Laserfiche WebLink
CW", <br /> DESIGN, INC. <br /> P.O. Box 476 • RENTON, WA. 9B❑57 <br /> 425-271 -OOB2 (OFFICE) • 425-22B-8699 (FAX) <br /> February 5, 2013 <br /> Plan Review City of Everett <br /> 3200 Cedar St �Ip <br /> Everett, WA 98201 <br /> a <br /> J FEB 2 2 2013 <br /> Attn: Jeff Heilman, Development Technician <br /> CITY OF EVERE !T <br /> Subject: Sharon Capps POrrrsi# <br /> 2617 Virginia Ave "`�"""`°"." ""�," `�- --.• <br /> Everett, WA <br /> Plan Check No: CW1301-002 <br /> Dear Mr Heilman, <br /> Listed below are the city correction responses referenced in accordance with your item numbers. <br /> Item #1 The existing 6x6 beam below the main floor joists will be removed and the existing joists will set <br /> on a new mud-sill plate per the engineered details (sheet A2.0). <br /> Item#2 Added 2x2 to the existing 2x8 joists and specified high density R-30 insulation, 8-1/4"thick <br /> (sheet A2.0). <br /> Item#3 Added Simpson U210 joist hangers (sheet A3.0). <br /> Item #4 Added note to sheet for joists to set on top of new glb (sheet A3.0). <br /> Item #5 The 4x12 in question will be dropped underjoists. No hangers required (sheet A3.0). <br /> Item #6 Added water heater to lower floor level (sheet A2.0). <br /> Item#7 Added furnace to lower floor level (sheet A2.0). <br /> Item #8 Added measurements to main floor framing plan for crawl space vent locations at corners <br /> (sheet A2.0). <br /> Item#� Added crawl space access t0 the main flOOr plan (sheet A3.0). <br />