Laserfiche WebLink
® 4242 Baldwin Boulevard ARCHITECTURAL SPECS <br /> Corpus Christi,Texas <br /> • I USA 78405-3399 AUTOMATIC SLIDING DOORS <br /> Tel:800-531-3111,361-888-5591 <br /> H rton Fax:800-531-3108,361-888-6510 Profiler®Series 2000 <br /> www.hortondoors.comA6.2 <br /> Sliding Door System with Electric <br /> AUTOMATICS The Automatic Choke Linear Drive Operator Page 2 of 7, Feb 15 <br /> 1.03 SUBMITTALS <br /> A. SHOP DRAWINGS&PRODUCT DATA: Submit drawings and product data showing layout, profiles, product <br /> components including anchorage, accessories, finish and glazing details (where required). <br /> B. CLOSEOUT SUBMITTALS: Submit the following: <br /> 1. Owner's Manual &Warranty document as specified herein. <br /> 2. AAADM inspection compliance form completed and signed by certified AAADM inspector prior to doors being <br /> placed in operation as proof of compliance with ANSI A156.10. <br /> 1.04 QUALITY ASSURANCE AND PERFORMANCE REQUIREMENTS <br /> A. INSTALLERS QUALIFICATIONS: Installer shall be factory trained, certified by AAADM, and experienced to <br /> perform work of this section. <br /> B. MANUFACTURER'S QUALIFICATIONS: Manufacturer to have minimum (5)five years successful experience in <br /> the fabrication of automatic doors of the type required for this project. Manufacturer capable of providing field <br /> service representation during installation, approving acceptable installer and approving application method. <br /> C. CERTIFICATIONS:Automatic sliding door systems and options shall be factory certified to meet performance <br /> design criteria in accordance with the following standards: <br /> 1. ANSI A156.10: For Power Operated Pedestrian Doors; Sliding Doors section. <br /> 2. NFPA 101: Code for Safety to Life from Fire in Buildings&Structures. <br /> 3. ETL Listed:Tested to UL 325 Standard <br /> 4. BOCA: Means of Egress, Power Operated Doors <br /> 5. ICBO/UBC: Egress Through Lobbies <br /> 6. ICC/IBC: Egress Section <br /> D. OPERATING RANGE: -30° F to 130° F(-34° C to 54°C) <br /> E. OPENING FORCE REQUIREMENTS FOR EMERGENCY EGRESS: <br /> 1. Slide-swing panels shall require no more than 50 lbf. (222 N) of force to swing open. Slide-swing panels shall <br /> be capable of swinging out 90°from any position of slide movement. <br /> 2. Slide-swing panels and swing-out sidelites shall have torsion spring designed to re-close panel if pushed <br /> openin the direction of egress. <br /> 3. If power fails, slide panels can be manually slid open with no more than 15 lbf(222 N)of force. <br /> 4. Units are ETL listed as an exit way and are compliant with NFPA 101. <br /> F. CLOSING FORCE REQUIREMENTS: Maximum force required to prevent sliding panel from closing =28 lbf. <br /> (124.5 N)Adjustable Reversing Circuit will reopen door unit if closing path is obstructed. <br /> G. HEADER CAPACITY: Header shall be capable of supporting: <br /> 1. Biparting: Up to 250 lbs. (113.4 kg) per slide panel over spans up to 16'-0"(4877mm)without <br /> intermediate supports. <br /> 2. Single Slid-(3: Up to 350 lbs. (158.7 kg)per slit- -- - - _. -- - •' ," _•-•- •_- . _ .. _ - _ <br /> U129- <br /> ti <br />