My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2431 RUCKER AVE MASONIC TEMPLE 2019-05-07
>
Address Records
>
RUCKER AVE
>
2431
>
MASONIC TEMPLE
>
2431 RUCKER AVE MASONIC TEMPLE 2019-05-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2019 3:30:15 PM
Creation date
6/29/2017 11:16:15 AM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
2431
Tenant Name
MASONIC TEMPLE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
81
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PUBLOC L�YO/�/�C.� <br /> September 30, 2015 <br /> Alici Anderson <br /> brooksideplum@yahoo.com <br /> RE: Owner: Valley of Everett Scottish Rit. <br /> Job Address: 2431 Rucker Ave <br /> Plan Check No: M1509-033 <br /> Dear Applicant, <br /> In response to your application for a Type 1 Hood, your plans have been examined and you are <br /> advised that revisions may be necessary before a permit can be issued. Please review and <br /> respond to the comments below. These comments address building issues only. Additional <br /> revisions, or additions, may be required by other departments (such as Utilities, Planning or <br /> Fire). All references refer to the 2012 International Building Code (IBC), the 2012 International <br /> Fire Code (IFC), the 2012 International Mechanical Code (IMC), and the Z012 International <br /> Energy Conservation (IECC), as amended by the State of Washington and adopted by the City <br /> of Everett. The current IBC referenced standard for accessible design is the 2009 "Accessible <br /> and Usable Buildings and Facilities" (ICC/ANSI A117.1). Federal ADA regulations and standards <br /> may be more restrictive. <br /> In order for the processing of your application to continue, it will be necessary to provide the <br /> Building Division with two complete new sets of construction documents reflecting the <br /> corrections requested. <br /> 1. Please provide floor and roof plans to show where the equipment is proposed. <br /> Please indicate what kind of appliances the hood will be venting. Please provide <br /> the dimensional relationships between the cooking equipment and the hood. <br /> Please provide the location of the proposed exhaust fan and an IMC required <br /> makeup air fan on the roof. Exhaust and makeup intake must have a minimum <br /> 10 ft. separation. Exhaust must be at least 10 ft. from property lines. <br /> 2. The submitted design states ��It is the responsibility of the architect/ owner to <br /> ensure that the hood clearance from limited-combustible and combustible <br /> materials is in compliance with the local code requirements." The local code <br /> requirements are from the 2012 IMC. Please provide the ensurance by means of <br /> a detailed cross section and/or verification from the manufacturer. <br /> If you have any questions, please call me at 425-257-7264. <br /> Please prepare a response letter showing where each item in this correction letter is addressed <br /> on the plan set. <br /> Upon resubmittal of the drawings, your application will be given priority and plan review will <br /> recommence. <br /> All required submittals shall be of sufficient detail and contain sufficient information to ensure <br /> that the proposed structure will be constructed in compliance with all adopted codes. <br /> Sincerely, _��_ <br /> Steve Miller � <br /> Associate Engineer <br /> CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 • (425) 257-8800 • Fax (425) 257-8882 <br /> S`J('oinmunA('lericnlASbllller�2431 Rucker Ave(M I 509-033)doc <br />
The URL can be used to link to this page
Your browser does not support the video tag.