My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2000 TOWER ST OLYMPUS HALL 2017-07-28
>
Address Records
>
TOWER ST
>
2000
>
OLYMPUS HALL
>
2000 TOWER ST OLYMPUS HALL 2017-07-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2017 11:48:31 AM
Creation date
7/17/2017 9:40:11 AM
Metadata
Fields
Template:
Address Document
Street Name
TOWER ST
Street Number
2000
Tenant Name
OLYMPUS HALL
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
52
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Permit#: E1606-057 <br /> ELECTRICAL SYMBOLS LEGEND AND ABBREVIATIONS REMC Site Address: 2000 TOWER ST <br /> ' (SOME SYMBOLS M AY NOT BE USED ON DRAWINGS) ELEC' <br /> Owner- EVERETT COMMUNITY COLLEGE <br /> -- - - - 1 PRIOR 70E <br /> DISTRIBUTION LIGHTING FIRE ALARM ABBREVIATIONS BICE ls Tenant: OLYMPUS HALL <br /> >t PAVELBOARD AorAMP AMPERES 2. FIELD VER App.Date: 6/9/2016 <br /> p—y SUP.FACEPENDANT MOUNTED STRIP LUMINAIRE ® FIRE ALARM CONTROL PANEL PANEL SCF <br /> ® <br /> SWITCHBOARD ORMCC(DRAWN TOSCALE) (LENGTH TO SCALE) AC ALTERNATING CURRENT 6. ITISASSUI Proposed Use: COLLEGE <br /> ® FIRE REARM ANNUNCIATOR PANEL SLlPPORTE <br /> �(�()( DESIGNER RESERVED EQUIPMENT ENCLOSURE.DEFINE LETTERS SURFACE OR,FETJQANT AIOUNiED LINEAR LUMINAIRE P/C AIR CONDITIONING EKIy7INGV Description: HVAC UPGRADES,PANELS, FEEDER, <br /> INSIDE OF SYMBOL (TO SCALE 4N VVINGS) ® FIRE B04AL EXPANDER PANEL <br /> AIC AMPERE iNTERRUPTINGCAPACJTY 7. EXISTING LIGHTING-ECC OLYMPUS HALL <br /> QT DRY TYPE TRANSFORMER(DRAWNTOSCALE) SURFACE OR PENDANT MOUNTED LUMINAIRE MANUAL PULLSTATKXN <br /> AL ALUMINUM DUCTSAFT <br /> :® UTILITY METER BASE RECESSED LUMINAIRE(TO SCALE ON DRAWM^.eS RE GAUGE COHORN[SPEAKER]] MATERIALS <br /> ANG AMERICAN WIRE <br /> MAGNETIC MOTOR STARTER HORN[SPEAKER]WITH VISUAL SIGNAL(STROBE) BLDG BUILDING #10TRRYN[ Reviewed By: Date: / <br /> 0 RECESSED DCWI FLIGHT 2 SCHEDULE <br /> ®1 COMBINATION STARTER AND DISCONNECT SWITCHo- VISUAL SIGNAL(STROBE) C CONDUIT BEGINNING I,, <br /> ®� RECESSED WALL WASHER ® HEAT DETECTOR f lce Set .Yob Site Set Fre/Planning Set <br /> S. COCRDINA- <br /> �1 DISCONNECT SWROH C.O. CONOUITONLY OF GONSTF <br /> rM� WALL MOUNTED LINEAR LUMINAIRE © BINDLE DE?ECTOR <br /> EP FUSED DISCONNECT SWITCH C,B CIRCUIT BREAKER 4. IN AREAS 0 <br /> VARIABLE FREQUENCY C <br /> D DllCTSMOKE DETECTOR EXISTINGD <br /> yy WALLSCOJCE RACEWAYS <br /> ®� DRIVE MOTOR CONTROLLER `>-< 9& <br /> MAGNETIC DDDR HOLDER •.OKT CIRCUIT i, NEARESiU <br /> EXIT FLCTURE-UNIVERSALLY MOUNTED CL CF14TER LINE <br /> �1 ENCLOSED CIRCUIT BREAKER CONTINUItt r—VIrtWHa rvrvtxuvwtwtt-rAervr,uevweo.tm (L <br /> ® DOOR CLOSER WITH ELECTRIC HOLD OPEN FIXTURES OUTSIDE OF THE DEMOLITION OR REWORK SCOPE OF `�WT� <br /> j t ENCLOSED CIRCUIT BREAKER WITH SHUNT TRIP OPERATOR � F��tEMERG'ENCY LUMINAIRE W'RH INTEGRAL 90 MIN � FIRESMOKE DAMPER - CLD CEILING I WORK. �LJ <br /> ® SPRIML.ER WATER FLOW ALARM CONNECTION CONS CONCRETE <br /> 5. MAIMAINEXISTWG LIC-FIT FONP.ES.ASSOCJATEO RACEWAYS, '(W U� CM <br /> A - CT CURRENT TRANSFORMER CONDUCTORS AND CONTROLS UNO ON ELECTRICAL DRAWINGS. J W ./I� <br /> RACEWAYS FIXTURE DESIGNATION (j SPRINKLER VALVE TAMPER SWRCHCONNECTJON d EXISTING PANELS ARE SCHEWLIDTO REMAIN, rt Y+ <br /> 13a SUBSCRIPT. A LUMINAIRE TYPE CU COPPEP, lJ (� j O <br /> yam( REMOTE ALARM LIGHT <br /> 13a CIRCUIT NUMBER AND CONTROL ZONE 7_ FOR EXISTING HVAC UNITS SCHEDULED TO REMAIN OR TO BE �/ <br /> #1'� DIV DIVISION 10 0T. O N <br /> EOL END OF UNE DEVICE RELOCATED REFER To MECHANICAL ORAWINCsS. Z <br /> BRANCH CIRCUIT WIRING.ARROW INDICATES HOME RUN TO PANEL !} N W 0' <br /> WITH CIRCUITS AS NOTED.WIRE IS AWG MINIMUM UNLESS DWG' DRAWING ^ (10 <br /> B-27,29,31 NOTED OR SCHEDULED OTHERWISE SHORT TICK MARKS INDICATE SWITCHES ® SPRINKLER SYSTEM PRESSURE SWITCH <br /> PHASE CONDUCTORS.LONG TICK MARKS INDICATE NEUTRAL ELEC ELECTRIC < <br /> ® FIRE DOOR RELEASING DEVICE CONNECTION [Z <br /> CONDUCTORS.DOT INDICATED GROUND CONDUCTOR.D07TE0 GENERAL ELECTRICAL NOTES: i=U O Lug�: <br /> HASH MARK INDICATES-WLATED GROUND-(GREEN INSULATION a SINGLE POLE SWTTCH(LOWVO.TAGE DIMMER SWITCH EMT ELECTRICAL METALLIC TUBING <br /> WITH YELLOW STRIPE)CONDUCTOR ONLY BRANCH CIRCUIT HOME L 0 ON 7ANE'a•S.H MM) )� SPRINKLER LC'NAIR ALARA CONNECTION Z <br /> EXST EXISTING 1. ASSUME ALL CORRIDOR AND HAWWAY WALLSARE FIRE RATED c Q <br /> RUNS ARE WOK-ATED WITH CONDUCTOR COUNT.SEE GENERAL SUBSCRIPT: 2 2-POLE (E) ;G Q <br /> ELECTRICAL NOTES 3 THREE-WAY SWITCH ® FIRE ALARM RELAY CONSJRUCTION �: <br /> FA FIRE ALARM BRANCH CIRCUIT NOTES: �j <br /> 4 FOUR-WAY SWITCH _ i'--LL] <br /> WIRING CONCEALED IN COILING OR WALL CONTROL(LOWERCASE)DESIGNATION <br /> AIRE i O U [� <br /> CASTER OVEREDES RITC ON FC FOOTCANDLE <br /> i' <br /> WRING CONCEALED BELOW RDDR DR GR.40E MO MASTER OVERRIDE SWITCH REMODEL A CPII.Y BRANCH CIRCUIT HOMEP.UNS INDICATE CONDUCTOR COUNT 1,, w <br /> LV LOW VOLTAGE SWITCH FLA FULL LOAD AMPS IF MORETHAN TWOWIRECIRCUITPLUSGP.OUND.CONTINUEWIP.E J W <br /> WI?INGEXPOSED D DIMMER SWITCH COUNT TO OUTLETS AS REQURIDTO PROVIDE INDICATED PHASE, T— Q w <br /> HOMERLIN OS OCCUPANCY SENSORISMTCH HEAVY LMEWEIGFIT=NEW V4DRK FLEX FLEXIBLE CONDUIT NEUTRAL,AND ECU PMENT GROUND CONDUCTORS PER CODE00 <br /> - ] GALV GALVANIZED <br /> O <br /> ® CEILING MOUNTED OCCUPANCY SENSOR (2X4LAVIN SHOWNBASED ON CIRCUIT DESIGNATIONS INDICATED. ,W= <br /> CCAJDUR Up.DOWN SUBSCRIPT: P=PASSIVE INFRARED C.LIGHTING SHALL BE 410 AWG u) <br /> LIGHT LINE WEIGHT=EXISTING TO REMAIND=DUAL TECHNOLOGY GNO GROUND <br /> FLDOBLE WIRING CONNECTION U=ULTRASONIC.369 DEG RANGE (RECEPTACLE SHOWY) D.PROVIDE SEPARATE NEUTRAL CONDUCTOR FOR BRANCH ILLI <br /> H=ULTRASONIC,HALLWAY PATTERN 'r;(E) HP HORSEPOWER CIRCUITS SERVING RECEPTACIEOUTLETSAND LIGHTING UNLESS )1 <br /> —� CONDURIWIRINGSNIDBBOUT WITH END CAP OR ®-i WALL MOUNTED OCCUPANCYSFINSOOTHERMSE INDICATED <br /> R �W W <br /> INSULATED PLASTIC BUSHING SUIBSCRIPT: ab-DUALRELAY WITH TWO INTEGRAL'OFF' ELECTRICAL HVAC HEATING,VENTILATION B AIR CONDITIONING E PROVIDE MANUFACTURER APPROVED PIN INSERT STYLE HANDLE r L <br /> SWITCHES DEMOLITION(RECEPTACLE SHOWN) TIES BETWEEN SINGLE POLE CIRCUIT BREAKERS SERVINGSRANCH j > I� <br /> CONDURlWIRING CONTINUATION J-BOX JUNCTION BOX CIRCUITS SHARING A COMMON NEUTRAL O <br /> ® <br /> DAYLIGHT SENSOR <br /> GROUNDING POINT SUBSCRIPT: D-CONTINUOUSDIMMING KVA KILOVOLT AMPERES 3. MINIMUM CONDUIT SIZE FOR HOMERUNS AND FOR CONDUIT <br /> S-SWITCHED INSTALLED BELOW GRADE OUTDOORS SHALLBEW4 INCH. <br /> IC`N KILOWATTS <br /> ANNOTATIONS EXTERIOR PHCELL q. PRIOR OTOTO BID REFER TO GENERAL SHEETS(3.1 AND G3.2 FOR <br /> e SUBSCRIPT. D-CONTINUOUS DIMMING L?G LIGHTING ADDRION&ELECTRICALSOOPE PRIOR TO ROUGH-IN REPORT <br /> 3-SWTTCHED CONFLICTS TO ENGINEER FOR RESOLUTION. - STAMP <br /> MAX MAXIMUM O FEEDER CALLOl1T X-Y-L SEE SCHEDULE. SWITCH S. VERIFYSACK BOX RECKAREMENTS OF ROLIIPMENT FURNISHED UR Syss,A, <br /> SUBSCRIPT: F MECHAFAN NICATCHL <br /> UNDER OTHER THAI)DIVISION 25 SECTIONS AND EQUIPMENT .�,�^R vadti �' <br /> T MECHANICAL DMESWITCIi MCA MINIMUM ORCUR AMPS lam" ,�a <br /> # DETAIL SYMBOL (rS MDIGATE00N ORANJINGS) EL CIRCUITB FURNISH-FD BY OWNER. C <br /> RFARD(E EVA PADLOCKING ./ {. <br /> e #-IDENTIFYING NUMBER HANDLE GUARD(ELEVATOR LIGHTS) A1CM or KCM THOUSAND CIRCULAR MIL$ <br /> B•SHEET WHERE DETAIL SHOWN M MANUAL MOTOR STARTER <br /> OS OCCUPANCY SENSORISWITCH I MDF MAIN DISTRIBUTION FRAME <br /> # SECTION SYMBOL (AS INDICATED ON DRAtdEGH MECHANICAL <br /> WINGS) °ep LLWttO't <br /> B #-IDENTIFYING NUMBERMIN MINIMUM SIGNED <br /> B-SHEErV%HERE SECTION SHOWN OUTLETS AND CONNECTIONS MCP or:OCP MAXIMUM OVERCURRENT PROTECTION JUN <br /> 3 n LU ry^i6 PROJECT NQ�e <br /> Q <br /> DRAWING REVIS-CNSYMBOLJU; _. <br /> A.IDENTIFYING NUMBER DUPLEX RECEPTACLE QNEMA 5-2DR) MTG MOUNTING <br /> ® <br /> SHEET 140TE TAG SYMBOL: 2015.170 <br /> N or NEUT NEUTRAL ER�TT <br /> CITY 0 F' E <br /> GFCIDUPLEX RECEPTACLE(NEMA S-2pZ) ,SWM ,CUED <br /> #-IDENTIFYING NUMBER , <br /> NTS NOTTC SCALE 1. <br /> MECHANICAL EQUIPMENT CALL DUI- ® FLOOR BOX(DUPLEXRECEPTACLE SHOWN) Permit - AD CTU <br /> ## EOIIIPMENTCALL OIIT DC ONCENTER Services <br /> O (R� INDOOR SERVICE POLE Oor PH PHASE !DATE <br /> oala X15 <br /> Q <br /> JUNCTION BOX <br /> FNL PANEL <br /> DIAGRAMS MOTOR CONNECTION REC RECEPTACLE REVISIONS <br /> ® EQUIPMENT CONNECTION RM ROOM Qp 02.22.16 ORIGINAL <br /> BIDSET <br /> ADDENDUM <br /> CIRCUIT BREAKER SHT SHEET <br /> SCHEDULED EWIPMINT CONNECTIQ!OFR SYMBOL <br /> f— <br /> DISCONNECT SWITCH (INCLUDES FEEDER,DIS.'ONNECT,STARTER,AND STD STANDARD <br /> FUSED DISCONNECT SWITCH OTHER REQUIREMENTS AS SCHEDULED, SW SWITCH <br /> )O C(-XP SUBSCRIPT: XXA-SWITCH AMPERE RATING &RHD SWITCHBOARD <br /> (XX A)-FUSE AMPERE RATING <br /> XP-NUMBEROFPCLES ® CEILING MOUNTED PRCJCCTOR TV TELEVISION ..... .. <br /> PX% ® TTB TELECOMMUNICATIONS TERMINAL BOARD ' <br /> ELECTRICAL PANEL CEILING RECESSED RECEPTACLE 'TITLE <br /> TYP TYPICAL ELECTRICAL INDEX SHEET: <br /> CEILING SPEAKER iELECTRICAL <br /> UL UNDERWLRITERSLABORATORY BOA ELECTRICAL LEGEND AND NOTES ':.LEGEND <br /> rT TRANSFORMER V VOLTS E3.1 IST FLOOR•PCA'ERPLAN !AICD NOTES <br /> GROUNDED WYE CONNECTION TELECOMMUNICATIONS VA VOLTAMPERES E31 2ND FLOOR-POWER PLAN <br /> O LITILry COMPANY METER VFD VARIABLEFREGUF14CY DRIVE <br /> E33 ELECTRICAL ROOF PLAN <br /> ' I7TE)TELECOMMUNIOATICNSTERM INAL BOARD <br /> CURRENT TRANSFORMER(CT) W WATTS E5.1 ONE4JNE DISTRIBUTION DIAGRAM ?SHEET <br /> ' E0.1 <br /> WAP CFJU(JG MOUNTED WIRELESS ACCESS POINT <br /> WP WEATHERPROOF F..I ELECTRICAL SCHEDULES <br /> ELEI <br /> AN WII U.2 ELECTRICAL.SCHEDULES <br /> W/o WITHOUT 1 ISSUED FCR <br /> REBID SET <br /> XFMR TRANSFORMER <br /> 0 r <br /> 1000 <br /> S SN'Ei a¢l5'cUE f.�:E y.1:EN <br /> wolro %VQ% 4mk 1 , 0 <br /> VT <br /> � VTC/e LR;c.tEPIAYEs?S Y.�ED !I <br /> Provided to eutlderr aebange of WA,Pne,rez ge wMftrmr Agtt emt roe vvv.bava.com-Alvays Ve_ify scale <br />
The URL can be used to link to this page
Your browser does not support the video tag.