My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2523 WETMORE AVE 2017-07-31
>
Address Records
>
WETMORE AVE
>
2523
>
2523 WETMORE AVE 2017-07-31
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2017 7:54:01 AM
Creation date
7/17/2017 2:30:30 PM
Metadata
Fields
Template:
Address Document
Street Name
WETMORE AVE
Street Number
2523
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r <br /> INVESTIGATIVE <br /> ENGINEERS, LLC <br /> RESPONSIVE • ACCURATE • THOROUGH <br /> November 20,2012 <br /> Mr.Jeff Heilman, <br /> Engineering&Public Services Department <br /> City of Everett <br /> 3200 Cedar Street <br /> Everett,WA 98201 <br /> RE: Responses to the Building Review Comments for the Brownfield Fire Restoration at 253 Wetmore <br /> Ave, Everett,WA 98201.; Permit Number CW1210-006; BCIE Job No. 12151 <br /> Dear Mr. Heilman, <br /> BC Investigative Engineers (BCIE) has reviewed your plan review comments completed for the above <br /> referenced permit submittal. The revised permit submittal set is provided for your review and approval and <br /> is based on your review comments. The following is a list of itemized responses to your comments: <br /> Correction#1: <br /> The overhangs on both the north and south side of the building have been removed. The plans and details <br /> on sheets A1.0,A1.1, S3.0 &S4.0 have been modified to show this change. <br /> orrections #2: <br /> o erungs on the north and side exterior walls are existing openings and are not being modified. The two <br /> windows on the upper floor unit on the north and south side are being replaced due to fire damage, but are <br /> not being increased in size. <br /> Corrections #3: <br /> As discussed over the phone the trusses that are being provided are tail bearing trusses. The truss designer <br /> has designed a single 2x12 top chord at the vaulted ceilings. R-38 compressed insulation with a thickness of <br /> 10.25" per the manufacturer will be in the 2x12 rafter cavity, which allows for the required 1" min air space <br /> above the insulation. Details A& C on sheet A1.1 have been modified to show these changes. <br /> ��tilations <br /> and calculations on sheet A1.1 have been modified due to the removal of the <br /> overhangs and soffits. <br /> 3605 C STREET NORTHEAST • AUBURN, WASHINGTON • 98002 <br /> OFFICE 253.833.5557 • FAX 253.833.7309 <br /> \1'\C'\V.BCIE.NET <br />
The URL can be used to link to this page
Your browser does not support the video tag.