My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4916 VISTA PL 2017-07-28
>
Address Records
>
VISTA PL
>
4916
>
4916 VISTA PL 2017-07-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2017 2:32:07 PM
Creation date
7/17/2017 11:43:48 AM
Metadata
Fields
Template:
Address Document
Street Name
VISTA PL
Street Number
4916
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
71
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WASHINGTON STATE ENERGY CODE, RESIDENTIAL PROVISIONS <br /> TABLE 406.2 <br /> ENERGY CREDITS(DEBITS) <br /> OPTION DESCRIPTION CREDIT(S) <br /> la EFFICIENT BUILDING ENVELOPE la: 0.5 <br /> Prescriptive compliaj=is based on Table R402.1.1 with the following modifications: <br /> Fenestration U. 0.28 <br /> Fl -38 <br /> Slab <br /> o e R-10 perimeter and under entire slab <br /> Below grade slab R-10 perimeter and under entire slab <br /> or <br /> Compliance based on Section R402.1.4: Reduce the Total UA by 51/o. <br /> 1 b EFFICIENT BUILDING ENVELOPE Ib: 1.0 <br /> Prescriptive compliance is based on Table R402.1.1 with the following modifications: <br /> Fenestration 11:0.25 <br /> Wall R-21 plus R-4 <br /> Floor R-38 <br /> Basement wall R-21 int plus R-5 ci <br /> Slab on grade R-10 perimeter and under entire slab <br /> Below grade slab R-10 perimeter and under entire slab <br /> or <br /> Compliance based on Section R402.1.4: Reduce the Total UA by 15%. <br /> I EFFICIENT BUILDING ENVELOPE 1 c: 2.0 <br /> Prescriptive compliance is based on Table R402.1.1 with the following modifications: <br /> Fenestration U:0.22 <br /> Ceiling and single-rafter or joist-vaulted R-49 advanced <br /> Wood frame wall R-21 int plus R-12 ci <br /> Floor R-38 <br /> Basement wall R-21 int plus R-12 ci <br /> Slab on grade R-10 perimeter and under entire slab <br /> Below grade slab R-10 perimeter and under entire slab <br /> or <br /> Compliance based on Section R402.1.4: Reduce the Total UA by 30%. <br /> 2a AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION 2a 0.5 <br /> Compliance based on R402.4.1.2: Reduce the tested air leakage to 4.0 air changes per <br /> hour maximum <br /> and <br /> All whole house ventilation requirements as determined by Section M 1507.3 of the <br /> International Residential Code shall be met with a high efficiency fan(maximum 0.35 <br /> watts/cfm),not interlocked with the furnace fan ventilation systems using a furnace <br /> including an ECM motor are allowed,provided that they are controlled to operate at <br /> low speed in ventilation only mode. <br /> To qualify to claim this credit,the building permit drawings shall specify-the option <br /> being selected and shall specify the option being selected and shall specify the <br /> maximum tested building air leakage and shall show the heat recovery ventilation <br /> system- <br /> L/ <br />
The URL can be used to link to this page
Your browser does not support the video tag.