My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3025 LOMBARD AVE 2017-08-02
>
Address Records
>
LOMBARD AVE
>
3025
>
3025 LOMBARD AVE 2017-08-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/2/2017 8:22:35 AM
Creation date
8/2/2017 8:22:18 AM
Metadata
Fields
Template:
Address Document
Street Name
LOMBARD AVE
Street Number
3025
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
88
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
j,,. <br /> �[��`� <br /> ENG/NEE/t/NG/ PUBL/L 5E%!///CES DEP'A!�'TiNENT <br /> `' '�, � <br /> uy , <br /> Mr. Ruben Sanchez <br /> 3201 Cedar St. <br /> Everett WA 98201 <br /> RE: Owner: City of Everett <br /> Job Address: 3205 Lombard Ave <br /> Plan Check No: B0907-034 <br /> Dear Ruben; <br /> In response to your application for a construction permit, your plans have been examined and you <br /> are advised that the issuance of a permit is being withheld for the reasons listed below. These <br /> comments address buildinb issues only. Additional revisions, or additions, may bc required by <br /> other departments (such as Utilities, Planning or Fire). All references refer to the 2006 International <br /> Building Code, as amended by the State of Washington and adopted by the City of Everett and the <br /> Washington State Energy Code, 2006 Edition, unless stated otherwise. <br /> In order for the processing of your application to continue, it will be necessary to provide tlie <br /> Building Division with two complete ne«- sets of construction documents reflecting the <br /> corrections requested. <br /> 1. Everett Municipal Code, Chapter 16.01.040, requires elevator cars to "be of such size and <br /> arrangement to accommodate a 24-inch by 84-inch ambulance stretcher in the horizontal, <br /> open position and shall be identified by the International symbol for Emergency Medical <br /> Services (Star of Life). Tt�e symbol shall not be less than 3 inches high and shall be place <br /> inside on both sides of the hoistway door frame". <br /> 2. IBC 3006.4 requires the door into the elevator machine room to have a fire-protection rating <br /> of not less than that required for the hoistway enclosure doors. <br /> If you have any questions, please call me at 425-257-7264. <br /> Please prepare a response letter showing where each item in this correction letter is addressed on the <br /> plan set. <br /> Upon resubmittal of the drawings, your application will be given priority and plan review will <br /> recommence. <br /> All required submittals shall be of sufficient detail and contain sufficient information to ensure that <br /> the proposed structure will be constructed in compliance with all adopted codes. <br /> Sincerely, <br /> � <br /> Steve Miller <br /> Associate Engineer <br /> kathy/miller/60907-034(3205 Lmnbard Ave) <br /> CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 • (425) 257-8800 • Fax (425) 257-8856 <br />
The URL can be used to link to this page
Your browser does not support the video tag.