Laserfiche WebLink
GENERAL NOTES O STAIRWAYS PER IRC R311.7 �W� � <br /> FOR NINDOWS NI1H OPEF2P&E OPENINGS AIORE � 36�AIIN.STAIRWAY VAD7H.LAPAINGS SHALL <br /> 1HAN 72"ABObE 1HE FlNI9im GRAOE Oft HA�E A 36"MINIAIUN DIAIFNSION IN THE <br /> SUf�ACE BElOW,iHE LONEST PPRT OF THE aRECTION OF 7RA�EL.A LANDING IS NOT Z a� o� <br /> CLEAR OPENING SHA11 BE 24"IAINIAIUM ABOVE REQUIRm VMERE THFRE IS A D00(t AT 7HE ' <br /> 1HE FLOOR.EXCEPIIONS: FIA.LY OPEN HINDOWS TOP OF AN M7FAOR FlJGHT OF STAIRS. a�a MM <br /> YMERE A 4'SPFiERE MAY NOT PASS iHRWGFI INCLUDING STAIRS IN AN ENCLOSED GARAGE, �o� <br /> OR YMERE FP11 PRE`�ENTION DENCES ARE PRONDm 7HE DOOR DOES NOT SN1NG 04IIi z�• pa <br /> PROHDm PER AS711 F 2090 OR R6123. 7HE STAIRS.PoSFRS TO BE 7�'4 MNONUM o Na <br /> � unrwr pND TREPDS TO 8E 10'AIMIMUM ���'j <br /> PRONDE SAFETY GLASS PER IRC R30H. DEP7H,BO7H VA1N A MAl4MUlA VARIATION OF m z� <br /> 53'-0" <br /> 3E�.TREADS N1TH$OUD PoSFRS TO HAVE�� a}�� n <br /> g�yUp{TS Tp pE pp�gLE ppNp.,g{q� MINIMUAI TO 1Y�MAX NOSING OR 11�NINIAIUAI W � �N <br /> 8�_�• 4�_Q• RE95TPNT APPF20�£D PoqD PLASTIC,LANINAlEO DEP1H.4�SPFfERE NAY NOT PASS 7HRWGN �a� �'om, <br /> SAFETY GUSS,FULLY lE1,IPERED qASS. OPEN R1SER5 ON STAIRWAYS PoSING NORE =w� o a <br /> ' 23'-0' ZZ�-0' HEAT-S7RENG1HfNm qASS,OR NIRFD GLASS. THAN 30'.HANDRAIL REWIRED IF 4 IX2 AIORE o'^ `^3 <br /> PRONDE 4'NINIAIUlA CURB(OR SElF FlASHING PoSERS TO BE INSTALLm BEfNfEN 34�-38' W s� �G <br /> � 13'-0' 10'-0" ¢ <br /> ASSEl.IBIY Nlhi 3:12 MINIMUAI PoTCH OR PER ABO�'E N09NG AND HA�E A 1Y�-2�0 GPoP �o a �� <br /> NPNUFACNRER INS7RUC710NS). CONTINUOUS FIXt THE NLL lENC7H OF THE �U m ^� <br /> 3'-3' 4'-6' 2�-6' 2'-11� v w <br /> FLICHL RENRN ENDS TO WALL OR IENEl. <br /> HOSE BIBBS TO BE BACKROW PREVENTION AND INSTAl1 2x10 BLOG(ING BET`AEQi SNDS TO <br /> F'R�RESSTANT TYPE. SUPPORT HANDRAIL BRACKETS.FlREBLOqC <br /> 6x3 MIN. IANDING 3x3 MIN. BETv�EEN S1UDS AT STRINGFR.6'-8'MINIAIUAI <br /> 16'-0' <br /> 60 12 ABV 4� 1z ABV � �NDING � aii H novMc �p�� puq{p(tC g SH ARW I(�I �7tPCn�tiEnD CLEPRANCE.at07ECi � <br /> 6o SL DR SAF GL p g � 7� MAX � NAAJNG MUST BE INSPECIED BEFORE CO�ERING. ENCLOSEO ACCES5BLE UNDQt STAIR WAllS <br /> 7�' MA�( STEP 4x10 2DF I S�P I TRIPLE pND C�LING NITH J��GWB.A FlJGHT OF G <br /> _ ______ S1lJ0S STAIRS SHALL NOT HA�E A VERIICAL PoSE Q � <br /> — - -_ --� — --- ---_'_=�-_ <br /> ..-_--- - . _- -- — LAR(�.fi 1HAN 12 FEET BETHEQI FLOOR <br /> 4x10��2DF � �---t._ . , , •. Z8� OPT. DOOR LEVELS IXt LANDINGS. � <br /> � m� OO j D.W. � i I `�>' 4x6 #2DF BATHROOAI NOTES 0 <br /> r I O FlREBlOC7C NBS AND 9i0WER5 PQi R30211. �i� <br /> C,i w� I 30�x30'MINIlAJIA CLEM�ACE IN SHONfR.22� <br /> II O <br /> 7n I ApNIIAUM WIOTH SHONER DOOR TO OPEN OU7WARD <br /> ,� o� i �F HINGED.30"MIOE X 24�DEEP CLEAR SPACE <br /> o t� � cn REWIRFD W151DE SHONER DOOR.fNQOSURE$ <br /> o mo N � D I N I N G R M a� �oo cF-ti+ H000 'o TO BE SPFETY qASS NONABSIXiBFNT SURFACE <br /> Q X � � �i VENT TO EXT. <br /> uP s'x+m s�+o�rs.use c�o+r eoum oR <br /> �i �� �p o • I o CAIENT FIBER BOARD FOR 111E BAIXMG.VMOR <br /> � N N c°I II i BARPoER NOT PERMITfED BQ1ND WP.GM8 AT <br /> • � K I TCH EN G A R AGE � E�.W�,-2.5����ow�5,���. <br /> �, �2• �•_o- � F NB OR SHONfFi CONIROL VAL�fS TO BE � <br /> 4" CONC SLAB pREg$URE BALANCE OR THERMOSTAIIC MIXING c� <br /> �c, I I (2)2x6 SLOPE 1/8":1' T1PE 1.6 GAL PFR FLUSH AINa1JUlI TqLETS.15' � � <br /> rn /{2HF 0.EAR SPACE RE0.11RED.EACH SIDE FRON t OF <br /> �--� -- ----- I�: 0 TOIIFf&21'CLE?R SPACE REWIRED N FRONT, m o <br /> � I I � 6x10�2DF "�B� 28 Q INSTAIL ZxtO BLOCXING FOR TONEL BARS UP l8' � N <br /> I I N STUDS 13'-0� 1��-�� g w ABO�E FLOOR OR B0.0W 9lL HQQiT IF AT o w <br /> L- � � 5'-1�� 4�-2' �� I XINDOW.NSTN1�.00I4NG FOR TP.Hq.OERS � <br /> o INA1LAlE IXTFRIOR WP11S ADJACIIIT TO <br /> F YER REFRIG � �„ �„ I � 910MERS AND 11�5 P1A INSTALL P1R BPRRER <br /> I '' a � � � SPACE \% S�g x 22�Z 24F-V4 GLB � SFPAFtAiwG THEu FRpI 1HE 910NERS AND <br /> �i � 3� �� � -�;, m� _ _,(4)STUDS � 7"-0" MIN. CLEARANCE 4x6 #2DF;I �i NBS <br /> 3�8 x i 3�2 24F-v4 GLB o v, _ - COLUMN GARAGE APPUANCES <br /> DBL � BR'G WALL I O P�LO7S,BUR#RS,SNITCNES UP 18'NiN�IUM <br /> � � STUDS s �� �� � � neo�E Roaa.u.l.aPPRo�n nPPur�cFs wn1 <br /> � � W I I� I � U �' AUTO SFAITOFF SN7TCH.INSTALL @,PACT Bq1MU. <br /> v � •� � 2g �I I I W I o �j DUC1S IN GARAGE TO 8E 26 GAUC£S1EEL(NO <br /> O I�I IN I N OPENINGS).NSTPLL WATER HEAIER ON A <br /> x � io GALVPNIffD STFFEL PAN NIIH DRA1N TO IXIERIOft <br /> I T <br /> <p --- �O wI> � I XfffRE IEAK WOUID CAUSE DAYAG£.SET <br /> NU I � Z �?� � i `� El£C1PoC WA1FR F�ATER ON R-10 INSUUIID <br /> e- 2 n w . . � � ��I�:. � � <br /> � N a N • �,y� a � � o INCpAPRES9ElE BASE B�STALL SEI9IIC S7RAPS <br /> r- � � 3� LI VI N G R M M �� 2 6 2 F CL G BR�� �` -�o,�� N MI7HIN TCP Y�AND BOTfOfA�(4'lAMIlAUA1 ABO�£ <br /> Z p CON7RqS).PRONDE PRESSIRE�lJt�TO <br /> o � � N a Q �a J TS � 1 .C. WALL ,� x�v � rn� EXTQ210R.IF FUFL FlRED APPIJAN�S D(CfID <br /> •� � � •i N V cv Z -- -- - -- -° � H� J ��I- � 1000 B7U/H INPUT PER 50 CU.FT.OF GARA(E <br /> �- � Na •.,3 0 -x� OPEN RAIL I � O o � � NQ `�l�IE INSTPII 2 SptEENm COu8US710N Nti <br /> � � I . n�� �� 2 Q �I �� m �u� !m� `hNTS iHRWGH EXIERIOR WPl-L,ONE`M1HP!12' <br /> � o� 12" SHELF ON � � O > � N� � pF�c�a�w�niw i2'OF rtOIXi.usE <br /> N � � a YZWALL CAPPED ;:, � OPEN TO�I 24 � , 7RIPLE �p v� ac�� NON-CLOSE-PBIE LOU�ffiED 12x12 WALL�ENTS <br /> � - C� �_ <br /> � c�U x o � ABOVE i� �=---�U =_ _i. i - - - �--�--- n <br /> i �_ � � 42" A.F.F. � � � ', STUOS S�a x 16�2 24F-V4 GLB � �-� OR Sx18 FOUNDAnON T1PE`h?ITS W wA11 FOR A <br /> G `~a a •� 3� �2cx� P�R IANIAIUTA NET FREE PREA OF 1 5a.Pl PER 4�000 <br /> N N � ABV�= ��(� 16�X H� O.H. GAR. OR. �o . BN/ti EnCH�NT. <br /> �I � o � v� �5o � Q{ � r � O GARAGE RRE SEPARATION <br /> � o �i w� ,�, o �/I �� OBL �__ INSUL & SOf�FiT 4 ppQ11NGS FROfA GPf2AGE INiO StEEPING ROOAI <br /> �� -------------- '"' <br /> z o?� 2 2x6 2HF CONT. �r 3 2 2X 2HF` Ji ��JDS LINE OF UPPER CANT. N�O�To��i�D�'BEfNFF111�G TM�AND� �o� <br /> co � - - � - - _--- - <br /> ��¢ S�SH 265�SH 265°SH �0 7, Nnx S 2636SH `• w000 aR sEEI�xrn Souo at HowerCa�B <br /> rn� 3' � CCRE,OR 20�IINUTE FlRE RATED EWIPPm NITH <br /> •i I X� 12ABV 2fi12ABV 2612ABV Z� e' 3'-3' 1'-7' 2812ABV o Z'-�o1f' 0 16'-3' 7-1oJ4' <br /> � �Yc� 2'-6' 2'-6" 2'-6' 3" v� I- A SElF-CL09NG DE�1C£DUCTS IN GARAGE h <br /> . � N 4'-2' S�-10' .� ' " WCTS PENETRAiING 1HE WALLS OR CFJUNGS <br /> i a "?� INSUL & � 'N SEPARA7ING 7HE DNEILING fRON hIE GPRAGE <br /> � �- � --� 3� SOFFIT r-- COVERED PORCH r--� 4ip1.L 8E N0.26 GAGE SFiEET SiFFE1 AHD HA�E z <br /> o I I _ I 6x10 #2DF _ I I � I NO OPFNINGS MTO THE GPRAGE.FlLL ARIXJNO �/ �o <br /> I I I I 6x10 #2DF I I ,n O7HEFi PFNEfRA710NS 4ATH APPf20�ID MATERIAL N i <br /> L -J - ' -J _- L-- L_ J SEPAFtA T E hiE GAFiACE FROA1 THE RESIDENCE C� �_ <br /> DN TO GRADE OPEN RAIL UP 36" ON TO GRADE AND ITS ATfIC AREA YA7H Y�'Gri8 INSTAl1E�ON �na <br /> SIMPSON ECCL THE GARAGE 90E SEPARATE FRON HABITABLE x 3 <br /> ABV FIN. PORCH I f'� c� <br /> TO BEAMS TH�SEpA Al1CN S A��ppR-X�CNB,CANO YMERE � � w <br /> &x6 COIUlAN SIMPSON LJNE OF UPPER ASSEAIBIY,hiE SUPPIX211NG S1RUC7URE SHALL � �� <br /> COIUTAN CPP TO B!A(S). BE PROTECTT011 N1TN Yt�GN& � v~i a w <br /> BUILT UP TAPQtm LEVEL (L.U.L.) <br /> COLUMN g PEDESTAL i � p <br /> T�PICAL 6 LOCATIONS i 3 a'� <br /> �r r-o• �r ���-o• �a'-a' 12' ELECTRICAL LEGEND z ~N� <br /> 2'-0" 9'-0' 2'-0' 8'-0" 2�-0' . �Z <br /> 511q(E PLNilA PQ2 R374 AS AIENDED&IJSTED PER Q �.� <br /> 13'-0� 10'-0� 6'-0" 16'-0" O UL 217.INSTALL PER HIXIg}IIOLD WARNINC J <br /> } �� <br /> 23'-0' 22'-0" W54i0L0 ClR2RENT NI7H BAIlQi BAqN�.110V � <br /> �N <br /> �W <br /> IN7ERCONf�ffCT EAOi BFDROOY AND LEVEl. o� <br /> 8'-0' %5._Q c� <br /> CPFiBON MONObDE ALARAI PER R315 AS AIAENUFD. <br /> 53'-a� C0 INSTPLL IX1i90E OF EACN SEPPRATE SlffPiNC AREA <br /> IN THE UNEDIAIE NqNITY OF TF#BEDROOII. <br /> MA I N F L 0 0 R P L A N SCALE: 1/4• - ,�-a• � � 50 CF1 IA�N.E�iAUST FPN-I�ETIT TO IXIEftlOR. <br /> 667 S�. FT. MAIN FLOOR 2 <br /> 1206 SQ. FT. UPPER FLOOR <br /> 1873 S0. FT. TOTAL LIVING �� <br /> 572 SQ. FT. GARAGE � <br />