Washington State Energy Code:Component Performance Worksheet,Type R-3 Occupancies <br /> Irving Residence <br /> 5817 Lowell Road <br /> Everett,WA 98203 <br /> Heating System Size <br /> Ducts are located in unconditioned spaced <br /> Conditioned Floor Area 288 Equipment size over design load 100°x° j <br /> Conditioned Building Volume _ 2520 Btu/hour outputl 8,912 <br /> Weather Station Everett IC KW 2.6 <br /> Component Performance,R-3 occupancies Code Target Values Proposed Design Values <br /> Area UA Area UA <br /> Vertical Glazing U= 0.300 43 13.0 57 32.9 <br /> Overhead Glazing U = 0.500 0 0.0 0 0.0 <br /> Doors U = 0200 0 0.0 0 0.0 <br /> Flat/Vaulted Ceilings U= 0.027 288 7.8 288 14.2 <br /> Wall(above grade) U = 0.056 355 19.91 341 33.1 <br /> Floors U= 0.029 0 0.0 0 0.0 <br /> Slab on Grade F = 0.360 48 17.3 48 35.0 <br /> Below Grade <br /> 2'depth,wall U = 0.042 0 0.0 0 0.0 <br /> 2'depth, slab F= 0.590 0 0.0 0 0.0 <br /> 3.5'depth,wall U= 0.041 0 0.0 0 0.0 <br /> 3.5'depth, slab F= 0.640 0 0.0 0 0.0 <br /> 7'depth,wall U= 0.037 01 0.01 01 0.0 <br /> 7'depth,slab F= 0.570 01 0.01 01 0.0 <br /> Target UA Total 57.9 Proposed UA Total 115.3 <br /> Target Credits from Chpt. 9 1.0 Proposed Credits from Chpt.9 1.0 <br /> If the Proposed UA s the Target UA, and the Proposed Credits From Chpt 9 are> 1 than the home meets the 2009 WSEC. <br /> Check other code requirements <br /> Copyright 2010,WSUEEP10-009(Version 10)Copied by permission from Washington State University Extension Energy Program. (see copyright restrictions) <br /> 6/5/201'2 <br />