My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3102 RUCKER AVE 2017-07-10
>
Address Records
>
RUCKER AVE
>
3102
>
3102 RUCKER AVE 2017-07-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/10/2017 9:35:38 AM
Creation date
6/29/2017 11:55:25 AM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
3102
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' ` GENERAL <br /> THE CONTRACTOR IS RESPONSIBLE FOR VERIFICATION AND CORRELATION OF ALL ITEMS AND WORK NECESSARY <br /> FOR COMPLETION OF THE PROJECT AS INDICATED BY THE CONTRACT DOCUMENTS. SHOULD ANY QUESTION ARISE <br /> REGARDING THE CONTRACT DOCUMENTS OR SITE CONDITIONS, THE CONTRACTOR SHALL REQUEST <br /> INTERPRETATION AND CLARIFICATION FROM THE ENGINEER BEFORE BEGINNING THE PROJECT. THE ABSENCE OF <br /> SUCH REQUEST SHALL SIGNIFY THAT THE CONTRACTOR HAS REVIEWED AND FAMILIARIZED HIMSELF WITH ALL <br /> ASPECTS OF THE PROJECT AND HAS COMPLETE COMPREHENSION THEREOF. THE CONTRACTOR SHALL BE <br /> RESPONSIBLE FOR CONFORMANCE TO ALL SAFETY REGULATIONS DURING CONSTRUCTION. <br /> THE CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE. UNLESS OTHERWISE <br /> SPECIFICALLY NOTED, THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION OR CONSTRUCTION LOADS. ONLY <br /> THE CONTRACTOR SHALL PROVIDE ALL METHODS, DIRECTION AND RELATED EQUIPMENT NECESSARY TO PROTECT <br /> THE STRUCTURE, WORKMEN AND OTHER PERSONS AND PROPERTY DURING CONSTRUCTION. THE CONTRACTOR <br /> SHALL, AT HIS OWN EXPENSE, ENGAGE PROPERLY QUALIFIED PERSONS TO DETERMINE WHERE AND HOW <br /> TEMPORARY PRECAUTIONARY MEASURES SHALL BE USED AND INSPECT SAME IN THE FIELD. ANY MATERIAL NOT AS <br /> SPECIFIED OR IMPROPER MATERIAL INSTALLATION OR WORKMANSHIP SHALL BE REMOVED AND REPLACED WITH <br /> SPECIFIED MATERIAL IN A WORKMANLIKE MANNER AT THE CONTRACTOR'S EXPENSE. <br /> THESE PLANS, SPECIFICATIONS, ENGINEERING AND DESIGN WORK ARE INTENDED SOLELY FOR THE PROJECT <br /> SPECIFIED HEREIN. MILLER CONSULTING ENGINEERS DISCLAIMS ALL LIABILITY IF THESE PLANS AND <br /> SPECIFICATIONS OR THE DESIGN, ADVICE AND INSTRUCTIONS ATTENDANT THERETO ARE USED ON ANY PROJECT <br /> OR AT ANY LOCATION OTHER THAN THE PROJECT AND LOCATION SPECIFIED HEREIN. OBSERVATION VISITS TO THE <br /> JOB SITE AND SPECIAL INSPECTIONS ARE NOT PART OF THE STRUCTURAL ENGINEER'S RESPONSIBILITY UNLESS <br /> THE CONTRACT DOCUMENTS SPECIFY OTHERWISE. <br /> NON STRUCTURAL PORTIONS OF PROJECT, INCLUDING BUT NOT LIMITED TO PLUMBING, FIRE PROTECTION, LAND <br /> USE, SITE PLANNING, EROSION CONTROL, ELECTRICAL, MECHANICAL, FLASHING AND WATER-PROOFING ARE <br /> BEYOND THE SCOPE OF THESE DRAWINGS AND ARE PROVIDED BY OTHERS. EXISTING STRUCTURAL ELEMENTS ARE <br /> DESIGNED BY OTHERS. <br /> SPECIAL INSPECTION OF WELDS AND POST INSTALLED ANCHORS ARE TO BE PROVIDED BY A SPECIAL INSPECTION <br /> AGENCY AS REQUIRED BY THE BUILDING OFFICIAL FOR ELEMENTS OF THE PROJECT THAT DO NOT MEET THE <br /> APPROVAL OF CONSTRUCTION OF A MINOR NATURE OR AS WARRANTED BY CONDITIONS IN THE JURISDICTION <br /> (SECTION 1704.2, EXCEPTION 1). <br /> CONTRACTOR TO VERIFY ALL CONDITIONS PRIOR TO FABRICATION OR INSTALLATION. ENGINEER OF RECORD FOR <br /> THE PROJECT IS TO BE NOTIFIED IF CONDITIONS DIFFER FROM WHAT IS SHOWN ON THE DRAWINGS. <br /> BUILDING CODE <br /> ALL PHASES OF THE WORK SHALL CONFORM TO THE 2015 INTERNATIONAL BUILDING CODE INCLUDING ALL <br /> REFERENCE STANDARDS, UNLESS NOTED OTHERWISE. <br /> DESIGN LOADS <br /> THE FOLLOWING ARE THE DESIGN REQUIREMENTS: <br /> STRUCTURAL DESIGN CRITERIA <br /> RISK CATEGORY II <br /> WIND DESIGN DATA <br /> BASIC WIND SPEED 3 SEC GUST 110 MPH � R • WqT <br /> EXPOSURE g �� �o��sy� cP� <br /> �' � ��� �'�'o 'G <br /> // � <br /> _/, . V <br /> �� � � �(��1����' <br /> P ,� 39251 0 � <br /> �i<` FG/STER� ��� <br /> �SS�ONAL E�G <br /> 9570 SW Barbur Blvd Project Name Pylon Sign Project# 161075 <br /> Suite One Hundred <br /> � Portland,OR 97219 <br /> _ Location 3102 Rucker Avenue, Everett,Washington <br /> Client Ramsay Signs <br /> M I L L E R phone 503.246.1250 <br /> C 0 N S U LT I N G Fax 503.246.1395 B�S C.� 8/24/16 S2 of 4 <br /> www.miller-se.com BY Ck'd Date Page <br /> ENGINEERS <br />
The URL can be used to link to this page
Your browser does not support the video tag.