My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2617 VIRGINIA AVE 2017-07-28
>
Address Records
>
VIRGINIA AVE
>
2617
>
2617 VIRGINIA AVE 2017-07-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2017 1:26:26 PM
Creation date
7/17/2017 11:30:03 AM
Metadata
Fields
Template:
Address Document
Street Name
VIRGINIA AVE
Street Number
2617
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
80
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PUBL/c WORKS <br /> January 22, 2013 <br /> Sharon Capps <br /> 16625 41st Dr NE #A <br /> Arlington WA 98223 <br /> Subject: Project: Capps <br /> Job Address: 2617 Virginia Ave <br /> Plan Check No: CW1301-002 <br /> Dear Ms. Capps: <br /> In response to your application for a construction permit, your plans have been examined and <br /> you are advised that the issuance of a permit is being withheld for the reasons listed below. <br /> These comments address building issues only. Additional revisions or additions may be <br /> required by other departments (such as Utilities, Planning or Fire). All references refer to the <br /> (2009 International Building Code,) (2009 International Residential Code,) as amended by the <br /> State of Washington and/or Washington State Energy Code 2009 Edition, and adopted by the <br /> City of Everett, unless stated otherwise. <br /> In order for the processing of your application to continue, it will be necessary to <br /> provide the Building Division with two new complete sets of drawings reflecting the <br /> corrections requested. <br /> 1. Typical existing wall section shows 2x10 joists sitting on a 2x P.T. sill. The existing <br /> house is 2x8 joists sitting on a 6x6 beam. Please clarify. Show connection of 6x6. <br /> 2. R-30 insulation in the floor will not fit in a 2x8 joist cavity. <br /> 3. Building Section A-A does not show proposed "4x10 (UP)" beam supporting ceiling joists <br /> and the ridge. Please show how ceiling joists are supported if beam is "up". <br /> 4. Show how"(E) 2x10 floor joists at 16"O.C."are supported at the"5 1/8"x10 1/2"GLB". <br /> 5. Call out hangers used for existing floor joists at the "4x12 (UP)" beams shown on upper <br /> floor framing plan. <br /> 6. Show location of water heater. <br /> 7. Show how dwelling is provided with heat. <br /> S. One foundation vent shall be located within 3'-0"of all corners. Show on plans. <br /> CITY OF EVERETT• 3200 Cedar Street • Everett, WA 98201 • (425) 257-8800 • Fax (425) 257-8882 <br />
The URL can be used to link to this page
Your browser does not support the video tag.