My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3025 LOMBARD AVE 2017-08-02
>
Address Records
>
LOMBARD AVE
>
3025
>
3025 LOMBARD AVE 2017-08-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/2/2017 8:22:35 AM
Creation date
8/2/2017 8:22:18 AM
Metadata
Fields
Template:
Address Document
Street Name
LOMBARD AVE
Street Number
3025
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
88
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2006 Washington State Nonresidential Energy Code Compliance Form <br /> • � - • . • <br /> 2006 Washington State Nonresidentiai Energy Code Compliance Forms Revised July 2007 <br /> � Decision Flowchart Use this flowchart to determine if project qualifies for the optional Prescriptive Option. <br /> for Prescriptive Option If not,either the Component Performance or Systems Analysis Options must be used. <br /> 1302 Space Heat Type:For the purpose of determining building envelope Electric Resistance:Space heating systems which use electric resistance <br /> requirements,the following two categories comprise all space heating types: START elements as the primary heating system including baseboard,radiant,and <br /> Other:All other space heating systems including gas,solid fuel,oil,and forced air units where the total electric resistance heat capacity exceeds 1.0 <br /> propane space heating systems and those systems listed in the exception to W/ftZ of the gross conditioned floor area. Exception:Heat pumps and <br /> electric resistance. (continued at right) terminal eleclric resistance heating in variable air volume distribution systems. <br /> Electric <br /> N Resistance Yes <br /> Heat? — <br /> All Insu�ation Installed? All Insulation Installed? <br /> Below Grd Wall(e�) R-10 Wood Metal <br /> Below Grd Wall(oth) R-19 Below Grd Wall(ext) R-10 R-10 <br /> Roof Over Attic R-30 Below Grd Wali(oth) R-19 U-0.062 <br /> All Other Roof R-21 Roof Over Attic R-38 U-0.031 <br /> Raised Fioor R-79 All Other Roof R-30 U-0.034 <br /> Slab-On-Grade R-10 Raised Floor R-30 U-0.029 <br /> Radiant Floor R-10 Slab-On-Grade R-10 R-10 <br /> Opaque Door U-0.60 Radiant Floor R-10 R-10 <br /> O a ue Door U-0.60 U-0 60 <br /> No Yes Yes N <br /> Mass Wall Above Grade G Wall R1 Mass Wall <br /> —N Criteria OK? N wood,or No Criteria OK? No-► <br /> (below) Wall R19 0.062 met <br /> (below) <br /> Yes Yes <br /> Yes Yes <br /> AG Mass Wall Insulation Req. AG Mass Wall Insulation Req. <br /> Mass Wali U0.15/R5.7ci Mass Wall U0.15/R5.7ci <br /> CMU Block Ins.Cores ye�_CMU Block Ins.Cores <br /> Wood Frame R19 Wood Frame R19 <br /> Metal Framed R19 e Metal Framed U0.062 <br /> No Glazing Criteria Met? Glazing Criteria Met? No <br /> Giazing Vert OH Glazing Vert OH <br /> Area°/ UVaI UVaI SHGC Area% UVaI UVaI SHGC <br /> 0-30% 0.55 0.70 0.45 0-30% 0.40 0.60 0.40 <br /> 30-45°/a 0.45 0.60 0.40 >30 Not Allowed <br /> >45% Not Aliowed <br /> No Yes Prescriptive , Y?S No <br /> Path Allowed <br /> Component Performance, <br /> Systems Analysis, or - - - - <br /> EnvStd Required <br /> Concrete/Masoruy Option'� Wall Heat Capacity (HC) weighted heat <br /> Assembly Description Assy.Tag HC*` Area(s� HC x Area capacity(HC)of <br /> the total above <br /> grade wall is a <br /> minimum of 9.0, <br /> the Concrete <br /> Masonry Option <br /> may be used. <br /> "For framed <br /> walls,assume <br /> HC=1.0 unless <br /> calculations are <br /> provided;for all <br /> other walls,use <br /> Totals Section 1009. <br /> Area weighted HC:divide total of(HC x area)by Total Area <br /> � �l�� <br />
The URL can be used to link to this page
Your browser does not support the video tag.