PUBLOC L�YO/�/�C.� <br /> September 30, 2015 <br /> Alici Anderson <br /> brooksideplum@yahoo.com <br /> RE: Owner: Valley of Everett Scottish Rit. <br /> Job Address: 2431 Rucker Ave <br /> Plan Check No: M1509-033 <br /> Dear Applicant, <br /> In response to your application for a Type 1 Hood, your plans have been examined and you are <br /> advised that revisions may be necessary before a permit can be issued. Please review and <br /> respond to the comments below. These comments address building issues only. Additional <br /> revisions, or additions, may be required by other departments (such as Utilities, Planning or <br /> Fire). All references refer to the 2012 International Building Code (IBC), the 2012 International <br /> Fire Code (IFC), the 2012 International Mechanical Code (IMC), and the Z012 International <br /> Energy Conservation (IECC), as amended by the State of Washington and adopted by the City <br /> of Everett. The current IBC referenced standard for accessible design is the 2009 "Accessible <br /> and Usable Buildings and Facilities" (ICC/ANSI A117.1). Federal ADA regulations and standards <br /> may be more restrictive. <br /> In order for the processing of your application to continue, it will be necessary to provide the <br /> Building Division with two complete new sets of construction documents reflecting the <br /> corrections requested. <br /> 1. Please provide floor and roof plans to show where the equipment is proposed. <br /> Please indicate what kind of appliances the hood will be venting. Please provide <br /> the dimensional relationships between the cooking equipment and the hood. <br /> Please provide the location of the proposed exhaust fan and an IMC required <br /> makeup air fan on the roof. Exhaust and makeup intake must have a minimum <br /> 10 ft. separation. Exhaust must be at least 10 ft. from property lines. <br /> 2. The submitted design states ��It is the responsibility of the architect/ owner to <br /> ensure that the hood clearance from limited-combustible and combustible <br /> materials is in compliance with the local code requirements." The local code <br /> requirements are from the 2012 IMC. Please provide the ensurance by means of <br /> a detailed cross section and/or verification from the manufacturer. <br /> If you have any questions, please call me at 425-257-7264. <br /> Please prepare a response letter showing where each item in this correction letter is addressed <br /> on the plan set. <br /> Upon resubmittal of the drawings, your application will be given priority and plan review will <br /> recommence. <br /> All required submittals shall be of sufficient detail and contain sufficient information to ensure <br /> that the proposed structure will be constructed in compliance with all adopted codes. <br /> Sincerely, _��_ <br /> Steve Miller � <br /> Associate Engineer <br /> CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 • (425) 257-8800 • Fax (425) 257-8882 <br /> S`J('oinmunA('lericnlASbllller�2431 Rucker Ave(M I 509-033)doc <br />