Laserfiche WebLink
� • � • . <br /> 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and al1 R1 Revised Jan 2014 <br /> Praject Info Project Address peoples BanK-Evertt Branch Date 5/21/2013 <br /> Complfance 2702 Colby Avenue �or Building Departmerrt Use <br /> forms do not <br /> require a Everett,WA 98210 <br /> password Lo ,qRP�icant Name: AWA Electrical Consultants,lna. .-- <br /> us¢. <br /> fnstructionaland Applicant Address: �g075 36th Ave West,Suite E,Lynnwood WA 98036 ��l�G� � �/� <br /> calculating cells <br /> are wr7te- Applicant Phone; (425)775-1799 <br /> Project Description ❑ New Building ❑ Addltlon 0 Alteration ❑Plalls Induded <br /> Lighting Cornpliance Pafh 0 Lighting Power Density Calculations Q Total Building Performance <br /> (!f Total Building Performance then only LGT-CHK!s requlred.) <br /> Lighting Power Allorwance Q gulldfng Area Method � Space-By-Space Method <br /> Method selection requ;red to <br /> ena6le LPA forrns <br /> Interior Lighting Sysfern <br /> Description <br /> Briefly describe lighting <br /> system type and feafu�s. <br /> Additions and Change af Space Use (C101.4.3 &C101.4.4) <br /> ❑ Addition area or Change of Space Use area camplies with all appl(cable provisions as stand alone project <br /> � Addition ares is combined with existing building lighting sysiems to demons#rate compliance with all applicable <br /> provisions per C101.4,3 <br /> Provlde BuiJding Ana Method(LTG-lNT-BLDJ or Space-By-Space Method(LTG-INT-SPACE)Compliance Farm. Document maximum <br /> a!lowed and proposed{including exlsting if applicable)Iighting wattage oi Addition or Change of Use space.Provids applicable Jighting <br /> contro/s per C4D5.2 and commissloning of lightrng contrals per C405.93. <br /> Alferations, Renovations and Repairs (C101.4.3.1) <br /> ❑ 60%or more of luminaires in space replaced <br /> Provide Building Area Method(LTG-lIVT-BLD)or Space-By-Space Method(LTG-lNT-SPACE}Compliance Form.Document maximum <br /> a!lowed wsttage tvithin the IlghUng relrofit space in Maximum Allowed Watfage table and proposed(including exfsfJng}lighting waftage ln <br /> Proposed Wa(fage table. Retrofrt and non-retrofit spaces shal!be documented separately using muliiple forms. <br /> �] Less than 60°k of luminaires in space replaced <br /> Provide a separate Space-By-Space Method(LTG-INT-SPACE)Comp/iance Form for this refrofrt area.Document existing tota!wattage <br /> wfthln the lighting retrofit space in cell provlded in fhe Maximum Allowed Wattage table.Document proposed{including exlsting)lighting <br /> wattage in the Proposed Wattage table. <br /> � Lamp ancilor ballast replacement within existing fuminaires only—existing total Interiar building wattage not increased <br /> (� New wiring Insialled to serve added fixtures and/or fixtures relocated to new circult <br /> Provtde appticable manual lighting controls(C405.2.1),occupancy sensors(C405.2.2.2),daylight zone controls(C405.2.2.3),specific <br /> applicaYion controls(C405.2.3),and commissioning of lrghting controls per C905.43 <br /> � New or moved lighting panel <br /> Provide a!!applicable lighfing controls as noted for New Wiring,automatic time switch controls(C4�5.2.2.1),and commissioning of Jighting <br /> controls per C405.13. <br /> � Space Is reconfigured-luminaires unchanged or moved only <br /> Provlde al!applicable Jrghting controls as noted for New Wiring and commissioning oflighting controls per C4Q5.?3. <br /> [� No changes are being made to the interior lighting and space use nof changed. <br /> �� � <br /> � <br /> �: <br />