5a EFFICIENT WATER HEATING 5a: 0.5 <br /> Water heating system shall include one of the following: <br /> Gas,propane or oil water heater with a minimum EF of 0.62 <br /> or <br /> Electric water heater with a minimum EF of 0.93. <br /> and for both cases <br /> All showerhead and kitchen sink faucets installed in the house shall be rated at 1.75 <br /> GPM or less.All other lavatory faucets shall be rated at 1.0 GPM or less_b <br /> To qualify to claim this credit,the building permit drawings shall specify the option <br /> being selected and shall specify the water heater equipment type and the minimum <br /> equipment efficiency and shall specify the maximum flow rates for all showerheads, <br /> kitchen sink faucets,and other lavatory faucets. <br /> 5b EFFICIENT WATER HEATING 5b: 1.5 <br /> Water heating system shall include one of the following: <br /> Gas,propane or oil water heater with a minimum EF of 0.82 <br /> or <br /> Solar water heating supplementing a minimum standard water heater.Solar water <br /> heating will provide a rated minimum savings of 85 therms or 2000 kWh based on the <br /> Solar Rating and Certification Corporation(SRCC)Annual Performance of OG-300 <br /> Certified Solar Water Heating Systems <br /> or <br /> Electric heat pump water heater with a minimum EF of 2.0 and meeting the standards <br /> of NEEA's Northem Climate Specifications for Heat Pump Water Heaters <br /> or <br /> Water heater heated by ground source heat pump meeting the requirements of Option <br /> 3c. <br /> To qualify to claim this credit,the building permit drawings shall specify the option <br /> being selected and shall specify the water heater equipment type and the minimum <br /> equipment efficiency and,for solar water heating systems,the calculation of the <br /> minimum energy savings <br /> 6 RENEWABLE ELECTRIC ENERGY: 0.5 <br /> For each 1200 kWh of electrical generation provided annually by on-site wind or solar <br /> equipment a 0.5 credit shall be allowed,up to 3 credits.Generation shall be calculated <br /> as follows: <br /> For solar electric systems,the design shall be demonstrated to meet this requirement <br /> using the National Renewable Energy Laboratory calculator PV WATTS. <br /> Documentation noting solar access shall be included on the plans. <br /> For wind generation projects designs shall document annual power generation based <br /> on the following factors: <br /> The wind turbine power curve;average annual wind speed at the site;frequency <br /> distribution of the wind speed at the site and height of the tower. <br /> To qualify to claim this credit,the building permit drawings shall specify the option <br /> being selected and shall show the photovoltaic or wind turbine equipment type, <br /> provide documentation of solar and wind access,and include a calculation of the <br /> minimum annual energy power production. <br /> a. Interior Duct Placement.Ducts included as Option 4 of Table R406.2 shall be placed wholly within the heated <br /> envelope of the housing unit.The placement shall be inspected and certified to receive the credits associated with this <br /> option. <br /> Exception: Ducts complying with this section may have up to 5%of the total linear feet of ducts located in the <br /> exterior cavities or buffer spaces of the dwelling.If this exception is used the ducts will be tested to the following <br /> standards: <br /> Post-construction test: Leakage to outdoors shall be less than or equal to I CFM per 100 ft of conditioned floor <br /> area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the <br /> manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. <br /> b. Plumbing Fixtures Flow Ratings.Low flow plumbing fixtures(water closets and urinals)and fittings(faucets and <br /> showerheads)shall comply with the following requirements: <br /> I. Residential bathroom lavatory sink faucets: Maximum flow rate-3.8 Umin(1.0 gal/min)when tested in <br /> accordance with ASME A112.18.1/CSA B125.1. <br /> 2. Residential kitchen faucets: Maximum flow rate-6.6 L/min(1.75 gal/min)when tested in accordance with <br /> ASME A112.18.I/CSA B125.1. <br /> 3. Residential showerheads: Maximum flow rate-6.6 L/min(1.75 gal/min)when tested in accordance with ASME <br /> Al 12.18.1/CSA B125.1. <br />