Laserfiche WebLink
Small Sunline (3-6 Ton Page:3 <br /> 0"YORK Package) N543 <br /> Single Package R-410A Heat Pump <br /> Project Name: NORCO MEDICAL-3 TON-460 VOLT Unit Model#: XN036C00B4C1AAA1A1 <br /> Quantity: 1 Tag#:5 WKS-FACTORY System: XN036C00B4C1AAA1A1 <br /> BLD <br /> Cooling Performance <br /> Total gross capacity 39.0 MBH <br /> Sensible gross capacity 28.5 MBH <br /> Total net capacity 37.1 MBH <br /> Sensible net capacity 26.6 MBH <br /> Seasonal Efficiency(at ARI) 14.00 SEER <br /> Efficiency(at ARI) 12.00 EER <br /> Ambient DB temp. 95.0 °F <br /> Entering DB temp. 80.0 °F <br /> Entering WB temp. 67.0 °F <br /> Leaving DB temp. 58.0 °F <br /> Leaving WB temp. 56.6 °F <br /> Power input(w/o blower) 2.80 kW <br /> Sound power 76 dB(A) ` <br /> Refrigerant <br /> Refrigerant type R-41 OA ' <br /> Heat Pump Performance <br /> Ambient DB temp. 47 °F 3 Ton <br /> HSPF 8 • York Units are Manufactured at an ISO 9001 Registered Facility and Each <br /> Capacity @ 47°F 36.00 MBH <br /> COP @ 17°F 2.20 Rooftop is Completely Computer-Run Tested Prior to Shipment. <br /> COP @ 47°F 3.35 Unit Features <br /> Capacity @ 17°F 19.00 MBH <br /> Heating Performance • Single Stage Cooling <br /> • Single Stage Cooling <br /> Entering DB temp. 60 °F • No Factory Installed Electric Heat <br /> Heating output capacity(Max) 34.5 MBH . Unit Cabinet Constructed of Powder Painted Steel,Certified At 1000 Hours <br /> Nominal electric heat 10 kW <br /> Applied electric heat 10.1 kW Salt Spray Test(ASTM B-117 Standards) <br /> Installed Field • Either Supply and/or Return can be Field Converted from Vertical to <br /> Supply air 1200 CFM Horizontal Configuration without Cutting Panels. <br /> Leaving DB temp. 86.6 °F • Full Perimeter Base Rails with Built in Rigging Capabilities <br /> Air temp.rise 26.6 °F • Scroll Compressor <br /> Stages 1 . Dry Bulb Economizer and Hood(No Barometric Relief Damper)with <br /> Supply Air Blower Performance Economizer Fault Detection&Diagnostic(Meets ASHRAE 90.1-2013,IECC <br /> Supply air 1200 CFM 2015,California Title 24,AMCA 511) <br /> Ext.static pressure 0.6 IWG • 1.5 HP Standard Static Belt Drive Blower <br /> Addl.Unit Losses(Options/Accessories) 0.13 IWG p <br /> Blower speed 945 RPM Replacement Filters:2-(15"x 20"x 1"or 2")and 1 -(14"x 25"x 1"or 2"). <br /> Duct location Bottom Unit accepts 1"or 2"wide filters. <br /> Motor rating 1.50 HP • Unit Ships with V Throwaway Filters with a Standard Filter Rack That Will <br /> Actual required BHP 0.61 HP Accept up to 2"Filters <br /> Power input 0.57 kW . Solid Core Liquid Line Filter Driers <br /> Elevation 0 ft. . Single Point Power Connection <br /> Drive type BELT <br /> Electrical Data • Through-the-Curb and Through-The-Base Utility Connections <br /> • Short Circuit Current:5kA RMS Symmetrical <br /> Power supply 460-3-60 . Copper Tube/Aluminum Fin Condenser Coil,Copper Tube/Aluminum Fin <br /> Unit min circuit ampacity 25 Amps <br /> Unit max over-current protection 25 Amps Evaporator Coil <br /> Dimensions&Weight - Galvanized Steel Drain Pan <br /> Hgt 33 in. Len 83 in. Wth 45 in. Standard Access Doors <br /> Weight with factory installed options 635 lbs. BAS Controller <br /> Clearances • Simplicity SE Controller including Discharge Air,Return Air,and Outdoor Air <br /> Right 24 in. Front 24 in. Back 36 in. Temperature Sensors <br /> Top 72 in. Bottom 0 in. Left 36 in. Standard Unit Controller: Simplicity Control Board <br /> Note: Please refer to the tech guide for listed maximum static pressures An Integrated Low-Ambient Control,Anti-Short Cycle Protection,Lead-Lag, <br /> AME® <br /> Fan On and Fan off Delays,Low Voltage Protection,On-Board Diagnostic <br /> ,,,,, l S�� �� and Fault Code Display.Allows all units to operate in the cooling mode down <br /> ® ,QUALITY �!® ! to 0°F outdoor ambient without additional components or intervention. <br /> • Safety Monitoring-Monitors the High and Low-Pressure Switches,the <br /> Freezestats,the Gas Valve,if Applicable,and the Temperature Limit Switch <br /> on Gas and Electric Heat Units.The Unit Control Board will Alarm on Ignition <br /> Failures,Safety Lockouts and Repeated Limit Switch Trips. <br /> Warranty <br /> • One(1)Year Limited Warranty on the Complete Unit <br /> • Five(5)Year Warranty-Compressors and Electric Heater Elements <br /> Unitary Sales Tool 0.5.9.0 Information is subject to change without notice.Check local codes. Printed 10/13/2016 <br />