Page 2 of 6 July 5, 2016 <br /> PA T2160619 Asbesto-Test,Inc. 425-489-4040 <br /> 7102 A.K.A. 7030 Lower Ridge Rd.,Everett, WA 98203 <br /> ELECTRICAL SYSTEM: The electrical wiring insulation on the knob and tube wiring was <br /> sampled. The other type(s) of electrical wiring insulation did not appear to be the kind to be <br /> ACM. The power may have been"on"at the time of the inspection,thus sampling was not safe. <br /> Any suspect electrical wiring insulation or any suspect TSI(Thermal System Insulation)found <br /> in, around, or behind any located fuse or breaker boxes should be considered to be ACM <br /> (Asbestos Containing Material), unless determined otherwise by laboratory analysis. <br /> HEATING AND VENTILATION SYSTEM: Heating throughout is wall electric. There was <br /> no visible suspect ACM located associated with any of the electric heating units. It was not <br /> possible to dismantle the electric heating units to locate and/or evaluate any additional suspect <br /> ACM which may be concealed, inside the units, or associated in hidden areas. It is our opinion <br /> any further handling of the heating units should be coordinated by the project manager and/or <br /> abatement contractor. If any additional relating suspect ACM is located prior to and/or during <br /> any demolition or renovation, those materials are PACM (Presumed Asbestos Containing <br /> Material),unless determined to be otherwise by laboratory analysis. <br /> • The fireplace brick and mortar materials were sampled. The fire brick was also sampled. <br /> MISC.: None. <br /> ADDITIONAL STRUCTURES ON SITE INCLUDED IN SURVEY: There is wood <br /> frame garage and shed on the property. The window glazing on the wooden windows was <br /> sampled. The siding vapor barrier materials were sampled. The composition roofing materials <br /> were also sampled. <br /> #of structures included in survey: one house, one garage and one shed. <br /> Requested by: Juliette with Acme Homes <br /> Mo W-d--$1.315 7 <br /> 1� WAS6119 _n <br /> IR2]@5.5313 �� <br /> TMs cert5lim.rAa. ,��-« <br /> Christopher L Patterson <br /> i.,1.10.1.41 crnnpietcd <br /> 4 iulux of Mralfwi ux6iiny axan <br /> Ashestal Wtding InSitCm, <br /> <rnpise,.a(d,TSCA T&.1:149 CIR 769(AHCRA) <br /> I yy f�r <br /> fl-0—Mfi 1211:6 <br /> fr3APmbmt 1.¢-0E85 6q'ti+c:M?y.�&Hit] <br /> Christopher Patterson <br /> Inspector, certified A.H.E.R.A. <br /> Accred.#157289 EXP.May 18,2017 <br /> continue to page 3 <br /> A-r <br /> 1429 Ave.D.#187,Snohomish. WA 98290 <br /> 425-489-4040.-f 775-665-0420 <br />