK fb/FB+fa/Fa = 0.134 0.060 0.000 <br /> Sliding Calcs Mu....Actual = 366.5 ft-# 164.3 ft-# O.Oft-# <br /> Lateral Sliding Force = 410.4 lbs Mn*Phi.....Allowable = 2,744.1 ft-# 2,744.1 ft-# 2,744.1 ft-# <br /> less 100%Passive Force= - 46.6 lbs <br /> less 100%Friction Force= - 685.3 lbs Shear Force @ this height = 496.7 lbs 336.0 lbs <br /> Added Force Req'd = 0.0 lbs OK Shear.....Actual = 10.35 psi 7.00.psi <br /> ....for 1.5 Stability = 0.0 lbs OK Shear.....Allowable 75.00 psi 75.00 psi <br /> Vertical component of active lateral soil pressure IS Other Acceptable Sizes&,Spacings:: <br /> considered in the calculation of soil bearing pressures. Toe:#4 @ 18.00 in -or- Not req'd: Mu<phi*5*lambda*sgrt(f'c)*Sm <br /> Heel:#4 @ 18.00 in -or- Not req'd:Mu<phi*5*lambda*sgrt(f'c)*Sm <br /> Load Factors Key: No key defined -or- No key defined -� <br /> Building Code IBC 2012,ACI <br /> Dead Load 1.200 <br /> Live Load 1.600 <br /> Earth, H 1.600 <br /> a' <br /> Wind,W 1.000 <br /> Seismic, E 1.000 <br />